Introduction: NVF3G-LS series special inverter for wire drawing is a cost-effective special inverter for the wire drawing and winding industry. The NVF3G-LS series integrates the winding control function, which supports the functions of winding diameter calculation, tension PID control and wire break detection function, which makes the mechanical and electrical control system more simplified.
Product parameters
input
Rated voltage: three-phase: (380-440)V; Single-phase: 230V
Frequency: 50Hz/60Hz
Voltage range: three-phase: 380V (-15%) - 440V (+15%) single-phase: 230V (±15%)
Frequency range: (47-63)Hz
output
Voltage: 0 - rated input voltage
Frequency: (0-300) Hz
Overload capacity: 150% rated current for 1 minute, 180% rated current for 2 seconds
The main control performance
Control mode: no PG vector control (SVC) with PG vector control (FVC) V/F control
Modulation: Space vector PWM modulation
Starting torque: 150% rated torque at 0.5Hz (without PG vector control) 200% rated torque at 0.00Hz (with PG vector control)
Frequency Resolution: Digital Setting: 0.01Hz, Analog Setting: Maximum Frequency×0.5%
Torque lifting: automatic torque lifting, manual torque lifting
V/F curve: 6 methods: straight V/F curve, 3 torque reduction characteristic curve methods (2.0 power, 1.7 power, 1.2 power), multi-point V/F curve method, and V/F separation curve method
Acceleration and deceleration curves: Linear acceleration and deceleration (4 types), S-curve acceleration and deceleration
Automatic current limiting: The current is automatically limited during operation to prevent frequent overcurrent fault tripping
Special functions for wire drawing: main speed calculation function, coil diameter calculation function, tension PID function, wire break detection function
Run the function
Running command channel: the operation panel is given, the control terminal is given, and the communication control can be switched in a variety of ways
Digital inputs: 7 multi-function digital programmable inputs (including 1 high-speed pulse input terminal)
Digital outputs: 2 multi-function digital programmable outputs (up to 100kHz)
Analog input: 3 analog signal inputs, optional (0-20)mA, (4-20)mA current signal input or (-10-+10)V voltage signal input
Analog output: 2 analog signal outputs, (0-20) mA, (4-20) mA current output or (0-10) V voltage output can be selected respectively, which can realize the output of physical quantities such as set frequency and output frequency
Relay output: 2 relay outputs, 1 normally open and normally closed, 1 normally open. Contact Capacity: NO 5A /NC 3A 250V (AC)
Operator panel
LED display: It can display more than 20 parameters such as set frequency, output frequency, output voltage, output current, etc
Key Lock: Locks all or part of the key
Function selection: Define the scope of action of some keys to prevent misoperation
Protection function: It has protection functions such as over-current protection, over-voltage protection, under-voltage protection, over-temperature protection, overload protection, and phase loss protection
structure
Degree of protection: IP20
Cooling method: Axial DC fan cooling
Installation: wall-mounted
Efficiency: 93% ≥ 37kW and below; 45kW and above≥ 95%
We will provide customers with high-quality products and satisfactory services with honest and trustworthy, convenient and fast business methods and strict management.
This article introduces CHINT/CHINT NVF3G-LS series inverter single-phase 230V products, if you are interested in CHINT/CHINT inverter, please also contact our customer service, we look forward to your call, hope our technology and service can bring you a better experience.
|
More on that
|
CHINT/CHINT CJ19 Series Switching Capacitor Contactor
CJ19 series switching capacitor contactor (hereinafter referred to as contactor) is mainly used in power lines with AC 50Hz (or 60Hz) and rated working voltage to 690V, which is used for low-voltage reactive power compensation equipment to put in or remove low-voltage shunt capacitors. Contactors with inhibition ...
|
|
CHINT/CHINT CKJ5 Series Vacuum AC Contactor CKJ5-160
CKJ5 series vacuum AC contactor (hereinafter referred to as contactor) is mainly used in AC 50Hz, rated working voltage to 1140V, rated working current to 630A circuit, for long-distance connection and breaking of circuits, and can be used with appropriate thermal overload relay or electronic protection ...
|
|
CHINT/CHINT switch NZ7 series rated working voltage 400ACV 50HZ
Introduction: NZ7 series automatic transfer switch electrical appliances are suitable for AC power frequency 50Hz, rated working voltage AC400V, rated working current to 800A in the three-phase four-wire dual-circuit power supply network, automatically connect one or several load circuits from one power supply to another, in order to ensure that the load circuit is positive...
|
|
CHINT/CHINT NBHLE-63Y residual current action circuit breaker
NBHLE-63Y residual current action circuit breaker is suitable for AC 50Hz, rated voltage 230V, rated current to 63A line, play the role of overload, short circuit and leakage protection, can also be used as infrequent line on/off under normal circumstances.
The product conforms to IEC61009-1, GB/T 1691 ...
|
|
CHINT/CHINT CJ20 Series AC Contactor CJ20-63
CJ20 series AC contactor (hereinafter referred to as contactor) is mainly used in AC 50Hz (or 60Hz), rated working voltage to 660V, rated working current to 630A, for long-distance switching and breaking circuits, and can be combined with appropriate thermal overload relays.
|
|
CHINT NBHLE-32 residual current action circuit breaker
NBHLE-32 residual current action circuit breaker is suitable for AC 50Hz, rated voltage 230V/400V, rated current to 32A in the line, play the role of overload, short circuit and leakage protection, can also be used as infrequent on-off of the line under normal circumstances.
