1. The low-voltage fuse cannot be used as an overload maintenance of the motor.
2. The additional voltage of the fuse must be greater than or equal to the operating voltage of the distribution line.
3. The additional current of the fuse must be greater than or equal to the additional current of the melt.
4. The breaking capacity of the fuse must be greater than the largest short-circuit current that the distribution line may present.
5. The selection of the additional current of the melt is necessary to meet the normal operating current of the line and the starting current of the motor.
6. For short-circuit maintenance of electric furnace and lighting loads, the extra current of the melt is equal to or slightly greater than the additional current of the load.
7. For a single motor, the extra current of the melt ≥ the additional current of the (1.5-2.5) motor.
8. In the power distribution system, the upper and lower levels should cooperate harmoniously to complete the purpose of selective maintenance. The next level should be smaller than the previous level.
9. The porcelain plug-in fuse should be installed straight, and it is necessary to use a qualified fuse, and the fuse shall not be replaced by other copper wires.
10. The power inlet of the spiral fuse should be connected to the center terminal of the base, and the outgoing wire of the load should be connected to the terminal of the threaded shell.
|
More on that
|
Inverter circuit structure - LS generates electricity
The main circuit is the power replacement part of the power supply for the asynchronous motor, and the main circuit of the inverter can be roughly divided into two categories: the voltage type is to change the DC of the voltage source to the communication of the DC port of the inverter, and the filter is the capacitor. The current type is to change the DC of the current source to the communication ...
|
|
The principle and function of the power production contactor
The working principle of the power production contact is: when the contact coil is energized, the coil current generates a magnetic field, and the generated magnetic field leads the static iron core to produce electromagnetic attraction to the iron core, and drives the AC contact action, the normally closed contact is disconnected, the normally open contact is closed, and the two are connected to each other. When the coil is de-energized, the electric ...
|
|
Relationship between motion control and frequency converter
Motion control has a significant period characteristic, it is a combination of a variety of high-tech to push industrial automation, office automation and home automation to a higher stage. At present, the motion control is mainly composed of three parts: inverter, motor and controller.
...
|
|
LS Group witnesses the reopening of the "Viet Nam Professional Football League".
The Viet Nam Professional Football League, sponsored by LS Group, began operations in June and is hosted by Viet Nam Professional Football Joint Stock Company. With the comeback of football events such as the Korea K League and the Bundesliga, more and more football events are also brewing to restart.
...
|
|
Interference phenomenon of LS power inverter
1. As soon as the inverter of the heat exchange station is opened, the pressure transmitter jumps randomly;
2. In the water supply controlled by the inverter, the pressure transformer is used as a signal to collect the pressure, and the pressure transformer is disturbed by the inverter;
3. When the inverter starts the motor, the voltage converter signal is unstable and beats violently;
4. Pressure transformer (4-20 ...
|
|
LS produces common sense of electroplastic case circuit breaker
(1) Tripping
LS electric molded case circuit breaker basically involves the tripping unit in the process of practical application, and the tripping is generally a tripping method of thermomagnetic tripping or electronic tripping.
In the process of practical application, if it is a ...
|
|
The cause of motor burnout caused by the inverter - electricity production
In fact, the fault of the motor is not the cause of the motor itself, most of them are caused by the non-standard debugging of the inverter or the wrong inverter motor when the inverter motor is used, etc., mainly in the following situations:
1. Treat the general motor as a ...
|
|
Distinguish between good and bad inverters - LS produces electricity
The quality of a thing is relatively speaking, the inverter as a power supply used to drive the motor to run, its function is to regulate the speed, under the premise of normal wiring, reasonable parameters, and no fault with the load, if the speed of the motor can be controlled according to the requirements, the shaking error is less than the equipment ...
|
|
LS Electric reached a strategic cooperation with Nandu Power Supply and Changzhou Kunlan
Due to the "new infrastructure" policy, the Chinese government has vigorously promoted the new energy and ESS markets, and according to CNESA, the cumulative electrochemical energy storage scale in China will reach 19.3GW in 2023, which is expected to exceed 20% of the global market.
June 3 ...
|
|
Explanation of basic terms of electrician - electricity production
1. Active power - in the process of generating and transmitting alternating current energy, the part of energy used to convert into electromagnetic methods is called active power
2. Reactive power - in the process of AC electric energy generation and transmission, it is used for electromagnetic field AC in the circuit.
|
|
LS power generation low-voltage universal inverter vector control mode
The method of vector control frequency conversion speed regulation is to change the stator current Ia, Ib, Ic of the asynchronous motor in the three-phase coordinate system, after the three-phase - two-phase change, equivalent to the communication current Ia1Ib1 under the two-phase static coordinate system, and then after the directional rotation according to the rotor magnetic field, it is equivalent to synchronous rotation sitting.
|
|
Why can't the inverter be equipped with a leakage protector - power generation
When using an inverter, a leakage maintainer must not be used. This is a major principle of the use of frequency converters.
Some users choose the corresponding leakage maintainer for the inverter when using the inverter. *The result is: the inverter moves together ...
|
|
LS power production contactor selection
How LS Contactor Works:
Generally, after the contactor coil is energized, the entire coil current will generate a magnetic field, which will make the core inside have electromagnetic attraction to attract the core, and let their communication contactor point action normally closed contact disconnect, or close, which ...
|
|
Introduction of LS power inverter governor
Frequency conversion governor is the power frequency power supply (50Hz or 60Hz) into various frequencies of communication power supply, in order to complete the variable speed operation of the motor equipment, during which the control circuit completes the control of the main circuit, the rectifier circuit converts the communication power into direct current, and the output input of the DC center circuit to the rectifier circuit ...
|
|
Inverter installation environment requirements - LS power generation
Inverter device environmental requirements 1: operating temperature;
The inverter is a high-power electronic component, which is easily affected by the working temperature, and the product is generally required to be 0-55 °C, but in order to ensure that the work is [safe] [complete] [can be] [reliable], the use should be considered to leave room for control, and the control is at 40 ...
|
|
Manufacturing Automation Terminology – LS Electricity Generation
I/O Points:
When discussing control systems, I/O points are a term that is often heard. It refers to the input/output point, I stands for INPUT, which refers to the input, and O stands for OUTPUT, which refers to the output. The inputs/outputs are for the control system, and the input refers to the ...
|
|
Precautions for the coordination of inverter and PLC - LS produces electricity
As an alternative to traditional relays, PLC is widely used in various fields of industrial control. Because the PLC can be used to change the control process with software, and has the characteristics of small size, sensitive assembly, simple programming, strong anti-disturbance ability and high reliability, it is especially suitable for operation in harsh environments. ...
|
|
The main functions and functions of LS power production PLC
1. For sequential control: sequential control is based on the current and pre-historical conditions of the input switch, and produces the required switching output, so that the system can work in a certain order. This is the basic manipulation of the system. It is also a common manipulation in discrete production processes.
...
|
|
The inverter generates electricity through the principle of intermediate DC bus power supply - LS
Most of the inverter manufacturers produce traditional inverters, and their control systems and other power supplies are directly provided by single-phase or three-phase power grids. However, due to the increasing use of VFDs and servo motor amplifiers, a new power supply may emerge: powered by the central DC bus of the VFD. This electric ...
|
|
Analysis of common faults of LS AC contactors
AC contactor is generally used to turn on or off the power supply in the control circuit of electromechanical equipment, it can frequently turn on or off the AC circuit, and can realize long-distance control.
The toucher is mainly composed of a contact system and an electromagnetic system, and the problem of AC contactor is generally generated in the coil.
|
|