The difference between Delixi soft start and inverter

Create Date: 2024-8-30 12:03:23|Source: Delixi

Features of the soft starter:

The motor can be soft-started, soft-stopped, and soft-stopped.

It can achieve a small impact on the machine-to-power grid.

It is much smaller than the Star-Delta starter and the installation is simple.

                               The difference between Delixi soft start and inverter

Features of the inverter:

The soft starter function is simply available.

It has more maintenance and control functions.

The inverter is used in places where speed regulation and constant pressure change control are required.

Differences:

How do we know which equipment we need for our application? Which equipment you choose depends on how you can handle your needs. If your application requires soft start but not speed control, then a soft starter is the best choice. If speed control is required, an inverter must be used.

In addition, price can be a determining factor in many practical applications. Soft starters are less expensive than frequency converters because they have less control function. If the size of our equipment is the deciding factor, soft starters are usually smaller than most drives.

More on that
Delixi electrical components circuit breaker introduction Delixi electrical components circuit breaker introduction

What is a Circuit Breaker? What is the function of a circuit breaker? How to choose the right circuit breaker in the work? The circuit breaker is what we often call an air switch. Just like a dam that controls the release of water, when the sluice gate is opened, the flow of water is continuous, and when the sluice gate is lowered, it blocks the flow of water. ...

Delixi selects the advantages of the inverter Delixi selects the advantages of the inverter

1. Significant energy-saving effect: up to 20%-45% 2. Optimize electrical equipment: when the motor starts, there is no large current impact, which reduces the load of the transformer 3. Convenient operation: the speed of the motor is directly given according to the size of the air volume, and the accuracy of the air volume is adjusted accurately ...

Delixi circuit breaker accessory function Delixi circuit breaker accessory function

Varieties of circuit breaker accessories It is divided into two categories: in-flight accessories and out-of-flight accessories. The accessories in the machine are the subordinate equipment of the equipment inside the circuit breaker, including four types: shunt tripper, undervoltage tripper, auxiliary switch and alarm switch. Normally the in-flight accessories have to be uncovered with the device, but now ...

Delixi universal circuit breaker CDW9 series maintenance operation Delixi universal circuit breaker CDW9 series maintenance operation

Delixi intelligent all-round circuit breaker CDW9 series, should be checked regularly every year, first open and close and long-distance equipment, successively use a variety of additives, test operation program column, control unit test using a small test suite; Every two years or when the control unit repair target reaches 100, it should be ...

Delixi voltage regulator fault performance and elimination Delixi voltage regulator fault performance and elimination

Regulator problem 1: The regulator cannot be started Reason: Whether the phase sequence of the input power cord has been changed, and the air switch in the machine is not turned on or broken. Repair methods: 1. Swap the two power supply wires arbitrarily or check whether the power supply line is correct; 2. Close or replace the switch. Voltage Regulator ...

Delixi inverter all aspects of the selection of precautions Delixi inverter all aspects of the selection of precautions

The inverter is a device that can control the speed of the motor, and it completes the speed regulation by adjusting the voltage and frequency of the motor. When selecting an inverter, there are several factors to consider, including the power of the motor, the type of load, the operating environment, etc. This article will specifically introduce the selection of frequency converters ...

Delixi circuit breaker mechanism spring design Delixi circuit breaker mechanism spring design

The spring is a widely used component in the circuit breaker mechanism, and the critical spring has a great impact on the function of the circuit breaker. From the perspective of energy, combined with the installation space of the tension spring, the author uses the existing accounting formula of the tension spring to solve the unknown quantity from the known quantity to obtain the required tension spring parameters.

Linear and switching regulator features Linear and switching regulator features

The advantages of linear DC regulator are high stability, small ripple, high reliability, and easy to make a multi-output connected adjustable power supply. The disadvantages are large size, bulkiness, and relatively low power. There are many kinds of this kind of regulated power supply, which can be divided into regulated power supply, stabilized current power supply and ...

Delixi inverter usage Delixi inverter usage

First of all, Delixi inverter has a very high control accuracy. It uses advanced electronic skills and digital control skills, and can control the speed, torque, and current of the motor with a high degree of control. Together, the controller of Delixi inverter also has a high overload capacity and strong ...

