Recommended selection of Omron's commonly used products

Create Date: 2024-8-30 12:03:23|Source: Omron/Omron

Omron's recommended product models today:

  K8DS is a triple opposite missing sequential appliance
Recommended selection of Omron's commonly used products
The inverse lacks sequential electrical appliances

Three-phase voltage + inverted phase lack sequential electrical appliances

Three-phase unbalanced + inverted lack of sequential electrical appliances

Three-phase undervoltage + inverted inverted missing sequential electric

Three-phase voltage + three-phase unbalance + inverse phase lack of sequential appliances

  P7 socket
Recommended selection of Omron's commonly used products
Finger touch protection type is available.

Fixed brackets and jumpers for PYF are available.

A new screwless series has been added.

  EE Photoelectric Sensor Accessories Connectors
       Recommended selection of Omron's commonly used products
Operation mode is equipped with ONW when shading is used and ON when light is in (switchable type)

High-speed response with a response frequency of 1kHz

The light entry indicator is clear for easy operation confirmation

The power supply voltage is DC5 - 24V wide range

It is equipped with a light type that turns on the light when shading

There are 8 types of shapes and types

Flex-resistant wires*2 are used as standard

  E3Z through-beam photoelectric sensor
       Recommended selection of Omron's commonly used products
Long-range/through-beam type 30m, regression reflective type 4m, diffusion reflective type 1m

The optical axis is easy to adjust and the deviation between the optical axis and the mechanical axis is controlled within ±2.5°

High stability/unique interference light avoidance algorithm

More on that
The interrupt function of Omron CP1 series PLC and the establishment of interrupt program The interrupt function of Omron CP1 series PLC and the establishment of interrupt program

Since the main program of the PLC is the working mode of cyclic scanning, some more urgent special tasks (interrupt subroutines) that occur randomly must be executed immediately without being affected by the scanning cycle, and the CPU temporarily aborts the main program and executes the interrupt subroutine, so the working mode is the interrupt function ...

What's the deal with Omron PLC without output voltage? What's the deal with Omron PLC without output voltage?

1. The indicator light at the output of the PLC is on, indicating that the DO point of the PLC has been closed; 、 2. The DO point of PLC is equivalent to a dry contact switch, imagine that an on/off switch on a line is closed, if you measure the voltage on both sides of this switch, there will be no voltage, thinking that the switch itself ...

How Omron PLC works and what are the advantages How Omron PLC works and what are the advantages

Omron PLC is a compact PLC with complete functions that provides highly additional machine control for industry-leading conveying and distribution control. It also has the ability to upgrade through a variety of advanced built-in boards, large program capacities and memory units for efficient software development in the Windows environment.

Introduction to the classification of Omron relay switch contacts Introduction to the classification of Omron relay switch contacts

1.A contacts A contact is a contact in which the two contact terminals are separated (OFF) when the switch is not operated, and closed (ON) when the switch is operated. If you want to start the load by operating the switch, you can use the A contact. A circuit is a circuit that uses a contact without operating the switch (pressing ...

The solution to the Omron blood pressure monitor E3 failure The solution to the Omron blood pressure monitor E3 failure

The E3 fault code usually appears on the display of the blood pressure monitor and indicates that the cuff is too tight or too loose. This failure can lead to inaccurate measurement results or even inability to complete the measurement. Solution(s): 1. Adjust the tightness of the cuff to make sure the cuff is neither too tight nor too loose. 2. Check the sleeve ...

A detailed description of the environment in which Omron sensors are used A detailed description of the environment in which Omron sensors are used

1. Ambient temperature The specification of the sensor will rule the ambient temperature range of the normal operation of the sensor, such as 40-85 degrees, which varies depending on the product model. It is advocated not to exceed the temperature range specified in the specification book, beyond the normal operating temperature range of the sensor, ...

How does Omron PLC input the rising/falling edge? How does Omron PLC input the rising/falling edge?

The first 1. First of all, we open the CX-P software, set the PLC model, enter the programming section, and prepare for programming. 2. Usually when we program, we are used to entering LD instruction programming, when we need to input the rising edge, we need to enter @LD0.00, you can. 3. Down...

How are Omron switch relays wired? How are Omron switch relays wired?

