Siemens S7-1200 PLC process functions

Create Date: 2024-8-30 12:03:23|Source: Siemens/Siemens

1. S7-1200 CPU motion control
Siemens S7-1200 PLC process functions

S7-1200 Body Motion Control Axis Resources:

In open-loop control mode, the maximum number of pulse axes is 4 and cannot be expanded.

Closed-loop control: The S7-1200 with firmware version V4.1 and above can control up to 8 drives via PROFIdrive or the analog drive interface.

2. S7-1200 CPU high-speed counter function

The S7-1200 body and expansion signal board provide a total of 6 high-speed counters, can be connected to PNP or NPN pulse input signals, and supports incremental rotary encoders.

The S7-1200 high-speed counter supports the following 4 operating modes:

Single-phase counting, direction controlled internally or externally

Two phases

A/B quadrature counters

A/B quadrature counter quadruple

More on that
Siemens joins hands with Lee Kum Kee to build a benchmark factory for digitalization and decarbonization Siemens joins hands with Lee Kum Kee to build a benchmark factory for digitalization and decarbonization

Based on a deep understanding of the pain points and needs of the whole industrial chain of the condiment industry, Siemens provides Lee Kum Kee with one-stop solutions from project consulting, digital products to the implementation of engineering projects, helping it build a digital, standardized, transparent and low-carbon benchmark factory.

SIMATIC S7-1200 compact CPU SIMATIC S7-1200 compact CPU

Installation 1. Remove the backplane bus cover 2. Insert the SM onto the standard mounting rail 3. Push the SM to the adjacent module 4. Lock the standard rail mounting clip 5. Push the latch used to connect the bus connector to the left so that the bus pin is connected to the adjacent module ...

Daimler Trucks and Siemens have partnered to build a digital integrated engineering platform Daimler Trucks and Siemens have partnered to build a digital integrated engineering platform

Siemens Digital Industries and Daimler Trucks have announced a new collaboration to leverage Siemens Xcelerator industrial software and services portfolio to build an advanced digital engineering pipeline. The channel will enable Daimler Trucks to explore the innovations of commercial vehicles.

Siemens 3RW44 soft start press emergency start why not Siemens 3RW44 soft start press emergency start why not

The 3RW44 has an emergency start function, but why does the soft start not start when the emergency start button is closed? Emergency start refers to the unevenness of the motor; thermal model overload; Open circuit of temperature sensor; Short circuit of the temperature sensor; The temperature sensor is overloaded; Exceeding the maximum starting time; Surpass...

How to erase the password using a memory card How to erase the password using a memory card

If the customer has forgotten the password of the S7-1200 that was previously set, the program and password inside the S7-1200 cannot be erased through "Factory Reset", and the only way to erase the password is to use a memory card. The detailed steps are as follows: Power off the S7-1200 device Insert a ...

Siemens' path to the world's first native digital factory Siemens' path to the world's first native digital factory

Siemens CNC (Nanjing) Co., Ltd. (SNC) officially opened its new factory. This is Siemens' first fully integrated native digital factory in the world, and it is also an excellent "answer sheet" written by Siemens for the "professional examination" of building a digital factory. 1996 ...

Some reasons why Siemens motor motors heat up Some reasons why Siemens motor motors heat up

The motor is an energy conversion mechanism, and some losses will inevitably occur in the process of energy conversion, and most of these losses will be turned into heat dissipation, which will increase the temperature of the motor. Excessive temperatures can lead to a shortened life of certain motor components, which can eventually lead to failures. Motor...

The Mendix low-code development contest is now open The Mendix low-code development contest is now open

Siemens will use Mendix, the industry-leading low-code development channel under Siemens, to meet the practical business needs of enterprises, combine several general scenarios, and deepen the learning of Mendix low-code channels, so that we can understand the essence of the product, stimulate innovation ideas, and open up the road to innovation. ...

Siemens S7-1200 CPU motion control and high-speed counter function Siemens S7-1200 CPU motion control and high-speed counter function

1. S7-1200 CPU motion control S7-1200 Body Motion Control Axis Resources: In open-loop control mode, the maximum number of pulse axes is 4 and cannot be expanded. In closed-loop control mode: S7-1200 with firmware version V4.1 and above can be used in ...

