Hollysys released a new DCS control system

Create Date: 2024-8-30 12:03:23|Source: HollySys/HollySys

Hollysys' safe and trustworthy DCS control system uses the controller K-CU11 for the K series large-capacity trusted controller module, which adopts advanced PowerPC architecture high-performance main processor and security components based on national cryptography algorithm, and has the security functions of static trusted start and dynamic trusted measurement.
Hollysys released a new DCS control system
  The industrial control system represented by DCS is the key equipment to realize the digitalization, networking and intelligence of the manufacturing industry. The core control equipment and system is the command brain, control center and security center of major projects in the fields of modern electric power, petrochemical, metallurgy, national defense, etc., and is also an important foundation for national economy, social operation and national security. With the emergence of new technologies such as industrial Internet and cloud computing, industrial control systems have gradually evolved from closed and isolated systems to open interactive systems, which has brought new challenges to information security.

Traditional control system defense mainly uses firewalls, patches and other means to strengthen security on the basis of blocking, isolation and vulnerability analysis. However, this passive defense method has been difficult to resist the rapid development of cyber attack technologies and segments, and various new and unknown threats have exacerbated this phenomenon. Once the intrusion attack breaks through the traditional passive defense, it will seriously threaten the safe operation of the industrial control system and even cause serious accidents. In this context, Hollysys took the lead in releasing a new generation of secure and trustworthy DCS control system, which has endogenous security protection capabilities compared with traditional control systems.

Key innovations

The secure and trusted DCS control system is designed based on the trusted computing technology system, and is equipped with a secure and trusted control system with active immunity capability for life cycle network security, with embedded trusted computing endogenous security technology architecture and static trustworthiness

Key core technology innovations such as start-up, life-cycle trusted protection system, firmware trusted upgrade technology, and national secret secure communication.

In the start-up stage of the secure and trustworthy DCS control system, a trusted chain transmission model is constructed to ensure trusted start-up, and a dynamic measurement model is established during operation to ensure the safe and trustworthy operating environment of the control system and realize trusted protection throughout the life cycle.

The secure and trustworthy DCS control system has the static trusted start function, the active defense function based on the dynamic measurement of the quadruple, and the firmware trusted upgrade function.

Defenses

Whether the bootloader, operating system, application code and data loaded by boot loading have been tampered with, and are protected by the static trusted boot function;

In the operation stage, the control system is maliciously attacked and causes abnormal operation, and the dynamic trust measurement function is used to defend it.

In the upgrade stage, the correctness of the firmware source file, the interception of malicious upgrade behaviors, and the encryption of the communication process are all guaranteed by the firmware trusted upgrade function.

More on that
The difference between Lysys plc - RS232 interface and RS485 interface The difference between Lysys plc - RS232 interface and RS485 interface

1. The physical structure of the interface 1. RS232 interface: One of the computer communication interfaces, usually RS-232 interface in 9 pin (DB-9) or 25 pin (DB-25) form, generally there will be two sets of RS-232 interfaces on personal computers, respectively called COM ...

Hollysys DCS - the connection method between thermocouple and DCS Hollysys DCS - the connection method between thermocouple and DCS

1. The thermocouple uses a compensation wire, and there can be a node in the middle, but the corresponding compensation cable must be used to directly connect to the DCS thermocouple module, such as the LLMUX card in HONEYWELLTPS. Minimize nodes to reduce interference. In addition, in the DCS configuration, it is necessary to select the corresponding thermocouple model, and supplement the ...

Hollysys DCS control system configuration process Hollysys DCS control system configuration process

1. Preliminary preparations Engineering configuration is operated at the engineer station, and before engineering configuration, it is necessary to have the necessary tools and information, specifically: Tools: refers to the hardware environment and software environment used in engineering configuration, usually refers to the ...

Hollysys PLC - Introduction to the classification of PLC according to the structure and form Hollysys PLC - Introduction to the classification of PLC according to the structure and form

According to the structural form of PLC, PLC can be divided into two categories: integral type and modular type. (1) Integral PLC The integral PLC is a centralized power, CPU, I/O interface and other components in a chassis, which has the characteristics of compact structure, small size and low price. Small PLC ...

Hollysys DCS - Introduction to the main features of DCS Hollysys DCS - Introduction to the main features of DCS

(1) High reliability DCS is designed to be fault-tolerant, so that when a computer fails, it does not cause the system to lose other functions. In addition, because the tasks undertaken by the individual computers in the system are relatively simple, it is possible to adopt a specific structure and ...

Common fault parts and maintenance of Hollysys PLC Common fault parts and maintenance of Hollysys PLC

1. Lack of motivation It may sound simple, but it's good to check the simple stuff first. Thoroughly inspect all power connections and cables for damage that could cause a short circuit. Make sure your power supply is functioning properly. Use a voltmeter to check if the grounding and voltage are correct. 2. Bad ...

Hollysys DCS - DCS fault maintenance measures Hollysys DCS - DCS fault maintenance measures

Whether it is a new unit or an upgraded DCS, the equipment of the system and controller should focus on the reliability and load factor (including redundancy) objectives. The load rate planning of the communication bus must be controlled within a reasonable range, and the load rate of the controller should be balanced as much as possible.

