Extended unit address assignment for Omron PLC

Create Date: 2024-8-30 12:03:23|Source: Omron/Omron

2. Extend unit address allocation

The function of the expansion unit is to expand the input and output, and the expansion unit starts from the next channel after the allocation channel of the CPU unit, and assigns the address backwards.

CP1W Expansion Unit

If the CPU unit comes with input occupying 0 channels and 1 channel, and the output occupies 100 channels and 101 channels, the CP1W expansion unit will be connected later:

Its inputs are distributed from 2 channels and backwards, up to a maximum of 16 channels;

The outputs are distributed from 102 channels and then backwards, up to a maximum of 116 channels.

The basic I/O expansion unit of CP1W, according to the number of input and output points, the number of input and output channels allocated is also different, and the bit allocation principle is the same as that of the input and output of the CPU unit, for example, the expansion unit with 12 input and 8 output occupies 1 channel each:

Its input bits occupy bits 00 - bits 11 of the assigned channel, and unused bits 12 - bits 15 will always be cleared and cannot be used as internal auxiliary work bits;

The output bit occupies bits 00 - bit 07 of the assigned channel, and the unused bits 08 - bit 15 can be used as internal auxiliary work bits.

For expansion units such as analog and temperature sensors, the addresses of the input and output channels are allocated according to the number of channels they occupy, for example, the CP1W-MAD11 is assigned 2 input channels and 1 output channel.

CJ series high-performance expansion unit

The address assignment of the CJ series high-performance expansion unit is related to its unit number, which is a hardware switch on the module, and the special I/O unit occupies the address 2000-2959 channels according to the order of arrangement

According to the order of arrangement, the CPU bus unit occupies the address 1500-1899 channel
Extended unit address assignment for Omron PLC

More on that
Instructions for the incorrect operation of Omron micro switches Instructions for the incorrect operation of Omron micro switches

Operation point one During the installation and operation of Omron micro switches, please remember that the direction of action of the operating mechanism of the switch cannot be reversed, otherwise it is easy to cause the fault of the line. Moreover, the position of the switch should meet the requirements of the control circuit and ensure reliable operation. For micro ...

What are the characteristics of Omron 3G3JZ series inverter? What are the characteristics of Omron 3G3JZ series inverter?

1. Standard configuration with RS485 interface, Modbus bus communication function; 2. At 3Hz, it can provide more than 150% torque output and start quickly; 3. The carrier frequency of 2-15KHz is adjustable, which can realize silent drive; 4. Equipped with simple energy-saving function; 5. Controlled ...

Key Features of Omron PLC: Key Features of Omron PLC:

(1) Flexible structure Regardless of the environmental limitations, the network can be built when there is electricity, and the number of access ports can be flexibly expanded, so that the resource utilization rate is high, and it is comparable to WLAN in terms of mobility. (2) High transmission quality, fast speed and stable bandwidth Can be very ...

The exchange activity between Omron and Qingdao Delong was successfully held The exchange activity between Omron and Qingdao Delong was successfully held

Recently, Omron Automation (China) Co., Ltd. (hereinafter referred to as "Omron") and Qingdao Delong Technology Co., Ltd. (hereinafter referred to as "Qingdao Delong") successfully held an exchange activity. Omron Automation (China) Co., Ltd. Fourth Industry Development and Management Division Changzong Town, Qingdao Delong ...

Omron's new E2EW series proximity sensors have the longest sensing range in the world Omron's new E2EW series proximity sensors have the longest sensing range in the world

Hoffman Estates, Illinois, March 24, 2020 – Manufacturers in the automotive industry are trying to capitalize on the current trend toward electric vehicles and low fuel consumption by building lightweight vehicles and favoring aluminum over iron. With the inclusion of both iron and aluminum ...

Omron achieves its goal of increasing its share of the local healthcare market Omron achieves its goal of increasing its share of the local healthcare market

Omron Asia Pacific Ltd. Philippines signed an agreement with Metro Drug Inc., a pharmaceutical sales and distribution company, to expand its distribution network for OMRON Healthcare Philippines' blood pressure monitors, nebulizers, thermometers, body composition monitors, and TENS massagers ...

Introduction to the classification of Omron relay switch contacts Introduction to the classification of Omron relay switch contacts

1.A contacts A contact is a contact in which the two contact terminals are separated (OFF) when the switch is not operated, and closed (ON) when the switch is operated. If you want to start the load by operating the switch, you can use the A contact. A circuit is a circuit that uses a contact without operating the switch (pressing ...

What's going on if Omron PLC can't be installed? What's going on if Omron PLC can't be installed?

