(1) High reliability

DCS is designed to be fault-tolerant, so that when a computer fails, it does not cause the system to lose other functions. In addition, because the tasks undertaken by each computer in the system are relatively simple, it is possible to use a dedicated computer with a specific structure and software for the functions that need to be implemented, thereby improving the reliability of each computer in the system.

(2) Openness

DCS adopts open, standardized, modular and serial design, each computer in the system adopts LAN mode communication to achieve information transmission, when it is necessary to change or expand the system function, the new computer can be easily connected to the system communication network or removed from the network, almost does not affect the work of other computers in the system.

(3) Flexibility

The software and hardware are configured according to different process application objects through the configuration software, that is, the measurement and control signals and the connection relationship between them are determined, the applicable control laws are selected from the control algorithm library and the various monitoring and alarm screens required by the basic graphics are called from the graphics library, so as to conveniently constitute the required control system.

(4) Easy to maintain

Small or micro special computer with a single function, with the characteristics of simple maintenance and convenience, when a part or a computer fails, it can be replaced online without affecting the operation of the whole system, and the fault can be quickly eliminated.

(5) Coordination

Each workstation transmits various data through the communication network, and the whole system information is shared and coordinated to complete the overall function and optimization of the control system.

(6) The control function is complete

The control algorithm is abundant, integrating continuous control, sequential control and batch control, which can realize advanced control such as cascade, feedforward, decoupling, adaptive and predictive control, and can easily add the required special control algorithms.
Hollysys DCS - Introduction to the main features of DCS

More on that
Hollysys DCS – the steps for DCS to properly power off and power on Hollysys DCS – the steps for DCS to properly power off and power on

DCS is properly blacked out When the DCS needs to be powered off for maintenance due to overhaul or other reasons, we often directly power off the DCS, but sometimes this non-standard operation will bring serious consequences, such as configuration loss, PID parameter loss, etc. So there is a need for blackouts and re-on...

Hollysys PLC - the six application functions of PLC Hollysys PLC - the six application functions of PLC

1. It is used for switching control The ability of PLC to manipulate switching quantities is very strong. The number of points in and out of the control, less than a dozen points, dozens of points, more can be hundreds, thousands, or even tens of thousands of points, because it can be networked, the number of points is almost unlimited, no matter how many points can be controlled, the control ...

Hollysys PLC - Electrical troubleshooting of PLC control loop Hollysys PLC - Electrical troubleshooting of PLC control loop

In general, PLCs are extremely reliable devices with a very low failure rate. The probability of hardware damage such as the CPU of the PLC or software running errors is almost zero; If the PLC input point is not caused by strong current intrusion, it will hardly be damaged; The normally open point of the PLC output relay, if it is not a short circuit of the peripheral load ...

Hollysys DCS - a common fault of DCS Hollysys DCS - a common fault of DCS

1. Field instrument equipment failure: Field instrumentation equipment includes various transmitters, various switches, actuators, loads and components of various temperatures that are directly connected with the production process. If the field instrument fails, it directly affects the control function of the DCS system and the operator's ...

Hollysys PLC - Introduction to the working principle and operation mode of PLC controller Hollysys PLC - Introduction to the working principle and operation mode of PLC controller

How a PLC controller works 1. Scanning technology When the PLC is put into operation, its working process is generally divided into three stages, namely input sampling, user program execution and output refresh. The completion of these three phases is called a scan cycle. During the entire operation ...

Hollyps PLC - the control method of PLC and frequency converter connection Hollyps PLC - the control method of PLC and frequency converter connection

1. Use the analog output module of the PLC to control the analog output module of the inverter The analog output module of the PLC outputs a 0-5V voltage signal or a 4-20mA current signal, which is used as the analog input signal of the inverter to control the output frequency of the inverter. This control method is simple to wiring, but it needs to be selected and changed.

Hollysys PLC – How to calculate the analog quantity in PLC Hollysys PLC – How to calculate the analog quantity in PLC

1、-10—10V。 When the voltage of -10V-10V is converted to F448-0BB8Hex (-3000-3000) at 6000 resolution; At 12000 resolution, it is converted to E890—1770Hex (-6000—6000). 2、0—10V。 At a voltage of 0-10V, at a resolution of 12000 ...

and Lisi plc - the difference between DCS and PLC and Lisi plc - the difference between DCS and PLC

The choice between a programmable logic controller (PLC) and a distributed control system (DCS) is a case-by-case analysis, as the requirements for the control system vary depending on the application. You can start from the following aspects! PLC and DCS PLC ...

What are the functions of Hollysys PLC - PLC data acquisition gateway? What are the functions of Hollysys PLC - PLC data acquisition gateway?

