NR2 series thermal overload relay (hereinafter referred to as thermal relay) is suitable for AC 50Hz/60Hz, voltage to 690V, current (0.1-150)A long-term work or intermittent long-term operation of AC motor overload and phase failure protection.
The thermal relay also has the functions of temperature compensation, action indication, automatic and manual reset, stop, etc., and the product performance is stable and reliable. Thermal relays can be plugged in and installed with contactors or independently.
Comply with standards: GB/T 14048.4, GB/T 14048.5, IEC 60947-4-1.
project | NR2-11.5 | NR2-25 | NR2-36 | NR2-93 | NR2-150 | Current level | 13 | 25 | 36 | 93 | 150 | Rated insulation voltage V | 690 | 690 | 690 | 690 | 690 | Rated impulse withstand voltage V | 6000 | 6000 | 6000 | 6000 | 6000 | Enclosure rating | Ip20 | Ip20 | Ip20 | Ip20 | — | Phase-off protection | Yes | Yes | Yes | Yes | Yes | Manual vs. automatic reset | Yes | Yes | Yes | Yes | Yes | Temperature compensation | Yes | Yes | Yes | Yes | Yes | Trip indication | Yes | Yes | Yes | Yes | Yes | Test buttons | Yes | Yes | Yes | Yes | Yes | Stop button | Yes | Yes | Yes | Yes | Yes | Installation: | Plug-in | Plug-in | Plug-in | Plug-in | Plug-in | Auxiliary contacts | 1NO+1NC | 1NO+ 1NC | 1NO+1NC | 1NO+1NC | 1NO+ 1NC | AC-15 220V rated current A | 2.73 | 2.73 | 2.73 | 2.73 | 2.73 | AC-15 380V rated current A | 1.58 | 1.58 | 1.58 | 1.58 | 1.58 | DC-13 220V rated current A | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | The cross-sectional area of the conductor is mm² | Main circuit | Single core or stranded | 1~4 | 1~4 | 4~10 | 4~35 | 25~ 50 | Wire wiring screws | M3.5 | M4 | M4 | M10 | M6/ M8 | Auxiliary loops | Single core or stranded | 1~2.5 | 1~2.5 | 1~2.5 | 1~2.5 | 1~2.5 | Wire wiring screws | M3.5 | M3.5 | M3.5 | M3.5 | M3.5 | This article introduces CHINT/CHINT Motor Control & Protection Appliances -NR2 Series Thermal Relay Products If you are interested, please also contact our customer service, we are looking forward to your call, and hope that our technology and service can bring you a better experience.
The company has been customer-centric, the concept of creating value for customers, winning the market with quality and service, and sincerely hopes to cooperate with all sectors of society to create success, create brilliance together, and work together to create a better tomorrow! In line with the concept of credibility and service-oriented, the company warmly welcomes new and old customers to inquire, visit and negotiate business!
|
More on that
|
CHINT/CHINT Small Electromagnetic Relay NXJ Series Switching voltage 50VAC
Introduction: NXJ series miniature electromagnetic relay 2Z, 3Z, 4Z, 2ZH four contact forms: AC/DC specifications are complete; High contact reliability, can be used for PLC control; Transparent dust cover encapsulation; Equipped with matching sockets; Optionally available with status indicator.
...
|
|
CHINT/CHINT Relay NKG1 Time Control Switch AC220V, 50Hz
The NKG1 time-controlled switch is a control element of the time control unit, which can automatically turn on and off the power of various electrical equipment according to the time set by the user. The control object can be street lights, neon lights, advertising sign lights, production equipment, radio and television equipment, etc., all of which need to be turned on regularly.
|
|
CHINT/CHINT Time Relay JSS48A Series Time Delay Accuracy≤1%
Introduction: JSS48A series time relay is suitable for AC 50Hz, rated control power supply voltage to 380V and DC rated control power supply voltage to 240V as a time control element, according to the predetermined time to turn on or off the circuit.
...
|
|
CHINT/CHINT Small Electromagnetic Relay NJX2 Contact Resistance 100mQ
Introduction: NJX2 miniature electromagnetic relay 2Z, 3Z two contact forms; Contact switching current up to 10A; AC and DC specifications are complete; A variety of device sockets are available; It has mechanical locking, power-on indication and mechanical indication functions for selection.
...
|
|
CHINT/CHINT Pulse Relay NJMC1 size 86x 70x18mm
Introduction: NJMC1 pulse relay meets the requirements of GB/T 21711.1 standard; The NJMC1 pulse relay is a mechanical bistable relay that changes the state of the contact by inputting a pulse signal. Therefore, compared with ordinary relays, which have to be continuously energized when the armature is closed, pulse relay appliances ...
|
|
CHINT/CHINT Terminal Appliances —NXU-II. Surge Protective Devices
CHINT/CHINT Terminal Appliances —NXU-II. Surge Protector Main functions: lightning protection and surge protection in the inlet cabinet
Conform to the standard: GB/T18802.1
Basic parameters and technical performance indicators (Table 1)
Choose the appropriate specifications according to different grounding systems and protection modes. °L-PE/N-PE ...
|
|
CHINT/CHINT CJ40 Series AC Contactor CJ40-250
CJ40 series AC contactor (hereinafter referred to as contactor) is mainly used for switching and breaking circuits in power systems with AC 50Hz or 60Hz, rated voltage to 660V or 1140V, and current to 1000A.
|
|
CHINT/CHINT NJG2 Series Solid State Relay NJG2- SDA032- 10A220
Product Overview
The NJG2 Solid State Relay is a switching device that replaces contact with a semiconductor device. The input and output are photoelectically isolated, and when a control signal is added to the input, the output can be converted from a broken state to a connected state.
