Hollysys PLC - PLC is classified by function

Create Date: 2024-8-30 12:03:23|Source: HollySys/HollySys

According to the different functions of PLC, PLC can be divided into three categories: low-grade, mid-range and high-end.

(1) Low-grade PLC

Low-grade PLC has basic functions such as logic operation, timing, counting, shifting, self-diagnosis, monitoring, etc., and can also have a small number of analog input/output, arithmetic operation, data transmission and comparison and communication functions, mainly used for logic control, sequence control or a small amount of analog control system stand-alone control system.

(2) Mid-range PLC

In addition to the functions of low-grade PLC, the mid-range PLC also has strong functions such as analog input/output, arithmetic operation, data transmission and comparison, number system conversion, remote I/O, subroutine and communication networking. Some of them can also be equipped with interrupt control, PID control and other functions, which are suitable for complex control systems.

(3) High-grade PLC

In addition to the functions of mid-range PLC, high-end PLC also adds the operation of symbolic arithmetic operation, matrix operation, bit logic operation, square root operation and other special functional functions, tabulation and table transmission functions.

High-grade PLC has stronger communication networking function, which can be used for large-scale process control or to form a distributed network control system to realize factory automation.
Hollysys PLC - PLC is classified by function


More on that
Hollysys PLC – How to calculate the analog quantity in PLC Hollysys PLC – How to calculate the analog quantity in PLC

1、-10—10V。 When the voltage of -10V-10V is converted to F448-0BB8Hex (-3000-3000) at 6000 resolution; At 12000 resolution, it is converted to E890—1770Hex (-6000—6000). 2、0—10V。 At a voltage of 0-10V, at a resolution of 12000 ...

Century Qualcomm and Hollysys reached a strategic cooperation Century Qualcomm and Hollysys reached a strategic cooperation

With the inclusion of "exploring the construction of digital twin cities" in the 14th Five-Year Plan, the field of intelligent transportation is being endowed with more new business value. Recently, Century Qualcomm and Hollysys reached a strategic cooperation, based on the principle of "giving full play to advantages, mutual promotion, long-term cooperation, mutual benefit and win-win", ...

Hollysys was once again certified by the China Software Industry Association Hollysys was once again certified by the China Software Industry Association

Recently, identified by the Beijing Software and Information Service Industry Association, after a strict audit and evaluation process, in accordance with the relevant provisions of the national "Software Enterprise Evaluation Standards" and "Software Product Evaluation Standards", the China Software Industry Association announced the latest batch of "software enterprises" list, Beijing Heli ...

Hollysys PLC - three forms of PLC output circuit Hollysys PLC - three forms of PLC output circuit

1. Relay output circuit This type of output circuit form can be either DC or AC. The output circuit form of PLC relay allows the load to be generally below AC250V/50V, the load current can reach 2A, and the capacity can reach 80-100VA (voltage × current), so ...

Hollysys attended the 2021 China Software Industry Annual Conference Hollysys attended the 2021 China Software Industry Annual Conference

On April 7, 2021, the "2021 China Software Industry Annual Conference" hosted by the China Software Industry Association was held in Beijing. With years of technology accumulation and outstanding strength, Hollysys Group won the title of "The Most Influential Enterprise in China's Software Industry in 2020", as well as the "...

Hollysys DCS - Introduction to I/O in DCS control system Hollysys DCS - Introduction to I/O in DCS control system

The control system needs to establish the input and output channels of the signals, which is called I/O. The I/O in a DCS is generally modular, with one or more I/O channels on one I/O module for connecting sensors and actuators (control valves). The control unit of the DCS: a process control station is ...

Hollysys will make a blockbuster appearance at the first Shenzhen Nuclear Expo in 2022 Hollysys will make a blockbuster appearance at the first Shenzhen Nuclear Expo in 2022

From November 15th to 17th, the 2022 China Nuclear Energy High-Quality Development Conference and Shenzhen International Nuclear Energy Industry Innovation Expo (hereinafter referred to as the "2022 Shenzhen Nuclear Expo") will be grandly reopened at the Shenzhen World Convention and Exhibition Center.   The theme of this year's Nuclear Expo is "Nuclear Gathering in the Bay Area, Activating the World".

Hollysys signed a contract with Lysys for the integrated management platform project of smart tunnel of Linzhou-Changzhi Expressway in Henan Hollysys signed a contract with Lysys for the integrated management platform project of smart tunnel of Linzhou-Changzhi Expressway in Henan

Recently, Hollysys signed a contract for the comprehensive management platform project of smart tunnel of Linzhou-Changzhi Expressway in Henan Province. Linzhou to Changzhi Expressway is a traffic artery that crosses the Grand Canyon of Taihang Mountain, through Henan and Shanxi, with a total of 7 pairs (14) tunnels.

