CHINT/CHINT NXBLE-125 residual current action circuit breaker
Rated current (In): 63A, 80A, 100A, 125A (1P+N, 2P);
Rated Residual Operating Current (IOn) : AC type: 0.03A, 0.05A, 0.075A, 0.1A, 0.3A; Type A: 0.03A, 0.1A, 0.3A;
Rated working voltage (Ue): 230V-(1P+N, 2P), 400V-(3P, 3P+N, 4P);
Rated insulation voltage (Ui) : 500V ;
Frequency: 50Hz;
Electromagnetic Tripper Type: li=8In( Type C), li=12In(Type D);
Overvoltage protection range value ( Uvo} :(280±14)V
Number of poles: 1P+N, 2P, 3P, 3P+N, 4P
Mechanical life: 20000 times;
Electrical life: 6000 times ( Ins100A ), 4000 times {In> 100A );
Rated limit short-circuit breaking capacity ( lcu) : 10kA ;
Rated operating short circuit breaking capacity (Ics) : 7.5kA ;
Rated impulse withstand voltage (Uimp): 4kV.
This article introduces CHINT/CHINT NXBLE-125 residual current action circuit breaker products interested, also contact our customer service, we look forward to your call, hope our technology and service can bring you a better experience.
The company has been customer-centric, the concept of creating value for customers, winning the market with quality and service, and sincerely hopes to cooperate with all sectors of society to create success, create brilliance together, and work together to create a better tomorrow! In line with the concept of credibility and service-oriented, the company warmly welcomes new and old customers to inquire, visit and negotiate business!
|
More on that
|
CHINT/CHINT DZ20 series plastic case circuit breaker
DZ20 series plastic shell circuit breaker (hereinafter referred to as circuit breaker), its rated insulation voltage is 660V, AC 50Hz, rated working voltage 380V and below, and its rated current is from 32A to 1250A. Generally used for power distribution, the rated current of type C is 160A and below, and the shell of type 630 and below ...
|
|
CHINT/CHINT NVF3G-QZ series special inverter for lifting wall mounting
Introduction: NVF3G-QZ series products are the company's special inverter specially designed for the application characteristics and control requirements of the lifting industry, using advanced vector control technology and torque control technology, with fast load dynamic response, large low-frequency torque, strong overload capacity and other characteristics, and integration ...
|
|
CHINT/CHINT DZ20 Series Plastic Case Circuit Breaker DZ20Y-1250
DZ20 series plastic shell circuit breaker (hereinafter referred to as circuit breaker), its rated insulation voltage is 660V, AC 50Hz, rated working voltage 380V and below, and its rated current is from 32A to 1250A. Generally used for power distribution, the rated current of type C is 160A and below, and the shell of type 630 and below ...
|
|
CHINT/CHINT NCH8G Household AC Contactor NCH8G-20/01
NCH8G series household AC contactor (hereinafter referred to as contactor) is mainly suitable for AC 50Hz (or 60Hz), rated working voltage to 400V rated working current to 63A circuit, control household appliances and similar uses of low-inductance and micro-inductance loads; It can also be used to control household ...
|
|
CHINT/CHINT Terminal Appliance UVT-X1 Undervoltage Tripper
Rated Operating Voltage (Ue) : AC 230V , 50Hz;
Rated insulation voltage (Ui): 500V;
Undervoltage action setting value: (35%-70%) Ue;
Action characteristics: the external voltage ≤35%Ue, and the product should prevent the circuit breaker from closing; 35%Ue≤ external voltage ...
|
|
CHINT/CHINT NC7 Series AC Contactor Free air heating current 20A
Introduction: CHINT/CHINT AC contactor NC7-09 (hereinafter referred to as contactor) is mainly used for AC 50Hz (or 60Hz), rated working voltage to 690V, in the AC-3, 400V use category rated working current to 620A circuit, mainly used for long-distance connection and breaking circuits...
|
|
CHINT NB3LE-63M residual current action circuit breaker
This product is suitable for AC 50Hz, rated voltage 230V, rated current to 63A line, play overload, short circuit and leakage protection, can also be used as infrequent line on/off under normal circumstances.