1. Rich networking and interface functions, easy to deploy It supports 5G/4G/3G/WIFI/Ethernet, WAN/optical fiber and other network access modes, network port/serial port/IO port/CAN port and other equipment access, and supports LoRa wireless transmission, disconnection reconnection and multi-network mutual backup function. 2. Abundant ...

Hollysys plc - the difference between DCS and PLC Hollysys plc - the difference between DCS and PLC

1. DCS is a "distributed control system", while PLC (programmable controller) is just a control "device", which is the difference between the two. The system can realize the function and coordination of any equipment, and the PLC equipment only realizes the function of this unit. 2. In terms of networking, the DCS network is ...

Hollysys DCS - DCS daily maintenance and fault analysis and troubleshooting methods Hollysys DCS - DCS daily maintenance and fault analysis and troubleshooting methods

01. Power supply The DCS power supply system is mostly a "dual backup hot redundant power supply", and the prevention and control of power failures is mainly reflected in the inspection and daily maintenance. Generally speaking, as long as the unit is normal ...

Hollysys DCS - Introduction to the hardware architecture of DCS Hollysys DCS - Introduction to the hardware architecture of DCS

Examining the hierarchical structure of DCS, DCS level and control management level are the two most basic links that make up DCS. The process control stage specifically realizes the decentralized control functions such as signal input, conversion, operation and output. The controls at the process control level vary in different DCS, ...

Hollysys PLC - What are the communication methods between PLC and inverter? Hollysys PLC - What are the communication methods between PLC and inverter?

1. The switching signal of PLC controls the inverter The output point and COM point of the PLC (MR type or MT type) are directly connected to the STF (forward start), RH (high speed), RM (medium speed), RL (low speed), and SG input ports of the inverter. PLC can control the frequency conversion through the program ...

Hollysys' 100% domestic PLC has achieved breakthrough applications in the field of nuclear power Hollysys' 100% domestic PLC has achieved breakthrough applications in the field of nuclear power

Hollysys, as the PC general contractor, participated in the construction of the first smart water project in the domestic nuclear power industry (1) - Qin's No. 2 Plant Chengjing Water Intake Smart Operation and Transformation Project, which was recently completed and put into operation. The project is independently implemented by Hollysys, and Hollysys is independently controllable, safe and reliable, and deeply developed by the nuclear high-tech project.

The characteristics of Hollysys LK series PLC are introduced in detail The characteristics of Hollysys LK series PLC are introduced in detail

LK is a programmable controller (PLC) product launched by Hollysys for medium and high-performance control fields. It fully integrates the advantages of DCS and PLC, adopts high-performance analog processing technology, miniaturized structural design, open industry standards, and a universal system platform, so that ...

Hollysys PLC - common faults and solutions of CNC machine tool PLC Hollysys PLC - common faults and solutions of CNC machine tool PLC

CNC machine tool PLC (programmable logic controller) has the following common faults in the operation process, and the following corresponding solutions are taken for the faults in the work engineering to make the equipment operate normally. 1. The power grid fluctuates too much, and the PLC does not work It is manifested as no output of the PLC. Check first ...

Hollysys PLC - the top ten comprehensive failure causes of PLC Hollysys PLC - the top ten comprehensive failure causes of PLC

1. Grounding problems The grounding requirements of the PLC system are relatively strict, and it is best to have an independent dedicated grounding system, and it should also be noted that other equipment related to PLC should also be reliably grounded. When multiple circuit grounding points are connected together, unexpected currents can be generated, resulting in logic errors or ...

The difference between Lysys plc - RS232 interface and RS485 interface The difference between Lysys plc - RS232 interface and RS485 interface

1. The physical structure of the interface 1. RS232 interface: One of the computer communication interfaces, usually RS-232 interface in 9 pin (DB-9) or 25 pin (DB-25) form, generally there will be two sets of RS-232 interfaces on personal computers, respectively called COM ...

Hollysys PLC - the use of PLC serial port communication Hollysys PLC - the use of PLC serial port communication

Serial communication is done using 3 wires: (1) ground, (2) sending, and (3) receiving. Since serial communication is asynchronous, ports are capable of sending data on one wire and receiving data on the other. Other threads are used for handshakes, but are not required. Serial communication is the heaviest ...

Hollysys DCS - What are the four contents of DCS spare parts management? Hollysys DCS - What are the four contents of DCS spare parts management?

DCS spare parts In the process of using the DCS control system, its management is more important. The requirements of general DCS spare parts management are summarized in four aspects: storage, inspection, preparation for use, and use. 1. Storage DCS system, spare module storage should meet the requirements ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top