NJG2 solid state relay is widely used in electric furnace heating...
|
|
CHINT/CHINT Relay KG10D Time Control Switch AC220V , 50Hz
Product Overview
KG10D time-controlled switch can automatically turn on and off the power of various electrical equipment according to the time set by the user. The control object can be street lights, neon lights, advertising signs, production equipment, radio and television equipment, etc., all circuit equipment and home that need to be turned on and off regularly.
|
|
CHINT/CHINT JZ7 series intermediate relay
JZ7 series intermediate relay (hereinafter referred to as the relay) is mainly used in the control circuit of AC 50Hz (can be used for 60Hz after derivation), rated working voltage to 380V or DC rated working voltage to 220V, used to control various electromagnetic coils, so as to expand the signal or transmit the signal to the ...
|
|
CHINT/CHINT Terminal Appliance —NBH8-40□ Household Circuit Breaker
NBH8-40 □ household circuit breaker is mainly used for AC 50Hz, rated voltage to 230V, rated current to 40A line as overload and short circuit protection of power lines, and can also be used for infrequent switching of electrical devices and power lines under normal circumstances.
Standard: GB/T 10963 ...
|
|
CHINT/CHINT Terminal Appliance —NH8-125 Disconnector
NH8-125 isolating switch is mainly suitable for AC 50Hz, rated voltage to 415V, rated current 125A and below in the power distribution and control circuit, mainly as the terminal combination electrical appliances in the main switch, can also be used for infrequent control of all kinds of low-power electrical appliances and lighting, widely used in industrial and mining enterprises ...
|
|
CHINT/CHINT Time Relay NTE8 Series Reset time ≤1s
Introduction: NTE8 series time relay is mainly used as a time control component in the control circuit of AC 50Hz, rated control power supply voltage to 415V and DC rated control power supply voltage to 24V, and the circuit is turned on or off at a predetermined time.
...
|
|
CHINT/CHINT Small Electromagnetic Relay NJX3 has a rated voltage of 24VAC
Introduction: CHINT/CHINT miniature electromagnetic relay NJX3 has three contact forms: 1Z, 2Z and 3Z; Small structure, low power consumption, strong carrying capacity and high reliability; Widely used in the HVAC industry, it is used to control condensers, compressors, air conditioners and other equipment, and is the basic element in the air conditioning industry.
|
|
CHINT/CHINT NJG2 Series Solid State Relay NJG2- SDA032- 15A220
Product Overview
The NJG2 Solid State Relay is a switching device that replaces contact with a semiconductor device. The input and output are photoelectically isolated, and when a control signal is added to the input, the output can be converted from a broken state to a connected state.
NJG2 solid state relay is widely used in electric furnace heating...
|
|
CHINT/CHINT electromagnetic relay JQX-10F size 35x35x53mm
Introduction: JQX-10F small electromagnetic relay 2Z, 3Z two contact forms; Contact switching current up to 10A; AC and DC specifications are complete; It has a working status indication device; A variety of device sockets are available.
Product parameters
...
|
|
CHINT/CHINT Miniature Electromagnetic Relay NJDC-12 has a rated power consumption of 3VAC
Introduction: CHINT/CHINT small electromagnetic relay NJDC-12 has two contact forms: 2Z and 3Z; The contact switching current can reach 7.5A, and the AC and DC specifications are complete. With test button function, it can be jogged or closed and locked. A variety of device sockets are available.
...
|
|
CHINT/CHINT Motor Control & Protection Appliance - NR4 Series Thermal Overload Relay
NR4 series thermal overload relay (hereinafter referred to as thermal relay) is suitable for AC 50Hz/60Hz, rated voltage 690V, 1000V,
Overload and phase failure protection of AC motors with current (0.1-180)A for long-term operation or intermittent long-term operation.
Thermal relays have phase loss protection, ...
|
|
CHINT/CHINT JZC1 series contactor relays
JZC1 series contactor relay is mainly used in the control circuit of AC 50Hz or 60Hz, rated working voltage to 660V or DC rated working voltage to 600V, used to control various magnet coils and used for amplification and transmission of electrical signals.
|
|
CHINT/CHINT Time Relay NJS1 Series Time Delay Accuracy 0.5% Soil 50ms
Introduction: NJS1 series time relay is mainly used as a time control component in the control circuit of AC 50Hz, rated control power supply voltage to 380V and DC rated control power supply voltage to 240V, and the circuit is turned on or off at a predetermined time.
...
|
|