Introduction: JQX-10F small electromagnetic relay 2Z, 3Z two contact forms; Contact switching current up to 10A; AC and DC specifications are complete; It has a working status indication device; A variety of device sockets are available.
Product parameters
Contact type: 2Z(C), 3Z(C)
Initial contact resistance: 100mΩ
Contact Material: Silver Alloy
Contact load (resistive): 10A/250VAC, 10A/30VDC
Maximum switching voltage: 250VAC/30VDC
Maximum switching current: 10A
Maximum switching power: 2500VA 300W
Electrical life (times): 1x10*5
Mechanical life (times): 1x10*7
Insulation resistance: 1 00MΩ (500VDC)
The medium is pressure-resistant
Between contact coils, between heterogeneous contacts: 1500VAC
Between disconnect contacts: 500VAC
Operating time (25°C, at rated voltage): ≤20ms
Release time (25°C, at rated voltage): ≤20ms
Impact stability: acceleration 1 00 m/s², pulse duration 11 ms
Vibration: double amplitude 1mm, (10- 55)Hz
Lead-out form: plug-in
Dimensions (mm): 35x35x53
This article introduces CHINT/CHINT electromagnetic relay JQX-10F size 35x35x53mm products, if you are interested in CHINT/CHINT electromagnetic relay, please also contact our customer service, we are looking forward to your call, hope our technology and service can bring you a better experience.
The company has been customer-centric, the concept of creating value for customers, winning the market with quality and service, and sincerely hopes to cooperate with all sectors of society to create success, create brilliance together, and work together to create a better tomorrow! In line with the concept of credibility and service-oriented, the company warmly welcomes new and old customers to inquire, visit and negotiate business!
|
More on that
|
CHINT/CHINT electromagnetic relay JQX-13F switching current 10A
Introduction: JQX-13F small high-power electromagnetic relay 10A contact switching capability; AC/DC specifications are complete; Transparent dust cover encapsulation, various installation methods; A variety of sockets are available; Optionally available with status indicator.
Give birth...
|
|
CHINT/CHINT NKG3 Time Control Switch AC220V, 50Hz
NKG3 series time-controlled switch is mainly used as a time control component in the circuit of AC 50Hz and rated control power supply voltage to 220V and below, which is used to turn on or off the circuit according to the predetermined program, and is used for timing on or off control of street lights, advertising light boxes and other equipment.
The main technology ...
|
|
CHINT/CHINT Small Electromagnetic Relay NXJ Series Switching voltage 50VAC
Introduction: NXJ series miniature electromagnetic relay 2Z, 3Z, 4Z, 2ZH four contact forms: AC/DC specifications are complete; High contact reliability, can be used for PLC control; Transparent dust cover encapsulation; Equipped with matching sockets; Optionally available with status indicator.
...
|
|
CHINT/CHINT Miniature Electromagnetic Relay NJDC-12 has a rated power consumption of 3VAC
Introduction: CHINT/CHINT small electromagnetic relay NJDC-12 has two contact forms: 2Z and 3Z; The contact switching current can reach 7.5A, and the AC and DC specifications are complete. With test button function, it can be jogged or closed and locked. A variety of device sockets are available.
...
|
|
CHINT/CHINT Relay Time Control Switch NJA1-L Relay (Intelligent Logic Controller)
NJA1-L relay is mainly used as a logic control element in the control circuit with AC frequency of 50Hz/60Hz, rated control power supply voltage to 240V and DC rated control power supply voltage to 240V or less, and performs relevant actions according to the set program.
Technical parameters: NJA1-L
Forehead...
|
|
CHINT/CHINT CJ40 Series AC Contactor CJ40-250
CJ40 series AC contactor (hereinafter referred to as contactor) is mainly used for switching and breaking circuits in power systems with AC 50Hz or 60Hz, rated voltage to 660V or 1140V, and current to 1000A.
|
|
CHINT/CHINT Motor Control & Protection Appliances - NRE8 Series Electronic Overload Relay
NRE8 series electronic overload relay (hereinafter referred to as the relay) is mainly used in the circuit with AC 50/60Hz, rated working voltage below 690V, and the current is within the range of the setting current calibrated by the casing, for three-phase motor overload and phase failure protection.
