The characteristics of Hollysys LK series PLC are introduced in detail

Create Date: 2024-8-30 12:03:23|Source: HollySys/HollySys

LK is a programmable controller (PLC) product launched by Hollysys for medium and high-performance control fields. Fully integrating the advantages of DCS and PLC, using high-performance analog processing technology, miniaturized structural design, open industry standards, and general system platform, the product not only has powerful functions, but also has higher reliability, better openness and ease of use, and the product has passed CE and UL certification.

LK is widely used in rail transit, energy, water treatment, water conservancy and hydropower, heating, building materials, electric power, textile, papermaking, printing, pharmaceutical, chemical, metallurgy, intelligent building and other fields.
The characteristics of Hollysys LK series PLC are introduced in detail
  Features:

Performance

It is equipped with an industrial-grade (533MHz) processor with nanosecond (13ns) processing speed

Up to 57,344 digital I/O and 3,584 analog I/O

The program size can be up to 16MB, the data capacity can be up to 64MB, and the power-down hold area can be up to 1MB

High reliability

Power supply redundancy, CPU redundancy, Ethernet redundancy, PROFIBUS-DP bus redundancy are supported

It has the function of presetting the output in the event of a communication failure

Provide three proof (moisture-proof, anti-salt spray, anti-mildew) module

Multi-machine interconnection to achieve data sharing

Data sharing between up to 32 stations is possible via its own integrated Ethernet interface

The size of the shared data can be configured to share up to 700 words at a time

Ideal for metro and highway tunnel monitoring applications

Ease of use

The module is miniaturized and intelligently designed, with self-diagnosis function

Flexible SD memory card for engineering recovery, backup, encryption

It is IEC61131-3 compliant and supports LD, IL, FBD, ST, SFC, and CFC programming languages

Ease of maintenance

It supports live plugging and unplugging, and can replace faulty modules without stopping the machine

The terminal blocks are designed to be independent of the I/O module and the terminals are pluggable

The backplane is designed with anti-mixing pins to avoid inserting the wrong module

Openness and extensibility

Integrated Ethernet, PROFIBUS-DP, RS232, RS485 interfaces

It supports multiple communication protocols such as TCP/IP, MODBUS, PROFIBUS-DP, OPC, and free port

Remote I/O can be extended up to 20 km

Hardware architecture

The LK hardware system is composed of CPU module, I/O module, communication module, special function module and backplane, which can be flexibly combined according to different applications and different needs to meet the wide range of applications of automatic control.

CPU module

The heart of the entire system, which is used to execute user programs, process local I/O and process data, and distribute I/O via fieldbus control

A variety of CPU modules are available for users to choose from, with built-in PROFIBUSDP interface, Ethernet interface, RS232 and RS485 interface

LED indicators, key switches, station address DIPs, SD memory card slots, and spare battery slots are available

I/O modules

It is used for the processing of DI/DO and AI/AO signals, including DI, transistor DO, voltage/current/thermocouple/RTD AI, voltage/current AO, etc

A wide range of I/O modules are available to meet the needs of different applications, from discrete control to process control

Communication interface module

Used for system expansion and communication with third-party devices

It supports TCP/IP, PROFIBUS-DP, MODBUS, OPC, free port and other protocols

Special function modules

Designed for tasks such as high-speed counting

Backplate

It is used to install all modules and provide data communication connections between the CPU and other modules

It includes a local backplane, which is used to install CPU modules, I/O modules, communication interface modules, and special function modules, and an expansion backplane is used to install communication interface modules and I/O modules

Redundant systems

For some control occasions with high reliability requirements, PLC failure will cause large economic losses or social impacts. For this purpose, LK offers users a solution for redundant systems that support power supply redundancy, CPU redundancy, Ethernet redundancy and PROFIBUS-DP bus redundancy.

The LK redundancy system consists of a CPU module that supports redundancy functions, a PROFIBUS-DP communication interface module, a local backplane with dual CPU sockets, an expansion backplane, and an I/O module.