Conform to the standard: GB/T 16917.1 IEC 61009-1, obtained CCC certification...
|
|
CHINT/CHINT Terminal Appliance —NH3-63 Disconnector
NH3-63 disconnector (hereinafter referred to as the switch) is suitable for AC 50Hz, rated voltage 230V, rated current to 63A resistance circuit, mainly for no load to turn on or off the circuit, for the line and power supply to be connected or isolated. It is especially suitable for effective isolation of power supply during line maintenance ...
|
|
CHINT/CHINT HY2 series reverse switch
HY2 series reverse switch (hereinafter referred to as switch) is mainly suitable for AC 50Hz (or 60Hz), rated working voltage to 380V, rated working current to 20A motor circuit, used as a direct switch on and off a single squirrel cage induction motor, so that it rotates, reverses and stops.
Compliant with standards ...
|
|
CHINT/CHINT NXBLE-63ZB self-diagnostic residual current action circuit breaker
During the working process, the leakage protection function is regularly diagnosed by itself (detected every 108 minutes), and the user will be reminded through the alarm module when the leakage protection function of the product is abnormal
Rated current (In): 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A;
Rated ...
|
|
CHINT/CHINT Miniature Circuit Breaker NXB-125G Quota voltage 230V
Introduction: CHINT/CHINT miniature circuit breaker NXB-125G is a new type of leakage circuit breaker integrating leakage relay, leakage circuit breaker, AC contactor, undervoltage and other functions. It can automatically distinguish between slowly variable leakage and abrupt leakage (electric shock) for protection
Product parameters
...
|
|
CHINT/CHINT NA1 series universal circuit breaker
NA1 series universal circuit breaker (hereinafter referred to as circuit breaker) is suitable for AC 50Hz, rated working voltage to AC690V, rated working current to 6300A and below in the distribution network, used to distribute electric energy and protect lines and power equipment from overload, undervoltage, short circuit, single-phase grounding, etc.
|
|
CHINT/CHINT NBH-40 miniature circuit breaker
NBH-40 miniature circuit breaker is mainly used for overload and short circuit protection of power lines in household and similar places with AC 50Hz, rated voltage to 230V and rated current to 40A, and can also be used for infrequent switching of electrical devices and power lines under normal circumstances.
Products...
|
|
CHINT/CHINT NSC1 Series Motion Controller NSC1-D8T
32-bit high-performance CPU, compiled execution mode, scan cycle is 10 times faster than analytical type, and the basic instruction single-step running time is 0.05μs.
Weight: 102
Power consumption: 2
Digital inputs: 8
Output voltage: 6-30VDC
Maximum inductive load: 12W
Maximum Resistance Load: Single-point maximum ...
|
|
CHINT/CHINT Button & Signal Light NDT1 Series Warning Light
NDT1 series warning light, with integrated multi-layer structure, is suitable for indication, warning, fault and other indication signals in telecommunications, electrical and other lines with AC 50Hz (or 60Hz), rated working voltage of 220V and below or DC working voltage of 24V and below. Wide range of applications ...
|
|
CHINT/CHINT AX-5 auxiliary contacts
The AX-5 auxiliary contact is suitable for AC 50Hz, the agreed heating current to 6A, the rated voltage to 415V or the DC rated voltage to 130V, and it is assembled with the NL1 residual current action circuit breaker for the signal indication of the long-distance circuit breaker.
Conform to the standard: GB/T 14048.5, ...
|
|
CHINT/CHINT Miniature Circuit Breaker NXB-80 withstand voltage 4kV
Introduction: CHINT/CHINT miniature circuit breaker NXB-125G is a new type of leakage circuit breaker integrating leakage relay, leakage circuit breaker, AC contactor, undervoltage and other functions. It can automatically distinguish between slowly variable leakage and abrupt leakage (electric shock) for protection
Product parameters
...
|
|
CHINT /CHINT NP9 button
The NP9 button is suitable for AC 50Hz/60Hz, rated voltage to 230V circuit control system, as a magnetic starter, contactor and other electrical circuit control. The illuminated button is also suitable for various places indicated by light signals.
Standards: GB/T 14048.5, IEC 60947-5 ...
|
|
CHINT/CHINT AL-X1H alarm contact
AL-X1H alarm contact is mainly used in the line with AC rated voltage to 415V or DC rated voltage to 130V, and is assembled with NBH-40 and NBH-63 series circuit breakers for signal indication of remote circuit breaker fault breaking.
The alarm contact is an accessory product that is assembled on the left side of the circuit breaker for use.
|
|
CHINT/CHINT OVT-1 overvoltage tripper
OVT-1 overvoltage tripper is mainly used for overvoltage protection in lines with AC 50Hz (60Hz) and rated working voltage of 230V.
Ambient temperature: -25°C - +60°C
Relative humidity: ≤95%
Pollution level: Level 3
Altitude:...
|
|