NKG3 series time-controlled switch is mainly used as a time control component in the circuit of AC 50Hz and rated control power supply voltage to 220V and below, which is used to turn on or off the circuit according to the predetermined program, and is used for timing on or off control of street lights, advertising light boxes and other equipment.
Main technology and parameter performance
Technical parameters | NKG3-M | NKG3 | Rated control supply voltage | AC220V , 50Hz | | The allowable fluctuation range of the rated control supply voltage | 85%~110% | | How it works | Manual on, manual off, automatic switch | Manual on, manual off, automatic switch;
The switching time can be automatically adjusted according to latitude; Daylight saving time function | Programmable number | 16 groups | | Time-controlled range | 1s~168h | 1 min ~24h | Timing error | Taxi 2s/d | | Output mode | 1 set of changeover contacts | | Contact capacity | Ue/Ie:AC-15 240V/3A,AC415V/1.9A;Ith: 16A | | Electrical life | 1x10ⁿ | | Mechanical life | 1x10" | | Ambient temperature. | -5°C ~40°C | | power consumption | <4. 5VA | | Installation: | Rail type | | This article introduces the CHINT/CHINT NKG3 time control switch products, if you are interested in CHINT/CHINT, please also contact our customer service, we are looking forward to your call, hope our technology and service can bring you a better experience.
The company has been customer-centric, the concept of creating value for customers, winning the market with quality and service, and sincerely hopes to cooperate with all sectors of society to create success, create brilliance together, and work together to create a better tomorrow! In line with the concept of credibility and service-oriented, the company warmly welcomes new and old customers to inquire, visit and negotiate business!
|
More on that
|
CHINT/CHINT NR5 series thermal overload relays
NR5 series thermal overload relay is suitable for AC 50Hz (or 60Hz), rated working voltage to 690V, working current 0.1-630A long-term work or intermittent long-term work of AC motor overload and phase failure protection, but also has temperature compensation, action indication, automatic ...
|
|
CHINT/CHINT Time Relay NJS1 Series Time Delay Accuracy 0.5% Soil 50ms
Introduction: NJS1 series time relay is mainly used as a time control component in the control circuit of AC 50Hz, rated control power supply voltage to 380V and DC rated control power supply voltage to 240V, and the circuit is turned on or off at a predetermined time.
...
|
|
CHINT/CHINT Relay KG316T Time Control Switch
Product Overview
KG316T series time-controlled switch is mainly used in the automatic control circuit of AC 50Hz, rated control power supply voltage to 220V, rated working current to 3A, as a regular switching on and off control of street lights, advertising light boxes and other equipment.
Technical data KG31 6T
Rated...
|
|
CHINT/CHINT CJ40 Series AC Contactor CJ40-250
CJ40 series AC contactor (hereinafter referred to as contactor) is mainly used for switching and breaking circuits in power systems with AC 50Hz or 60Hz, rated voltage to 660V or 1140V, and current to 1000A.
|
|
CHINT/CHINT Motor Control & Protection Appliance -JRS1 Series Thermal Overload Relay
JRS1 series thermal overload relay (hereinafter referred to as thermal relay) is mainly used for AC 50Hz/60Hz, voltage to 690V, current (0.1-80)A long-term work or intermittent long-term work AC motor overload and phase failure protection.
The thermal relay has phase failure protection, temperature compensation, dynamic ...
|
|
CHINT/CHINT NJG2 Series Solid State Relay NJG2- SDA032- 15A220
Product Overview
The NJG2 Solid State Relay is a switching device that replaces contact with a semiconductor device. The input and output are photoelectically isolated, and when a control signal is added to the input, the output can be converted from a broken state to a connected state.
NJG2 solid state relay is widely used in electric furnace heating...
|
|
CHINT/CHINT Terminal Appliance —NH8-125 Disconnector
NH8-125 isolating switch is mainly suitable for AC 50Hz, rated voltage to 415V, rated current 125A and below in the power distribution and control circuit, mainly as the terminal combination electrical appliances in the main switch, can also be used for infrequent control of all kinds of low-power electrical appliances and lighting, widely used in industrial and mining enterprises ...
|
|
CHINT/CHINT Miniature Electromagnetic Relay NJDC-12 has a rated power consumption of 3VAC
Introduction: CHINT/CHINT small electromagnetic relay NJDC-12 has two contact forms: 2Z and 3Z; The contact switching current can reach 7.5A, and the AC and DC specifications are complete. With test button function, it can be jogged or closed and locked. A variety of device sockets are available.