Redundancy

Data is synchronized between the two CPUs via a high-speed backplane bus, eliminating the need for a dedicated synchronization module

The PLC hardware configuration and program writing are the same as those of the stand-alone system, and the system automatically backs up to the slave after the project is downloaded to the master

Disturbance switching, the switching time is < 50ms, and there is no alarm or loss of interruption in the switching process

Economical single-rack hardware

Redundant design

The CPU module that supports redundancy is mounted on a local backplane with dual CPU sockets

After powering on, the redundant CPU module is automatically set to execute user programs synchronously in master, slave mode, and slave, and the host controls the output

When the master fails, the slave automatically switches to the master to ensure the normal operation of the system

Ethernet redundancy

There is a redundant Ethernet interface integrated in the CPU module, which is led out of the backplane, adopts a standard RJ45 interface, conforms to the IEEE802.3/u standard, the communication rate is 10M/100Mbps self-adaptive, and the transmission medium is twisted pair

Bus redundancy

A redundant PROFIBUS-DP bus interface is integrated in the CPU module, which is a communication interface for data exchange between the CPU module and the I/O module from the backplane, realizing bidirectional data transmission between the master and the slave

Redundant PROFIBUS-DP fieldbus in accordance with IEC61158 international standards and EN50170 European standards, with a communication rate of 9.6Kbps - 1.5Mbps optional

Power redundancy

The LK910 power supply can be operated in parallel with two or more redundant configurations, which can realize the non-disturbance switching of power supply to reduce the failure caused by the power supply

More on that
Hollysys successfully signed a contract with Luxi Chemical for a 1.2 million tons/year bisphenol A plant project Hollysys successfully signed a contract with Luxi Chemical for a 1.2 million tons/year bisphenol A plant project

Recently, Hollysys successfully signed a contract with Luxi Chemical Group Co., Ltd. (hereinafter referred to as Luxi Chemical) for a 1.2 million tons/year bisphenol A equipment project. The project is a key project in Shandong Province in 2021, which will not only greatly improve the competitiveness of Luxi Chemical polycarbonate in the industry, but also have a significant impact on China's phenol ...

Hollysys released a new DCS control system Hollysys released a new DCS control system

Hollysys' safe and trustworthy DCS control system uses the controller K-CU11 for the K series large-capacity trusted controller module, which adopts advanced PowerPC architecture high-performance main processor and security components based on national cryptography algorithm, and has the security functions of static trusted start and dynamic trusted measurement. ...

Hollysys PLC - How to maintain the PLC control cabinet? Hollysys PLC - How to maintain the PLC control cabinet?

1. Data backup When carrying out maintenance, we must cut off the power, data backup between power outages is an important link, for the data that needs to be archived for a long time, you can back up the historical trend data to the mobile hard disk, and then turn off the Windows-based operating system (Note...

Hollysys DCS - Introduction to I/O in DCS control system Hollysys DCS - Introduction to I/O in DCS control system

The control system needs to establish the input and output channels of the signals, which is called I/O. The I/O in a DCS is generally modular, with one or more I/O channels on one I/O module for connecting sensors and actuators (control valves). The control unit of the DCS: a process control station is ...

What are the functions of Hollysys PLC - PLC data acquisition gateway? What are the functions of Hollysys PLC - PLC data acquisition gateway?

1. Rich networking and interface functions, easy to deploy It supports 5G/4G/3G/WIFI/Ethernet, WAN/optical fiber and other network access modes, network port/serial port/IO port/CAN port and other equipment access, and supports LoRa wireless transmission, disconnection reconnection and multi-network mutual backup function. 2. Abundant ...

Hollysys debuted at the XCon2022 Security Focus Information Security Technology Summit Hollysys debuted at the XCon2022 Security Focus Information Security Technology Summit

On September 19, 2022, the XCon2022 Security Focus Information Security Technology Summit was successfully held in Beijing. More than 10 technical experts, heads of security departments, and front-line security experts from well-known domestic network security enterprises shared in-depth topics at the meeting.

Hollysys signed a strategic cooperation agreement with Jinan Iron and Steel International in Jinan Hollysys signed a strategic cooperation agreement with Jinan Iron and Steel International in Jinan

Hangzhou Hollysys Automation Co., Ltd. (hereinafter referred to as Hanghe) and Jinan Iron and Steel Group International Engineering Technology Co., Ltd. (hereinafter referred to as Jinan Iron and Steel International) signed a strategic cooperation agreement in Jinan. Luan Yuandi, Deputy General Manager of Jinan Iron and Steel International, Sun Jiaying, Director of the Automation Division, and Liu Xinjie, Director of the Automation Office...

Hollysys PLC - PLC is classified by function Hollysys PLC - PLC is classified by function

According to the different functions of PLC, PLC can be divided into three categories: low-grade, mid-range and high-end. (1) Low-grade PLC Low-grade PLC has basic functions such as logic operation, timing, counting, shifting, self-diagnosis, monitoring, etc., and can also have a small amount of analog input/output, arithmetic operation, math...

