In May 2022, Omron Automation (China) Co., Ltd.'s new product [Miniature Connector Terminal Block XW2K Series] was officially released. The more compact size saves space in the control cabinet, reduces the number of man-hours, and gives the control cabinet a new value!
When it comes to the space footprint of your control cabinet, do you have any of these concerns:
● In the face of increasing performance requirements, the space for expansion is stretched
● The size of the control cabinet was specified, and the footprint had to be further reduced
Revolutionizing the manufacturing process of control cabinets
Giving new value to the control cabinet
Omron has adopted the common concept of "Value Design for Panel" (hereinafter referred to as "Value Design") for the product specifications in the control cabinet, and combined with the product portfolio that supports Value Design, the control cabinet design and manufacturing process has been integrated with more user-friendly details, and the control cabinet has been created with a rich product lineup to create a more user-friendly and future-oriented control cabinet, further enhancing the value of the control cabinet.
Connector terminal blocks XW2K series have been added
Further space savings in the control cabinet
Omron's newly released [Miniature Connector Terminal Block XW2K Series] has a smaller size and a two-way installation method, which can effectively use the existing space, make room for functional expansion parts, and realize the miniaturization of the control cabinet! In addition, the use of Push-In Plus terminal blocks reduces wiring man-hours compared to conventional screw terminals, and makes screws maintenance-free without slackening, contributing to the reduction of terminal block miniaturization and wiring efficiency.
Save installation space and increase performance
◾ The Connector Terminal Blocks based on Value Design for Panel enable smaller size*1 and bidirectional installation. Reduction of ineffective space, miniaturization of control cabinets, and improvement of device performance without increasing size.
Shorten the production cycle of control cabinets
◾ The entire process of control cabinet production can be shortened by selecting tools and unique product specifications through the web.
01. Design
You can easily select the right terminal block and cable for your PLC via the web.
02. Assembly/wiring
The power cord is equipped with a common terminal, which saves wiring by transverse conduction of the power supply.
The Push-In Plus terminal block can be used in a single step, significantly reducing wiring man-hours (approx. 60%*1).
03. Factory/operation
The Push-In Plus terminal block secures the terminals/wires with a spring-loaded structure, so that the screws will not loosen or fall off due to vibration, so there is no need for tightening.
◾ There is no need to rewire the vertically mounted models, and additional I/O can be added by simply rotating to make room.
Reduce wiring load
◾ With Push-In Plus Terminal Blocks & Front In/Front Out, wiring can be done quickly and easily without the need for a technician.
◾ Hands-free, easy wiring
◾ The terminal arrangement is easy to identify, improving the efficiency of wiring work.
◾ Tool-free disassembly and assembly of terminal blocks allows for easy wiring directly by hand, making it easy to wiring in a variety of locations.
By innovating the control cabinet manufacturing process and creating a rich product lineup, Omron is providing solutions to the problems that exist in the production of control cabinets, and solving the difficult problems of saving space and reducing man-hours for customers with the XW2K series of small connector terminal blocks.
|
More on that
|
Introduction to Omron electronic thermometer and how to use it
Using an Omron electronic thermometer, which is displayed digitally and compared with a conventional thermometer, there is a small chance of error, generally no more than 0.1 degrees, so there is little need to worry about inaccuracies. Every time you use it, it's also very simple, just press the power switch ...
|
|
Omron Liang brings the latest seventh-generation FORPHEUS to the stage of the Expo
The 5th China International Import Expo (hereinafter referred to as the "Expo") will officially kick off on November 5. As a global expert in digital transformation in the field of automation, Omron will attend the appointment for the fifth time and bring new digital intelligence technologies and solutions to show its continuous focus on social development.
|
|
Recommended selection of Omron's commonly used products
Omron's recommended product models today:
K8DS is a triple opposite missing sequential appliance
The inverse lacks sequential electrical appliances
Three-phase voltage + inverted phase lack sequential electrical appliances
Three-phase unbalanced + inverted lack of sequential electrical appliances
Three-phase undervoltage + inverted inverted missing sequential electric
Three-phase voltage + three-phase ...
|
|
Omron PLC's maintenance process and technical requirements
(1) When measuring voltage, it is necessary to use a digital voltmeter or a universal meter with an accuracy of 1%.
(2) The power supply rack and CPU motherboard can only be removed when the main power supply is cut off;
(3) Before the RAM module is removed from the CPU or plugged into the CPU, the power supply of the PC should be disconnected.
|
|
Omron products are used in fully automated high-speed sewing and cutting
Process introduction
The sewing and cutting line is mainly used for sewing and cutting shirt collars, sleeves and pockets, and the equipment is divided into the following 4 parts:
1. Discharging part: used for the initial positioning of sewing materials, the laser projection position is controlled by the motor, and the materials are manually placed on the platform.
|
|
Common troubleshooting methods for Omron relays
First, the contact point is loosened and cracked
The contact point is the electrical contact part of the Omron relay to convert the load, and the contact point of some products is matched with each other by riveting pressure, and the key disadvantage is that the contact point is loose, the contact point is cracked or the error of the standard part is too large. This will jeopardize the relay ...
|
|
How to add SMC module to Omron plc
After adding the I/O module, you need to set it in the CX-PROGRAMMER program.