Siemens actively supports Shanghai and the Yangtze River Delta Siemens actively supports Shanghai and the Yangtze River Delta

Shanghai, the historic "Pearl of the Orient" is famous for its prosperity, openness and fashion, and is the engine of China's economic growth. Since 1904, when the first permanent office in China was established in Shanghai, Siemens has been deeply rooted in this land of innovation and entrepreneurship.

Siemens has built a digital production line for Nissan's all-electric crossover SUV Ariya Siemens has built a digital production line for Nissan's all-electric crossover SUV Ariya

Siemens recently announced a partnership with Nissan to build a digital production line for its new all-electric crossover SUV Ariya at Nissan's plant in Tochigi Prefecture, Japan. The partnership has been around for a long time, and Nissan has been using the Siemens Digital Industry Software portfolio for its own planning and ...

Features of the Siemens S7-1200 memory card Features of the Siemens S7-1200 memory card

The memory card used by the S7-1200 CPU is an SD card, which can store user project files and has the following three functions: As a mount store for the CPU, user project files can be stored only on the card, without project files in the CPU, they cannot run without the memory card. ...

Siemens S7-1200 CPU FAQ solved Siemens S7-1200 CPU FAQ solved

Can the 5 VDC power supply provided by the CPU be scaled with an external power supply? A: No, select the appropriate CPU based on the template 5 VDC power usage. Can I use an external power supply when the 24 VDC power supply provided by the CPU is not enough? A: Yes, ...

Siemens acquires Brightly Software to accelerate its development in the field of smart buildings Siemens acquires Brightly Software to accelerate its development in the field of smart buildings

Siemens Intelligent Infrastructure recently announced that it has signed an agreement to acquire Brightly Software, a SaaS provider of asset and protection management solutions in United States. The acquisition will strengthen Siemens Intelligent Infrastructure's position in the building and infrastructure software segment. Harvest...

New features of Siemens SIMATIC S7-1200 PLC V2.0 New features of Siemens SIMATIC S7-1200 PLC V2.0

In addition to the existing product features, SIMATIC S7-1200 V2.0 adds the following mechanisms and functions: Integrated PROFINET-IO controller interface with integrated PROFINET interface Profibus DP master (via communication module) Profibus DP ...

Siemens S7-1200 series frequently asked questions about formulation functions Siemens S7-1200 series frequently asked questions about formulation functions

1.Do all CPUs in the S7-1200 series support recipe functions? The CPU version of the S7-1200 is V4.0 or later, and recipe function instructions are supported. HOWEVER, THE FUNCTION OF THE FORMULA IN A BROAD SENSE, FROM THE TIA PORTAL V11 SP2, S7-1200 V2.0 FIRMWARE VERSION ...

Siemens' Sinumerik ONE technology features new technologies to help customers operate Siemens' Sinumerik ONE technology features new technologies to help customers operate

Siemens is further expanding the capabilities of the Sinumerik ONE "digital native" CNC system. For this new generation of CNC system launched in 2019, Siemens has made innovations in both software and hardware this year. With Sinumerik V6.20 software, Sinumerik ...

Siemens has released version 4.0 of the web-based SIMATIC PCS neo control system Siemens has released version 4.0 of the web-based SIMATIC PCS neo control system

Process industrial companies are faced with multiple challenges: how to accelerate digitalization, achieve sustainable development, and how to deal with the shortage of skilled personnel. At Siemens, we believe that plant managers can only cope with these challenges and prepare for the future with a highly sensitive process control system. In this cloth ...

How to use the data block of the Siemens S7-200 SMART How to use the data block of the Siemens S7-200 SMART

How to use the data block of Siemens S7-200 SMART. Before explaining the use of data blocks, let's take a look at what data blocks are: data blocks are used to assign initial values to the V store, also called the variable store; Ability to assign data values to bytes, words, or two words.   Divide the data in a chunk ...

Siemens Xcelerator accelerates the digital transformation of the machine tool industry Siemens Xcelerator accelerates the digital transformation of the machine tool industry

Siemens unveiled the World Metalworking Exhibition (AMB) 2022 with the theme of "Accelerating Progress, Digital Empowerment for Sustainable Development", showing how to unleash the huge potential of machine tool optimization through the continuous analysis of production data. Siemens Xcelerator Open Digital Commerce Channel, ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top