Hollyps PLC - the control method of PLC and frequency converter connection Hollyps PLC - the control method of PLC and frequency converter connection

1. Use the analog output module of the PLC to control the analog output module of the inverter The analog output module of the PLC outputs a 0-5V voltage signal or a 4-20mA current signal, which is used as the analog input signal of the inverter to control the output frequency of the inverter. This control method is simple to wiring, but it needs to be selected and changed.

Hollysys DCS - Introduction to the hardware architecture of DCS Hollysys DCS - Introduction to the hardware architecture of DCS

Examining the hierarchical structure of DCS, DCS level and control management level are the two most basic links that make up DCS. The process control stage specifically realizes the decentralized control functions such as signal input, conversion, operation and output. The controls at the process control level vary in different DCS, ...

Hollysys PLC - what are the application fields of PLC Hollysys PLC - what are the application fields of PLC

1. Logic control of switching quantity This is the most basic and most extensive application field of PLC, which replaces the traditional relay circuit to achieve logic control and sequence control, which can be used for the control of a single device, as well as for multi-machine group control and automatic assembly line. Such as injection molding machines, printing machines, ...

Hollysys PLC - Classification and application of PLC Hollysys PLC - Classification and application of PLC

1. Switch logic control Switching logic control is the basis of PLC. It is the first use case and the most extensive of all. Replace the previous relay circuit control and realize logic sequence control; It can be used for the control of stand-alone equipment, and can also be used for group control and ...

Hollysys DCS - What are the specific contents of the major and minor repair projects of the DCS system? Hollysys DCS - What are the specific contents of the major and minor repair projects of the DCS system?

(1) Overhaul projects DCS system overhaul is carried out in the random group of main equipment overhaul, and the overhaul project includes the following: 1) Conduct a comprehensive inspection of the control equipment and make a record. 2) Copy the configuration of all modules, and verify the marks and addresses of the modules. 3) Qing ...

Hollysys PLC - what are the anti-interference countermeasures of PLC and touch screen? Hollysys PLC - what are the anti-interference countermeasures of PLC and touch screen?

In order to improve the anti-interference ability of the PLC system, we should start from the design. In the anti-interference design of specific projects, products with strong anti-interference ability can be selected to improve the anti-interference of equipment and systems by suppressing interference sources, cutting off or attenuating the transmission path of electromagnetic interference, and using software means.

Hollysys DCS——What should I pay attention to when cleaning the DCS system? Hollysys DCS——What should I pay attention to when cleaning the DCS system?

1. Power off 2. Cleaning the ash can not only clean the surface, but also clean the internal card key of the controller 3. If there is a supporting UPS, open the UPS and clean the ashes 4. After cleaning the ash, check whether the card and relay are loose, and tighten them if they are loose 5. The relays with frequent actions should be cleaned regularly.

Hollysys won the 2022 China Intelligent Transportation Association Science and Technology Award" Hollysys won the 2022 China Intelligent Transportation Association Science and Technology Award"

On October 18, 2022, the China Intelligent Transportation Association released the list of winners of the "2022 China Intelligent Transportation Association Science and Technology Award", which includes the Science and Technology Progress Award, the Technology Invention Award, and the Outstanding Innovative Talent Award. Among them, Beijing Hollysys System Engineering Co., Ltd. ...

Hollysys PLC - the importance of PLC industrial gateway Hollysys PLC - the importance of PLC industrial gateway

1. Realize remote control of industrial field equipment; 2. The PLC industrial gateway realizes remote upgrade of equipment firmware, downloads the program, and can flexibly access various equipment management platforms; 3. Realize remote control of industrial site touch screen and remote mapping of configuration screens; 4. PLC industry ...

and Lisi DCS - the difference between DCS control and PLC control and Lisi DCS - the difference between DCS control and PLC control

1. PLC programmable logic controller (programmable controller). 2. DCS system pays more attention to the field of process control. Such as chemical, smelting, pharmaceutical, etc. It mainly monitors and controls some field parameters, while PLC focuses on logic control. machining). Of course, the PLC's ...

What are the characteristics of Hollysys PLC - PLC program? What are the characteristics of Hollysys PLC - PLC program?

1. Correctness (low debugging cost) First of all, the PLC program must be able to work correctly to meet the requirements of the actual control process. This is the essence of the PLC program, and if you don't do that, nothing else makes sense. 2. Reliability (low maintenance cost) Not only to ...

Hollysys DCS - DCS daily maintenance and fault analysis and troubleshooting methods Hollysys DCS - DCS daily maintenance and fault analysis and troubleshooting methods

01. Power supply The DCS power supply system is mostly a "dual backup hot redundant power supply", and the prevention and control of power failures is mainly reflected in the inspection and daily maintenance. Generally speaking, as long as the unit is normal ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top