Model M30 · Non-flush installation · M12 connector · 3 lines
KI5082 - Capacitive sensor, M30 x 1,5, Teach-in, electronic lock, automatic detection of PNP/NPN , DC PNP/NPN, sensing distance 20 mm, non-flush mounting, IP 65 / IP 67, ambient temperature -25...80 °C, M12 connector
KI5083 - Capacitive sensor, M30 x 1,5, Teach teach-in, electronic lock, DC PNP, sensing distance 20 mm, non-flush mounting, IP 65 / IP 67, ambient temperature -25...80 °C, M12 connector
Model M30 · Non-flush installation · 1/2" UNF connector · 2 lines
KI0054 - Capacitive sensor, M30 x 1,5, Teach-in, electronic lock, AC/DC, sensing distance 20 mm, non-flush mounting, IP 65 / IP 67, ambient -25...80 °C, 1/2" UNF connector
Model M30 · Non-flush installation · M12 connector · 4 lines
KN5121 - Level sensor, for dry loose materials (preferred: detection of plastic particles), 2 m HF-connection cable sensing distance, non-flush mounting, IP 67, ambient temperature -15...230 °C, M12 connector
Model M18 · Non-flush installation · M12 connector · 3 lines
KG5065 - Capacitive sensor, M18 x 1, Teach-in, electronic lock, automatic detection of PNP/NPN , DC PNP/NPN, sensing distance 12 mm, non-flush mounting, IP 65 / IP 67, ambient temperature -25...80 °C, M12 connector
KG5066 - Capacitive sensor, M18 x 1, DC PNP, sensing distance 12 mm, non-flush mounting, IP 65 / IP 67, ambient temperature -25...80 °C, M12 connector
|
More on that
|
Photoelectric sensor classification – ifm sensors
(1) Fork photoelectric sensor
Placing a light emitter and a sticker face to face on either side of a slot is a fork photonics. The luminaire can announce infrared or visible light, and the luminaire can receive light in an unobstructed environment. But when the object to be detected passes through the slot, the light is blocked ...
|
|
ifm IO-Link master and cabling system
The decentralised AS-i IO-Link master module acts as a gateway between the intelligent IO-Link sensor and the AS-Interface fieldbus. They combine the advantages of the AS-i cabling system with standard IO-Link communication. With IO-Link, connected sensors or actuators can be detailed ...
|
|
Installation and maintenance of ifm sensors
1. The wiring socket is connected at both ends of the inductance coil, and the other two ends are connected to the liquid level signal input end of the secondary instrument. When the inductor coil is open or the internal circuit is blocked, it should be replaced in time.
2. In order to commission and repair IFM ...
|
|
Load cell wiring method – ifm
There are four-wire and six-wire load cells. Four-wire system: EXC EXC: Power cord, that is, the DC power supply supplied by the instrument to the sensor. SIG, SIG-: The signal line, that is, the signal line output by the sensor, is output to the instrument. In addition to the above four lines, there are more than two in the four-wire system: SEN, SEN-: feedback line ...
|
|
Sensor performance indicators – ifm
Selection of sensitivity
In general, within the linear scale of the sensor, the higher the sensitivity of the sensor, the better. Because as long as the sensitivity is high, the value of the output signal corresponding to the measured change is relatively large, which is conducive to the signal processing.
|
|
What are the typical designs of torque sensors – ifm
Unlike load cells or force transducers, the measuring body of a torque transducer is not subjected to a tension load when used, but is torsionally affected by lever torque or torque. Therefore, torque sensors require special strain gauges to measure this type of load, i.e. torque. Canon...
|
|
ifm influences the sensor readings of gas detectors
Gas detector is an instrumentation tool for gas leakage concentration detection, which mainly uses sensors to detect the types of gases present in the environment, and gas sensors are used to detect the composition and content of gases.
Many environmental factors can affect gas detector sensing ...
|
|
IFM M12 DC Connectors & Cables Features:
IFM M12M12 DC connectors and cables
·“ OK in place" coupling nuts to withstand intense vibrations and shocks
Damage to fluoroelastomer o-rings caused by over-tightening can be avoided
· Construction data, tested ...
|
|
Load cell weighing reasons and connection to PLC – ifm
The principle of a load cell is that the gravity on the measured object is converted into a measurable output signal in a certain proportion.
The load cell can generally be connected to the PLC or the quadratic meter for the number display.
Regarding the use of PLC connection load cells in the factory, we generally have two ways to ...
|
|
ifm sensors detect objects contactlessly
Capacitive ifm sensors have many applications in everyday life. It is capable of inspecting non-metallic materials as well as non-touch methods to detect objects. The editor below explains how the sensor works.
Capacitive ifm sensors ...
|
|
What are the characteristics of smart sensors?
1. High precision and high quality
Assuming that the data information collected by the sensor makes a mistake, it is equivalent to making a mistake from the source, and the transmission, analysis and use of all the data behind it are meaningless, so the accuracy and quality of the sensor are guaranteed.
|
|
The cause of sensor interference – ifm
1. The PCB layout board touches the problem, and when the imitation signal is traced, the imitation signal is not wrapped with imitation, and there is even a possibility that the signal line is directly taken to the power line, which is easy to receive disturbance.
Solution: When it is a board, wrap the GND to imitate the signal line. If there is a model ...
|
|
The main classification of current sensors is ifm
(1) Resistance shunt: It is actually a resistance with a very small resistance value, when there is a current passage period, according to Ohm's law, the voltage occurs in the resistance, and the current size is known according to the measured voltage value. The resistance shunt has high precision, fast response, low cost, simple use, and disadvantages ...
|
|
How sensor detection avoids interference – ifm
Sensor detection is known to prevent disturbances. Once disturbed, the sensor may be damaged, the measurement system will be affected, the inaccurate data will affect the future use, the judgment will be biased, and the impact can be large or small, so anti-interference is very important. Today we're going to comment ...
|
|
A brief description of the features of ifm multi-code readers
Powerful detection function
The new multicomputer delivers 4x higher resolution for reliable reading results, 10x faster calculation times, and 10x faster setup.
Teach button
Its sensing ...
|
|
ifm stabilizes C-slot cylinder sensors
Easy-to-install sensor with long-service life electronic GMR unit – flush unit
This sensor can be conveniently installed in a C-slot
Fixed at the end of the housing for stable elastic stress relief
A variety of ...
|
|
The new radar level sensor LW2720 with IO-Link interface
In the food and beverage industry, level measurement of a wide range of tanks is critical, but there are many challenges.
For example, steam, condensate, temperature changes, or various gases (maintenance gases such as nitrogen) above the level surface in some tanks can affect the accuracy of the measurement.
|
|
Introduction to the ifm sensor classification
1. According to the input physical quantity, it can be divided into: displacement sensor, pressure sensor, speed sensor, temperature sensor and gas sensor.
2. According to the operating principle, it can be divided into: resistive, inductive, capacitive and ...
|
|
Precautions when switching the ifm on or off the power supply
The output status of the sensor when the power is turned on or off, whether it is detected or not, is OFF. In particular, when the power supply is turned on, the output condition is OFF for a certain period of time is called the initial reset. But in the following cases, the output will be momentarily ON(OFF) ...
|
|
Troubleshooting of high-frequency pressure sensors during operation
1. When the pressure goes up, the output of the transmitter can't go up.
In this case, you should first check whether the pressure connection is leaking or blocked. If you admit that it is not, check the wiring method and check the power supply, if the power supply is normal, then briefly pressurize to see if the output changes, or observe the zero position of the sensor ...
|
|