Hollysys HOLLiAS MACS IC helps the localization of large-scale thermal power units Hollysys HOLLiAS MACS IC helps the localization of large-scale thermal power units

At 15:05 on January 12, 2022, Datang Anhui Luoneng Power Generation Co., Ltd. (hereinafter referred to as Datang Luohe) successfully completed the full-load trial operation of Unit 5 after comprehensive upgrading, marking the smooth operation of Unit 5 of Datang Luohe Power Plant after the transformation. Hollysys HOLLiAS MACS IC completely ...

Hollysys released a new 100% localized system Hollysys released a new 100% localized system

On the morning of October 20, 2021, at the Epec Industrial Products Exhibition, Hollysys released a new 100% localized system - 'HOLLiAS MACS IC fully autonomous and controllable DCS system'. The system integrates the controller microkernel architecture independently developed by Lisi, embedded ...

Hollysys DCS output module - K-AO02 advantages introduced Hollysys DCS output module - K-AO02 advantages introduced

1. The output accuracy is as high as 0.05%, which greatly improves the operation efficiency of the system. 2. The full-scale output of the channel signal is 0-22.7mA, and the output range is wide; 3. It can be adapted to the enhanced base to achieve channel resistance to 220VAC; 4. It has a perfect channel signal diagnosis function, which can be realized.

Hollysys PLC - PLC should be noted in operation (2) Hollysys PLC - PLC should be noted in operation (2)

2. Interference in the control system and its sources On-site electromagnetic interference is one of the most common factors in PLC control system and most likely to affect the reliability of the system. It is therefore essential to know the source of on-site disturbances ...

Troubleshooting steps of Hollysys DCS system Troubleshooting steps of Hollysys DCS system

The steps of DCS system troubleshooting include: (1) Check the fault caused by improper use. Common types of operational faults include operator errors, terminal wiring faults, module installation faults, and power supply failures. (2) Troubleshoot the improper operation of the DCS system ...

Common fault parts and maintenance of Hollysys PLC Common fault parts and maintenance of Hollysys PLC

1. Lack of motivation It may sound simple, but it's good to check the simple stuff first. Thoroughly inspect all power connections and cables for damage that could cause a short circuit. Make sure your power supply is functioning properly. Use a voltmeter to check if the grounding and voltage are correct. 2. Bad ...

Hollysys DCS - the selection, design and debugging of DCS system Hollysys DCS - the selection, design and debugging of DCS system

1. The configuration of the system and controller should focus on reliability and load rate (including redundancy). The communication load rate must be controlled within a reasonable range, and the load rate of the controller must be balanced as much as possible to avoid the occurrence of "high load" problems. 2. The distribution of system control logic should not be too much.

Hollysys PLC - What are the applications of PLC in CNC machine tools? Hollysys PLC - What are the applications of PLC in CNC machine tools?

1. The application form of PLC in CNC machine tools PLC is used in CNC machine tools, and there are usually two forms: one is called built-in: the other is called free-standing. Built-in PLC is also known as integrated PLC, the CNC system in this way, at the beginning of the design of the NC and PLC combined ...

and Nesbitt DCS - the difference between SCADA and DCS and PLC and Nesbitt DCS - the difference between SCADA and DCS and PLC

To put it simply, DCS is mainly used for process automation, PLC is mainly used for factory automation (production lines), and SCADA is mainly for wide-area needs, such as oil fields and pipelines that stretch for thousands of miles. If from the point of view of computers and networks, they are unified, and the reason for the difference is mainly in ...

Hollysys successfully signed the first 100 billion cubic meter gas field project in Bohai Bay to help achieve the "double carbon" goal Hollysys successfully signed the first 100 billion cubic meter gas field project in Bohai Bay to help achieve the "double carbon" goal

Recently, Hangzhou Hollysys Automation Co., Ltd. successfully signed the first 100 billion cubic meters of gas field project in Bohai Bay (1) - CNOOC Tianjin Branch Bozhong 19-6 condensate gas field phase I development project (hereinafter referred to as: Bozhong 19-6 project), and will provide PCS (DCS), ESD, FGS, ...

Hollysys PLC - PLC serial communication knowledge Hollysys PLC - PLC serial communication knowledge

1. What is serial communication? Serial is a very versatile protocol for device communication on a computer (not to be confused with Universal Serial Bus or USB). Most computers contain two serial ports based on RS232. The serial port is also an instrument ...

Hollysys PLC - the debugging steps of PLC Hollysys PLC - the debugging steps of PLC

1. Check the circuit according to the drawing (without power transmission) The drawings of the general PLC system include two parts: the drawings in the cabinet and the drawings outside the cabinet; The drawing in the cabinet refers to the wiring diagram inside the cabinet; The out-of-cabinet drawings are the wiring diagrams of all electrical cabinets that are connected out. This part needs to be checked for; 1. Drawings ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top