Delixi leakage protector tripping causes and solutions Delixi leakage protector tripping causes and solutions

1. The leakage protector does not match the load. This situation mostly occurs when using high-power electrical appliances, and it is generally only necessary to replace the leakage protector that matches the practical needs from scratch. 2. Check whether the switch wiring is correct, ...

The inverter is changed to a servo to consider the key points The inverter is changed to a servo to consider the key points

There are substantial differences between servos and inverters in terms of application intention and function. Which one to choose depends on factors such as operating mode, load conditions, price, etc. Basically, the performance of the servo is superior to that of the inverter. Therefore, when changing from an inverter to a servo, there are generally no operational problems ...

Capacitor identification method of Delixi inverter Capacitor identification method of Delixi inverter

1. The capacitance is generally indicated by "C" plus a number in the circuit (e.g., C25 indicates the capacitance numbered 25). A capacitor is an element composed of two metal films that are placed next to each other and separated by an insulating material. The characteristic of the capacitor is first and foremost the communication through the DC block. The size of the capacitance is ...

Circuit breaker control loop to reduce damage method - Delixi Circuit breaker control loop to reduce damage method - Delixi

1 Anatomy of the causes The various causes of the burning of the control loop components of the unmanned station are analyzed and classified as follows: · When the personnel on duty operate, the precautions are not well grasped or the operation is improper; · The organization does not lock and close the operation when it is not stored in energy, and the auxiliary contact of the switch cabinet ...

Introduction of four-quadrant regulator - Delixi Introduction of four-quadrant regulator - Delixi

A four-quadrant power supply is a power supply capable of absorbing and supplying positive and negative currents and voltages. While a simple voltage converter is capable of generating a fixed output voltage from the input voltage, this feature is not sufficient in some applications. An example is the control of voltage nodes connected to capacitors that ...

The difference between Delixi high-voltage circuit breaker and disconnector The difference between Delixi high-voltage circuit breaker and disconnector

The high-voltage circuit breaker (or high-voltage switch) is the primary power control equipment of the substation, which has arc extinguishing characteristics. When the system is in normal operation, it can intercept and connect the no-load and load currents of lines and various electrical equipment. When there is a problem in the system, it can quickly block the fault with the cooperation of relay maintenance.

Delixi 2P circuit breaker selection introduction Delixi 2P circuit breaker selection introduction

When selecting Delixi 2P circuit breaker, the need is selected according to the additional voltage, additional current and operating environment of the practice circuit. The following are the main series of Delixi 2P circuit breaker and its application scenarios: DZ47s-63 2p Small ...

The principle of circuit breaker jumping, closing and holding circuit - Delixi The principle of circuit breaker jumping, closing and holding circuit - Delixi

During opening and closing operations, the remote opening and closing command is usually a high-level pulse of several hundred milliseconds. In order to prevent the pulse from becoming invalid before the end of the opening and closing operation, and to ensure that the opening and closing operation is completed, a holding circuit is added. Intuitively, it is to avoid tripping and closing, and the exit contact precedes the DL ...

Delixi contactor selection considerations Delixi contactor selection considerations

Electrical safety is not a trivial matter in modern society. Delixi communication contactors are used in homes, public places or commercial buildings. As a power device, its importance is self-evident. If you buy an unsuitable communication contactor, it will appear briefly in the future application process ...

Delixi time control switch adjustment method Delixi time control switch adjustment method

Press the undo function key first, then press and hold the school time function key, then adjust the time and date to the current moment, press the punctual function key again, adjust the time that needs to be closed and open to the specified value, if you need to set multiple groups, then press the punctual function key to set, without multiple groups ...

The 2016 Delixi Electric Construction Industry Summit was successfully held The 2016 Delixi Electric Construction Industry Summit was successfully held

2016 is the first year of the "13th Five-Year Plan", with the adjustment of China's economic structure, the construction profession is also changing. On September 8th, with the theme of "riding the wind and waves, building the future together", the Delixi Electric Construction Career Summit opened in Qingdao, the "International Sailing Capital". The summit ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top