One. Before connecting, determine the voltage required for the proximity switch, and in the case of a 3-wire system, determine whether it is PP type or P type. The proximity switch is divided into 2-wire, 3-wire and 4-wire systems. Two. Wire proximity switches are connected in series when connected to relays. i.e. the relay is connected to the proximity switch to give it ...

Omron's new [Programmable Controller CP2E-ECT] was officially released Omron's new [Programmable Controller CP2E-ECT] was officially released

In December 2022, Omron Automation (China) Co., Ltd.'s new product [Programmable Controller CP2E-ECT] was officially released. The product is based on Omron's full research on the equipment needs of OEM customers in China, and is independently developed and produced by Omron China.

Introduction to Omron travel switches Introduction to Omron travel switches

Omron travel switch, position switch (also known as limit switch), is a commonly used small current master electrical appliance. Through the collision of the mechanical moving parts, the contact movement is realized, and the connection or disconnection of the control circuit is realized, so as to achieve a certain control purpose. Usually, this kind of switch is used to limit the ...

Routine maintenance of Omron PLC Routine maintenance of Omron PLC

1. The electrical control cabinet installed with PLC should have a clean and dry environment. Moisture-absorbing dry materials should be placed inside, and the splashing of coolant and oil mist should be prevented. 2. Regardless of the system working or shutdown, the electrical cabinet door should always be closed, and the electrical components should be kept in a good state.

The division of the storage area of Omron PLC The division of the storage area of Omron PLC

1. I/O relay area: there are 30 channels in total, and the address is 000-029. An idle relay or channel can be used as an intermediate relay. The rack slot number is from 007CH to 001CH from the left of the CPU unit. The I/O address number is represented by 5 digits: 1, single digit, ten digits indicate the relay ...

What are the main items of Omron PLC overhaul? What are the main items of Omron PLC overhaul?

1. Overhaul the power supply. It is possible to detect whether the voltage variation range is within the permissible ± 10% at the power terminal. 2. Working environment. Focus on checking whether the temperature, humidity, vibration, dust, interference, etc. meet the standard working environment. 3. Power supply for input and output. Available in the corresponding ...

Omron's first smart ventilator was officially launched on JD Health Omron's first smart ventilator was officially launched on JD Health

On November 2, 2022, Omron's first intelligent ventilator, the fully automatic single-level ventilator HPS-A500, was officially launched at JD Health. The product integrates a number of patents and has a number of humanized functions, which will accelerate Omron's layout in the field of respiratory disease management. Omron ...

Omron PLC's equipment disassembly sequence and method Omron PLC's equipment disassembly sequence and method

(1) Shutdown for maintenance, more than two people must supervise the operation; (2) Change the mode selector switch on the front panel of the CPU from "Run" to "Stop" position; (3) Turn off the main power supply of PLC power supply, and then turn off other power supplies to the mold saka; (4) ...

There are four main characteristics of Omron PLC There are four main characteristics of Omron PLC

1. High reliability The PLC replaces a large number of intermediate relays and time relays in the relay control system with software, and the wiring can be reduced to less than one-tenth of the relay control system, which greatly reduces the possibility of poor contact contact. In addition, the PLC itself has a strong self-diagnosis ...

Omron PLC troubleshooting Omron PLC troubleshooting

1. Power check: The first thing to analyze is the reliability of the power supply and ground of the Omron PLC. Visually inspect power and ground cables for damaged, corroded, or other suspicious links. Power supplies can also be electrically tested. If there is AC power in the PLC processor, test ...

Analysis of the location and cause of Omron PLC failure Analysis of the location and cause of Omron PLC failure

1. External equipment failure. Such faults come from external devices such as various sensors, switches, actuators, and loads. The failure of this part of the equipment will directly affect the control function of the system. This type of failure is usually caused by the quality and longevity of the equipment itself. 2. System failure ...

What are the common faults of Omron relays? What are the common faults of Omron relays?

Fault 1: Do not exceed the rated voltage of the load current during the use of the OMRON relay, because when the applied rated voltage is too large, it may cause a local short circuit between the cores of the OMRON relay coil and poor operation of the AC operation relay. And there are ...

Routine maintenance methods of Omron relays Routine maintenance methods of Omron relays

1. In the operation of Omron relay, if there is an abnormal sound or other abnormal conditions, the operation should be terminated first, and the skilled and professional repair staff should be notified to repair, and the operation can be resumed after the common fault is cleared. 2. In the whole process of maintenance, check the spring ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top