Hollysys DCS output module - K-AO02 advantages introduced Hollysys DCS output module - K-AO02 advantages introduced

1. The output accuracy is as high as 0.05%, which greatly improves the operation efficiency of the system. 2. The full-scale output of the channel signal is 0-22.7mA, and the output range is wide; 3. It can be adapted to the enhanced base to achieve channel resistance to 220VAC; 4. It has a perfect channel signal diagnosis function, which can be realized.

Hollysys PLC - Introduction to the working principle and operation mode of PLC controller Hollysys PLC - Introduction to the working principle and operation mode of PLC controller

How a PLC controller works 1. Scanning technology When the PLC is put into operation, its working process is generally divided into three stages, namely input sampling, user program execution and output refresh. The completion of these three phases is called a scan cycle. During the entire operation ...

Hollysys PLC - What are the three large quantities in PLC? Hollysys PLC - What are the three large quantities in PLC?

1. The switching quantity is also called the logical quantity, which means that there are only two values, 0 or 1, ON or OFF. It is the most commonly used control, and controlling it is the advantage of PLC, and it is also the most basic application of PLC. The purpose of switching control is to follow the current input combination with the historical input according to the switching quantity.

Hollysys PLC - the characteristics of the working process of PLC Hollysys PLC - the characteristics of the working process of PLC

(1) The PLC adopts the working mode of centralized sampling and centralized output, which reduces the influence of external interference. (2) The working process of PLC is the process of cyclic scanning, and the length of cyclic scanning time depends on the speed of instruction execution, the length of the user program and other factors. (3) Output ...

Hollysys successfully signed 16 sets of control system projects for 10 million tons of oil refining enterprises Hollysys successfully signed 16 sets of control system projects for 10 million tons of oil refining enterprises

Recently, Hangzhou Hollysys Automation Co., Ltd. (hereinafter referred to as Hollysys Company) successfully signed a contract with PetroChina Liaoyang Petrochemical Branch (hereinafter referred to as PetroChina Liaoyang Petrochemical) to construct and rectify 16 sets of control system projects during the planned overhaul in 2023 - 9 ...

Hollysys PLC - the importance of PLC industrial gateway Hollysys PLC - the importance of PLC industrial gateway

1. Realize remote control of industrial field equipment; 2. The PLC industrial gateway realizes remote upgrade of equipment firmware, downloads the program, and can flexibly access various equipment management platforms; 3. Realize remote control of industrial site touch screen and remote mapping of configuration screens; 4. PLC industry ...

HollySys PLC - What places should be avoided when installing PLC? HollySys PLC - What places should be avoided when installing PLC?

(1) The ambient temperature exceeds the range of 0-50 °C; (2) The relative humidity exceeds 85% or there is dew condensation (caused by sudden temperature changes or other factors); (3) direct sunlight; (4) There are corrosive and flammable gases, such as hydrogen chloride, ...

and Lisi plc - the difference between DCS and PLC and Lisi plc - the difference between DCS and PLC

The choice between a programmable logic controller (PLC) and a distributed control system (DCS) is a case-by-case analysis, as the requirements for the control system vary depending on the application. You can start from the following aspects! PLC and DCS PLC ...

Hollysys PLC - several common types of PLC control systems Hollysys PLC - several common types of PLC control systems

1. Stand-alone control system The stand-alone control system is controlled by one PLC to control one device or one simple production line, as shown in Figure 7-1. The composition of the stand-alone control system is simple, the number of I/O points required is less, the storage capacity is small, and when the model of PLC is selected, whether there is a communication network at present.

Hollysys PLC - PLC should be noted in operation (three, four, five) Hollysys PLC - PLC should be noted in operation (three, four, five)

3. Main anti-interference measures (1) Reasonable treatment of power supply to suppress the interference introduced by the power grid For grid disturbances introduced by the power supply, an isolation transformer with a shielded ratio of 1:1 can be installed to reduce the interference between the equipment and the ground.

Hollysys DCS - What are the specific contents of the major and minor repair projects of the DCS system? Hollysys DCS - What are the specific contents of the major and minor repair projects of the DCS system?

(1) Overhaul projects DCS system overhaul is carried out in the random group of main equipment overhaul, and the overhaul project includes the following: 1) Conduct a comprehensive inspection of the control equipment and make a record. 2) Copy the configuration of all modules, and verify the marks and addresses of the modules. 3) Qing ...

Hollysys PLC - what are the commonly used networking methods of PLC? Hollysys PLC - what are the commonly used networking methods of PLC?

1 Universal serial port module Based on the serial port communication module to realize the network connection, the network structure is shown in Figure 1, the form of computer link is adopted, the corresponding settings are carried out in the configuration software of the host computer, and the communication can be carried out with multiple PLCs without programming, and the FXlS of Mitsubishi ...

and Nesbitt DCS - the difference between SCADA and DCS and PLC and Nesbitt DCS - the difference between SCADA and DCS and PLC

To put it simply, DCS is mainly used for process automation, PLC is mainly used for factory automation (production lines), and SCADA is mainly for wide-area needs, such as oil fields and pipelines that stretch for thousands of miles. If from the point of view of computers and networks, they are unified, and the reason for the difference is mainly in ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top