This relay is an application microcontroller ...
|
|
CHINT/CHINT JZC1 series contactor relays
JZC1 series contactor relay is mainly used in the control circuit of AC 50Hz or 60Hz, rated working voltage to 660V or DC rated working voltage to 600V, used to control various magnet coils and used for amplification and transmission of electrical signals.
|
|
CHINT/CHINT Electromagnetic Relay JZX-22F Small Medium Power 250VAC
Introduction: JZX-22F small medium power electromagnetic relay 2Z, 3Z, 4Z three contact forms; AC/DC specifications are complete, and the installation methods are diverse; A variety of sockets are available, and there are specifications with indicator lights; Similar models: HH52P(-L), MY2(N), JZX-18F(L), HH53P...
|
|
CHINT/CHINT Terminal Appliances NX2 Series Distribution Box
NX2 series surface-mounted plastic distribution box (box) (hereinafter referred to as the box) is suitable for AC 50/60Hz, rated voltage 230V/400V, load current does not exceed 100A single-phase three-wire terminal circuit, as a power distribution and control of electrical equipment, but also for the overload of the line, short ...
|
|
CHINT/CHINT Contactor Relay NXRC Series Insulation voltage 690V
Introduction: NXRC series contactor relays are mainly used in relay control, signal transmission, isolation amplification and other circuits with AC 50Hz or 60Hz, rated working voltage to 380V and DC rated voltage to 220V, for switching, breaking and amplifying.
...
|
|
CHINT/CHINT Terminal Appliance —NH8-125 Disconnector
NH8-125 isolating switch is mainly suitable for AC 50Hz, rated voltage to 415V, rated current 125A and below in the power distribution and control circuit, mainly as the terminal combination electrical appliances in the main switch, can also be used for infrequent control of all kinds of low-power electrical appliances and lighting, widely used in industrial and mining enterprises ...
|
|
CHINT/CHINT Pulse Relay NJMC1 size 86x 70x18mm
Introduction: NJMC1 pulse relay meets the requirements of GB/T 21711.1 standard; The NJMC1 pulse relay is a mechanical bistable relay that changes the state of the contact by inputting a pulse signal. Therefore, compared with ordinary relays, which have to be continuously energized when the armature is closed, pulse relay appliances ...
|
|
CHINT/CHINT Terminal Appliance SHT-X1 Deciter Tripper
Rated insulation voltage (Ui): 500V;
Rated operating current at different rated operating voltages (see Table 1)
Usage Category: AC-12, DC-12
Action characteristics: At 70%-10% of the rated control power supply voltage, the tripper should act reliably to disconnect the circuit breaker. Tripper ...
|
|
CHINT/CHINT Terminal Appliances — Terminal Box — NX30H Series Distribution Box
NX30H series open/concealed distribution box (box) (hereinafter referred to as distribution box box) is an empty housing before installing 9mm modular terminal electrical components, suitable for circuits with rated voltage of 230V/400V and rated current to 100A. The installation mode of the distribution box box has two ...
|
|
CHINT/CHINT electromagnetic relay JQX-13FA contact resistance 100mΩ
Introduction: JQX-13FA small high-power electromagnetic relay 20A contact switching capability; AC/DC specifications are complete; Transparent dust cover encapsulation, various installation methods; A variety of sockets are available; Optionally available with status indicator.
Give birth...
|
|
CHINT/CHINT Relay KG10D Time Control Switch AC220V , 50Hz
Product Overview
KG10D time-controlled switch can automatically turn on and off the power of various electrical equipment according to the time set by the user. The control object can be street lights, neon lights, advertising signs, production equipment, radio and television equipment, etc., all circuit equipment and home that need to be turned on and off regularly.
|
|
CHINT/CHINT NJG2 Series Solid State Relay NJG2- SDA032- 10A220
Product Overview
The NJG2 Solid State Relay is a switching device that replaces contact with a semiconductor device. The input and output are photoelectically isolated, and when a control signal is added to the input, the output can be converted from a broken state to a connected state.
NJG2 solid state relay is widely used in electric furnace heating...
|
|
CHINT/CHINT Time Relay JSS48A Series Time Delay Accuracy≤1%
Introduction: JSS48A series time relay is suitable for AC 50Hz, rated control power supply voltage to 380V and DC rated control power supply voltage to 240V as a time control element, according to the predetermined time to turn on or off the circuit.
...
|
|
CHINT/CHINT Relay KG316T Time Control Switch
Product Overview
KG316T series time-controlled switch is mainly used in the automatic control circuit of AC 50Hz, rated control power supply voltage to 220V, rated working current to 3A, as a regular switching on and off control of street lights, advertising light boxes and other equipment.
Technical data KG31 6T
Rated...
|
|