...
|
|
CHINT/CHINT Terminal Appliances — NH4-125 Disconnector
NH4-125 disconnector (hereinafter referred to as the switch) is suitable for AC 50Hz, rated current to 125A, rated voltage to 400V in the power distribution and control circuit, mainly as the main switch in the terminal combination electrical appliances, can also be used for infrequent control of various low-power electrical appliances and lighting, widely used in ...
|
|
CHINT/CHINT electromagnetic relay JQX-13F switching current 10A
Introduction: JQX-13F small high-power electromagnetic relay 10A contact switching capability; AC/DC specifications are complete; Transparent dust cover encapsulation, various installation methods; A variety of sockets are available; Optionally available with status indicator.
Give birth...
|
|
CHINT/CHINT JZC1 series contactor relays
JZC1 series contactor relay is mainly used in the control circuit of AC 50Hz or 60Hz, rated working voltage to 660V or DC rated working voltage to 600V, used to control various magnet coils and used for amplification and transmission of electrical signals.
|
|
CHINT/CHINT Terminal Appliances — Terminal Box — NX30H Series Distribution Box
NX30H series open/concealed distribution box (box) (hereinafter referred to as distribution box box) is an empty housing before installing 9mm modular terminal electrical components, suitable for circuits with rated voltage of 230V/400V and rated current to 100A. The installation mode of the distribution box box has two ...
|
|
CHINT/CHINT Thermal Overload Relay NXR Series Auxiliary Contacts 1NO+1NC
Introduction: NXR series thermal overload relay (hereinafter referred to as thermal relay) is suitable for AC 50Hz/60Hz, voltage to 690V, setting current 0.1-630A long-term work or intermittent work of AC motor overload and phase failure protection. Thermal relays also feature temperature compensation, action indication ...
|
|
CHINT/CHINT Terminal Appliances NX2 Series Distribution Box
NX2 series surface-mounted plastic distribution box (box) (hereinafter referred to as the box) is suitable for AC 50/60Hz, rated voltage 230V/400V, load current does not exceed 100A single-phase three-wire terminal circuit, as a power distribution and control of electrical equipment, but also for the overload of the line, short ...
|
|
CHINT/CHINT Motor Control & Protection Appliance -NR2 Series Thermal Relay
NR2 series thermal overload relay (hereinafter referred to as thermal relay) is suitable for AC 50Hz/60Hz, voltage to 690V, current (0.1-150)A long-term work or intermittent long-term operation of AC motor overload and phase failure protection.
The thermal relay also features temperature compensation, action indication, ...
|
|
CHINT/CHINT NJG2 Series Solid State Relay NJG2- SDA032- 10A220
Product Overview
The NJG2 Solid State Relay is a switching device that replaces contact with a semiconductor device. The input and output are photoelectically isolated, and when a control signal is added to the input, the output can be converted from a broken state to a connected state.
NJG2 solid state relay is widely used in electric furnace heating...
|
|
CHINT/CHINT Time Relay JSS48A Series Time Delay Accuracy≤1%
Introduction: JSS48A series time relay is suitable for AC 50Hz, rated control power supply voltage to 380V and DC rated control power supply voltage to 240V as a time control element, according to the predetermined time to turn on or off the circuit.
...
|
|
CHINT/CHINT Terminal Appliance SHT-X1 Deciter Tripper
Rated insulation voltage (Ui): 500V;
Rated operating current at different rated operating voltages (see Table 1)
Usage Category: AC-12, DC-12
Action characteristics: At 70%-10% of the rated control power supply voltage, the tripper should act reliably to disconnect the circuit breaker. Tripper ...
|
|
CHINT/CHINT Electromagnetic Relay JZX-22F Small Medium Power 250VAC
Introduction: JZX-22F small medium power electromagnetic relay 2Z, 3Z, 4Z three contact forms; AC/DC specifications are complete, and the installation methods are diverse; A variety of sockets are available, and there are specifications with indicator lights; Similar models: HH52P(-L), MY2(N), JZX-18F(L), HH53P...
|
|
CHINT/CHINT electromagnetic relay JQX-13FA contact resistance 100mΩ
Introduction: JQX-13FA small high-power electromagnetic relay 20A contact switching capability; AC/DC specifications are complete; Transparent dust cover encapsulation, various installation methods; A variety of sockets are available; Optionally available with status indicator.