The product conforms to IEC61009-1, GB/T...
|
|
CHINT/CHINT NVF2G series inverter IP20 protection grade
Introduction: NVF2G series inverter is a high-performance open-loop vector inverter independently developed by our company. It has the characteristics of large starting torque (0.5Hz, 1.5 times rated torque), strong overload capacity, flexible and convenient operation, forward and reverse PID, etc. This series of inverters is divided into mini, general purpose (heavy duty) and ...
|
|
CHINT/CHINT Terminal Appliance —DZ158-125□ Plastic Case Circuit Breaker
DZ158-125□ plastic shell circuit breaker is mainly used for AC 50Hz, single pole 230V, two, three and four pole 400V; In the line with rated current of 63A to 125A, it is used for overload and short circuit protection of power lines, and can also be used to turn on and off electrical devices and power lines infrequently under normal conditions.
|
|
CHINT/CHINT switch NXZ series rated insulation voltage AC800v
Introduction: NXZ series automatic transfer switch electrical appliances are suitable for AC 50Hz, rated voltage 400V/415V and below, rated current to 630A three-phase four-wire dual-circuit power supply grid, automatically connect one or several load circuits from one power supply to another, in order to ensure the normal supply of load circuits.
|
|
CHINT/CHINT NXBLE-63 residual current operated circuit breaker
CHINT/CHINT NXBLE-63 residual current operated circuit breaker
Rated current (In): 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A;
Rated residual operating current (I△n): 0.01A (1P+N, 2P), 0.03A, 0.05A, 0.075A, 0.1A, 0.3A (AC type); 0.03 ...
|
|
CHINT/CHINT Authorized Complete Product — POWGRID-F Series Terminal Box
The POWGRID-F series terminal box is suitable for circuits with AC 50Hz or 60Hz, rated voltage of 230V/400V AC, rated current/maximum continuous input current of no more than 125A, and the maximum power consumption capacity of the cabinet is 35W. It can be widely used in real estate - residential, commercial construction, hotels and public buildings.
Technology...
|
|
CHINT/CHINT S9 shunt tripper
The S9 shunt trip device (hereinafter referred to as the tripper) is mainly used for matching with NB1 or NBH8 series circuit breakers, and is suitable for long-distance shunt tripping operation in lines with AC 50Hz (or 60Hz) rated voltage to 400V.
Meets the standard: IEC60947-5-1, obtained CE certification.
3.1 Basic ...
|
|
CHINT/CHINT HY23 series reverse switch
HY23 series instead of HZ3 series combination switch is suitable for AC 50Hz or 60Hz, voltage 380V circuit, as a power supply introduction switch, or as a three-phase squirrel cage induction motor with a control operation frequency of no more than 300 times per hour.
Standards: GB/T 14048.3, IEC 60947-3 ...
|
|
CHINT/CHINT NB1LE-40□ residual current operated circuit breaker
NB1LE-40□ residual current action circuit breaker is suitable for AC 50Hz, rated voltage single pole two wires, two poles 230V, three poles, three poles four wires, four poles 400V, rated current to 40A line, when the person is electrocuted or the leakage current of the power grid exceeds the specified value, the residual current action circuit breaker can be ...
|
|
CHINT/CHINT YBLX-HL series travel switch
YBLX-HL travel switch is mainly used in the control circuit of AC 50Hz or 60Hz, voltage 380V, DC voltage 220V, for the travel control of the moving mechanism, the transformation of the direction or speed of the movement, the automatic control of the machine tool, the limit action of the moving mechanism and the control of the stroke or program.
Comply with the standard ...
|
|
CHINT/CHINT NB8LE-40 residual current action circuit breaker
NB8LE-40 residual current action circuit breaker is mainly suitable for AC 50Hz, rated voltage to 230V, rated current to 40A in commercial office buildings, civil residential and general industrial terminal distribution lines, to provide overload, short circuit protection and leakage protection for the line, but also in normal conditions ...
|
|
CHINT/CHINT NB1L(6kA) residual current operated circuit breaker
NB1L residual current action circuit breaker is suitable for AC 50Hz, rated voltage 230V, rated current to 25A line, when the person is electrocuted or the power grid leakage current exceeds the specified value, the residual current action circuit breaker can quickly cut off the fault power supply in a very short time, protect people and electrical equipment...
|
|
CHINT/CHINT YBLX-WL series travel switch
YBLX-WL travel switch is mainly used in the control circuit of AC 50Hz or 60Hz, voltage 380V, DC voltage 220V, for the travel control of the moving mechanism, the transformation of the direction or speed of the movement, the automatic control of the machine tool, the limit action of the moving mechanism and the control of the stroke or program.
Accord with...
|
|
CHINT/CHINT NB2LE residual current action circuit breaker
NB2LE residual current action circuit breaker is suitable for residual current protection, overload and short circuit protection in lines with AC 50/60Hz, rated voltage of 230V and rated current up to 40A. When the person is electrocuted or the leakage current of the circuit exceeds the specified value, the residual current action circuit breaker can be used in a very short ...
|
|
CHINT/CHINT New Series NB5 Accessories
SHT-B5 shunt tripper (hereinafter referred to as tripper) is mainly used for matching with NB5 series circuit breakers, and is suitable for long-distance shunt tripping operation in lines with AC 50Hz and rated voltage to 415V;
AX-B5 auxiliary contact is mainly used for AC 50Hz, rated heating current to 6A, rated ...
|
|