1. Open the CX-programmer software; 2. Use rs232 and other communication lines to connect to PLC; 3. Open "PLC" -> "Auto Online"; - >> "Direct Online"; 4. Select "Connection Type" and click "Connection". 5. In the pop-up window, click ...

Causes and solutions for E1 fault codes in Omron electronic sphygmomanometers Causes and solutions for E1 fault codes in Omron electronic sphygmomanometers

The E1 fault code usually appears on the display of the blood pressure monitor and indicates that the inflation pressure is too high or too low. This failure can lead to inaccurate measurement results or even inability to complete the measurement. Solution(s): 1. Check whether the cuff is worn correctly and whether it is properly tightened. ...

Omron CP1 series PLC interrupt classification Omron CP1 series PLC interrupt classification

1. I/O direct interrupt, which is the change of interrupt input from the built-in input unit on the CPU rack (0→1; 1→0). 2. Counting interrupt, the built-in input pulse of the CPU unit of the PLC is counted, and the interrupt is executed when the count reaches the set value. ...

Nine main characteristics of Omron relays Nine main characteristics of Omron relays

1. Extra-small and lightweight Omron relay has developed and manufactured a very small standard, leading the relay industry at home and abroad, and occupying a dominant position in the market. 2. Low driving current The driving current is in the range of 6.5-16 mA, which achieves a low current, and in order to protect the environment, it is eco-efficient.

【Omron industry case】Predictive maintenance of smoke machine in automobile welding workshop 【Omron industry case】Predictive maintenance of smoke machine in automobile welding workshop

Process introduction Automobile welding is the second of the four major processes in vehicle production, which mainly assembles stamped body components into a complete body. In the welding process, spot welding and arc welding of robots are the mainstay, and there will be a station for visual inspection of the welding status in the middle.   Make...

【Omron Industry Case】Application case of robot in cell stack welding 【Omron Industry Case】Application case of robot in cell stack welding

Equipment Overview The stack welding machine is mainly used for the overlap welding of monocrystalline and polycrystalline cells in fully automatic crystalline silicon solar cell modules, and is suitable for series welding of small-size crystalline silicon solar cells.

Causes and solutions for E2 fault codes on Omron electronic sphygmomanometers Causes and solutions for E2 fault codes on Omron electronic sphygmomanometers

The E2 fault code usually appears on the display of the blood pressure monitor and indicates that the inflation pressure is too high or too low. This failure can lead to inaccurate measurement results or even inability to complete the measurement. Solution(s): 1. Check whether the cuff is worn correctly and whether it is properly tightened. ...

FAQs on Omron PLC FAQs on Omron PLC

1.How to install the USB driver of CP1H? The computer is connected to CP1H (powered on) through a USB cable, and the PC will automatically prompt to find the new hardware and prompt to install the driver. 2.The built-in USB port of CP1H can be used ...

What are the common fault phenomena of Omron relays? What are the common fault phenomena of Omron relays?

One. Damage to glass insulators Because the glass insulator of Omron relay is mainly made of metal prongs and glass sintering, it is easy to be damaged in the process of cleaning, overhaul, assembly, etc., such as bending of the pins, falling blocks, cracking, etc., resulting in Omron relays.

Omron's medical predictive electronic thermometer helps efficient epidemic prevention and control Omron's medical predictive electronic thermometer helps efficient epidemic prevention and control

Shanghai, China, July 7, 2022 – Measuring body temperature is an indispensable tool under the normalization of epidemic prevention and control. For hospitals and other places with a high concentration of people, how to improve the efficiency of temperature measurement, so as to do a better job in epidemic prevention in a more targeted manner, is a problem that must be solved. Unique...

Omron switch - 9 tests and methods for switching power supplies Omron switch - 9 tests and methods for switching power supplies

1. Repeated short-circuit test ◆ Test instructions The output of the module is short-circuited in various input and output states, the module should be able to achieve protection or retraction, repeated short-circuits, and after troubleshooting, the module should be able to automatically resume normal operation. ◆ Test Method a ...

The Omron CK3M/CK5M series has four major features to solve the problem of motion control The Omron CK3M/CK5M series has four major features to solve the problem of motion control

How can ultra-precision operations be realized in semiconductor and FPD manufacturing/inspection equipment, such as exposure machines, coating machines, dispensing machines, and wafer inspection equipment? How to control special mechanical mechanisms, such as those with robotic mechanisms, in the manufacture of smart devices? Machining Machine/Stamping Machine ...

How to adjust the Omron laser sensor? How to adjust the Omron laser sensor?

1. Turn on the power supply: Connect the Omron laser sensor to the power supply, and pay attention to the correct wiring. 2. Set parameters: Use the special software of Omron laser sensor to set parameters, including laser power, detection distance, sampling frequency, etc. 3. Aim at the target: Aim the laser sensor at the ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top