Introduction: CHINT/CHINT Plastic Housing Circuit Breaker NXB-125 is a new type of leakage circuit breaker integrating leakage relay, leakage circuit breaker, AC contactor, undervoltage and other functions. It can automatically distinguish between slowly variable leakage and abrupt leakage (electric shock) for protection
Product parameters
Rated current (In) : 63A, 80A, 100A, 125A;
Rated working voltage (Ue) : 230V—— (1P) ,400V—— (2P, 3P, 4P)
Rated insulation voltage (Ui) : 500V;
Frequency: 50Hz;
Electromagnetic Tripper Type: li=8In (Type C), li=12In (Type D);
Number of poles: 1P, 2P, 3P, 4P;
Mechanical life: 20000 times;
Electrical life: 6000 times(In≤100A); 4000 times (In> 100A) ;
Rated Limit Short Circuit Breaking Capacity (Icu) : 10kA;
Rated operating short circuit breaking capacity (Ics): 7.5kA;
Rated impulse withstand voltage (Uimp) : 4kV.
This article introduces CHINT/CHINT plastic case circuit breaker NXB-125 products, if you are interested in CHINT/CHINT circuit breaker, please also contact our customer service, we are looking forward to your call, hope our technology and service can bring you a better experience.
The company has been customer-centric, the concept of creating value for customers, winning the market with quality and service, and sincerely hopes to cooperate with all sectors of society to create success, create brilliance together, and work together to create a better tomorrow! In line with the concept of credibility and service-oriented, the company warmly welcomes new and old customers to inquire, visit and negotiate business!
|
More on that
|
CHINT/CHINT NSC1 Series Motion Controller NSC1-D16T
32-bit high-performance CPU, compiled execution mode, scan cycle is 10 times faster than analytical type, and the basic instruction single-step running time is 0.05μs.
Weight: 102
Power consumption: 2
Output Type: Transistor/Drain
Output voltage: 6-30VDC
**Large inductive load: 80VA
This article introduces the ...
|
|
CHINT/CHINT Terminal Block-TD Series
The TD series is suitable for connecting wires in power and control circuits with AC 50Hz or 60Hz, rated voltage up to 660V, and rated current up to 200A.
This series of terminal blocks are connected by screw crimping, and the wire end must be crimped with the TU type or TO type end before it can be connected with the terminal block. Pick up...
|
|
CHINT/CHINT NCH8G Household AC Contactor NCH8G-20/02
NCH8G series household AC contactor (hereinafter referred to as contactor) is mainly suitable for AC 50Hz (or 60Hz), rated working voltage to 400V rated working current to 63A circuit, control household appliances and similar uses of low-inductance and micro-inductance loads; It can also be used to control household ...
|
|
CHINT/CHINT NCH8G Household AC Contactor NCH8G-63/20
NCH8G series household AC contactor (hereinafter referred to as contactor) is mainly suitable for AC 50Hz (or 60Hz), rated working voltage to 400V rated working current to 63A circuit, control household appliances and similar uses of low-inductance and micro-inductance loads; It can also be used to control household ...
|
|
CHINT/CHINT NSD1 series servo drives
Servo drives, also known as "servo controllers" and "servo amplifiers", are a kind of controller used to control servo motors, and their functions are similar to those of inverters acting on ordinary AC motors. Servo drives are part of the servo system and are mainly used in high-precision ...
|
|
CHINT/CHINT NVF3G-LS series inverter single-phase 230V
Introduction: NVF3G-LS series special inverter for wire drawing is a cost-effective special inverter for the wire drawing and winding industry. NVF3G-LS series integrates winding control function, supports winding diameter calculation, tension PID control and wire break detection function, etc., so that the mechanical and electrical control system ...
|
|
CHINT/CHINT AL-X1H alarm contact
AL-X1H alarm contact is mainly used in the line with AC rated voltage to 415V or DC rated voltage to 130V, and is assembled with NBH-40 and NBH-63 series circuit breakers for signal indication of remote circuit breaker fault breaking.
The alarm contact is an accessory product that is assembled on the left side of the circuit breaker for use.
|
|
CHINT/CHINT YBLX-HL series travel switch YBLX-HL/5030
YBLX-HL travel switch is mainly used in the control circuit of AC 50Hz or 60Hz, voltage 380V, DC voltage 220V, for the travel control of the moving mechanism, the transformation of the direction or speed of the movement, the automatic control of the machine tool, the limit action of the moving mechanism and the control of the stroke or program.