Find the IO table and unit settings, double-click to find the mainframe [0000], dot + sign, and then double-click 00 (if not set), 00 represents the module number closest to the CPU.
|
|
【Omron industry case】Application case of laser die-cutting machine for secondary battery
Process introduction
In the traditional die-cutting process, because the cutter cannot cut the material completely, the connecting frame will be left, which increases the cost of the material. In addition, the service life of the die-cutting knife is 1 million times, such as long-term continuous operation, it needs to be replaced and maintained in time, and the maintenance and debugging time is also very long.
|
|
Omron attended the 2022 P&G Electrical Automation Symposium
Recently, the 2022 P&G Electrical Automation Seminar held by Procter & Gamble (China) Co., Ltd. (hereinafter referred to as "P&G") was held in Guangzhou. Omron Automation (China) Co., Ltd. (hereinafter referred to as "Omron") was invited to attend the meeting and worked with the engineering, manufacturing, R&D and other departments of P&G factories on behalf of the ...
|
|
Introduction to the wiring steps of Omron switch relays
1. Before connecting, determine the voltage required for the proximity switch, and if it is a 3-wire system, determine whether it is PNP type or NPN type. The proximity switch is divided into 2-wire, 3-wire and 4-wire systems.
2. When the wire system proximity switch is connected with the relay, it is in series form. i.e. the relay is connected to the proximity switch ...
|
|
The solution to the problem of Omron switches only turning on the green light
For the problem that the Omron photoelectric switch only lights green, it may be because a component on the circuit board is faulty or damaged, or because of the poor connection of a component on the circuit board.
So, to deal with this, the first thing to do is to see if the components on the board are ...
|
|
Precautions when using Omron switches
One. Omron switch in daily use, basically need to be used every day, when using Omron switch, you need to pay attention not to wet hand operation, to avoid electric shock accidents, and secondly, if the water vapor once invaded the inside of the switch line, it will cause internal damage to the switch, than ...
|
|
The Omron and BYD technical exchange meeting was held to explore the new future of intelligent automobile manufacturing
Recently, Omron Automation (China) Co., Ltd. (hereinafter referred to as "Omron") and BYD Co., Ltd. (hereinafter referred to as "BYD") successfully held a technical exchange meeting in Shenzhen. Omron industry and technical experts, BYD automobile, light rail, new energy, electronics ...
|
|
How does Omron PLC input the rising/falling edge?
The first
1. First of all, we open the CX-P software, set the PLC model, enter the programming section, and prepare for programming.
2. Usually when we program, we are used to entering LD instruction programming, when we need to input the rising edge, we need to enter @LD0.00, you can.
3. Down...
|
|
Application of Omron automatic gluing robot
Process introduction
Since the implementation of the [plastic restriction order] in 2007, plastic packaging has been greatly restricted. Subsequently, all kinds of metal cans represented by beer cans, tea cans, and oil cans are increasing, and metal packaging has begun to usher in a period of rapid development.
Metal cans are divided into ...
|
|
How to connect Omron plc IP address?
1. The IP address of the computer is automatically obtained.
2. The computer is directly connected to the PLC network port.
3. Open the DirectEthernetUtility software. Software Setup Start - > All Programs - > OMRON - >Communications Middleware Utilities - > DirectE...
|
|
What are the main items of Omron PLC overhaul?
1. Overhaul the power supply. It is possible to detect whether the voltage variation range is within the permissible ± 10% at the power terminal.
2. Working environment. Focus on checking whether the temperature, humidity, vibration, dust, interference, etc. meet the standard working environment.
3. Power supply for input and output. Available in the corresponding ...
|
|
The working principle and purpose of Omron relays
How it works
Add a certain voltage at both ends of the coil, a certain current will flow through the coil, thus producing an electromagnetic effect, and the armature will overcome the tensile force of the return spring under the action of electromagnetic force attraction and attract to the core, thereby driving the dynamic contact and static contact (normally open contact) of the armature ...
|
|
Omron's new E2EW series proximity sensors have the longest sensing range in the world
Hoffman Estates, Illinois, March 24, 2020 – Manufacturers in the automotive industry are trying to capitalize on the current trend toward electric vehicles and low fuel consumption by building lightweight vehicles and favoring aluminum over iron. With the inclusion of both iron and aluminum ...
|
|
Analysis of the causes of Omron S8 series switching power supply failures
1. Fault phenomenon: After powering on, the power supply does not respond.
2. Cause of failure:
(1) The input power supply voltage is insufficient and does not reach the specified range.
(2) The input power supply voltage is instantaneously impulsed, resulting in damage to the input components (such as fuses, rectifications, etc.) as shown in the figure: ...
|
|