Comply with the standard ...
|
|
CHINT/CHINT YBLX-WL series travel switch
YBLX-WL travel switch is mainly used in the control circuit of AC 50Hz or 60Hz, voltage 380V, DC voltage 220V, for the travel control of the moving mechanism, the transformation of the direction or speed of the movement, the automatic control of the machine tool, the limit action of the moving mechanism and the control of the stroke or program.
Accord with...
|
|
CHINT/CHINT CJ19 Series Switching Capacitor Contactor CJ19-95
CJ19 series switching capacitor contactor (hereinafter referred to as contactor) is mainly used in power lines with AC 50Hz (or 60Hz) and rated working voltage to 690V, which is used for low-voltage reactive power compensation equipment to put in or remove low-voltage shunt capacitors. Contactors with inhibition ...
|
|
CHINT/CHINT uninterruptible power supply HP-UPS series charging current 1A
Introduction: HP-UPS series online uninterruptible power supply is a high-frequency single-in, single-output online UPS model. Each capacity model is available in both standard and long-life models, with a wide range of applications, making it ideal for small space environments such as offices and computer rooms. It can be used for small data centers, storage, network ...
|
|
CHINT/CHINT Terminal Appliance OUVR-2 Self-resetting Over/Under Voltage Protector
OUVR-2 self-resettable over-under-voltage protector is a new type of intelligent protection electrical appliances, the product adopts modular standard design, when the power supply line appears over-voltage, under-voltage, the protector can quickly and safely cut off the circuit under the continuous high-voltage impact, to avoid abnormal voltage sent to the terminal electrical appliances to cause accidents.
|
|
CHINT/CHINT NXBLE-125 residual current action circuit breaker
CHINT/CHINT NXBLE-125 residual current action circuit breaker
Rated current (In): 63A, 80A, 100A, 125A (1P+N, 2P);
Rated Residual Operating Current (IOn) : AC type: 0.03A, 0.05A, 0.075A, 0.1A, 0.3A; Type A: 0.03A, ...
|
|
CHINT/CHINT Terminal Appliances —NB7 Series Miniature Circuit Breaker
NB7 series miniature circuit breaker is suitable for overload and short circuit protection in the line of AC 50Hz, rated voltage to 400V, rated current to 63A, can be used as infrequent operation conversion of the line under normal circumstances, and can also be used as an isolation switch for disconnecting the line for line and equipment maintenance.
|
|
CHINT/CHINT NB8LE-63 residual current action circuit breaker
NB8LE-63 residual current action circuit breaker is mainly suitable for AC 50Hz, rated voltage to 400V, rated current to 63A in commercial office buildings, residential and general industrial terminal distribution lines, to provide overload, short circuit protection and leakage protection for the line, but also in normal conditions ...
|
|
CHINT/CHINT NXBF-125 plastic case circuit breaker
NXBF-125 plastic shell circuit breaker is suitable for AC 50Hz, rated voltage 230V/400V, rated current to 125A in the line, for overload and short circuit protection, under normal circumstances, as the line of infrequent operation and conversion, can also be used as a disconnection line for line and equipment maintenance...
|
|
CHINT/CHINT NB1L (10kA) residual current operated circuit breaker
NB1L residual current action circuit breaker is suitable for AC 50Hz, rated voltage 230V, rated current to 40A line, when the person is electrocuted or the leakage current of the power grid exceeds the specified value, the residual current action circuit breaker can quickly cut off the fault power supply in a very short time, protect people and electrical equipment...
|
|
CHINT/CHINT CKJ5 Series Vacuum AC Contactor CKJ5-160
CKJ5 series vacuum AC contactor (hereinafter referred to as contactor) is mainly used in AC 50Hz, rated working voltage to 1140V, rated working current to 630A circuit, for long-distance connection and breaking of circuits, and can be used with appropriate thermal overload relay or electronic protection ...
|
|
CHINT/CHINT HY23 series reverse switch
HY23 series instead of HZ3 series combination switch is suitable for AC 50Hz or 60Hz, voltage 380V circuit, as a power supply introduction switch, or as a three-phase squirrel cage induction motor with a control operation frequency of no more than 300 times per hour.
Standards: GB/T 14048.3, IEC 60947-3 ...
|
|
CHINT/CHINT NH5-125 disconnector
NH5-125 disconnector is mainly suitable for AC 50Hz, rated voltage to 400V, rated current 125A and below in the power distribution and control circuit, mainly as the main switch in the terminal combination electrical appliances, can also be used for infrequent control of various low-power electrical appliances and lighting, widely used in industrial and mining ...
|
|