Complete set of electrical maintenance knowledge:
1. Low-voltage distribution cabinet
1. Regularly check whether there are traces of pest activity in each cabinet, and carry out trapping regularly.
2. Check whether the warning signs and maintenance signs are placed correctly.
3. Check whether the emergency tools and lamps are complete and normal, and whether the crank handle and fuse handle are complete.
4. Check whether the cable joint has heat discoloration (generally silver) and whether the grounding wire is corroded (whether the soldering point is normal).
5. Check whether the capacitor shell in the capacitor cabinet is good, whether there is leakage and expansion, and whether the indicator light is good.
6. Check the contact of the grounding wire of each capacitor shell.
7. Do a good job of cleaning and dust removal of each cabinet.
8. Check the working condition of the fans of each cabinet.
Second, the first level of maintenance
1. Check whether the busbar and its lower lead are firm.
2. Check whether the wiring of the secondary circuit is firm, whether the fuse is intact and the shaking test of insulation resistance.
3. Inspection of the capacitor cabinet: when the air switch is disconnected without capacitance, the action test of the capacitor controller should be carried out, and the over-voltage protection, under-current protection and switching threshold should be adjusted.
4. The indicators should be in good condition, and the circuit breaker leakage switch, thermal relay, intermittent relay, multi-function meter, etc. should be checked and adjusted.
5. Check whether the instruction lamp is normal, whether the switch position of the controller is normal, the operation should be normal, and whether the mechanical interlocking part of manual debugging is reliable.
6. Check whether the fasteners of each soft starter and inverter can be loose.
3. Secondary maintenance
1. Check whether the drawer switch is flexible to push in or out, its mechanical locking is reliable, and whether the contactor contact is good.
2. Check whether the elastic force of each knife edge in the circuit breaker is normal and whether the arc extinguishing device is in good condition.
3. Check whether the wiring nuts of each cable head are tightened.
4. After disconnecting the main switch of the power receiving cabinet and the contact cabinet, shake out or shake out with a special crank should be flexible, the secondary terminals such as the transformer are in good contact and fastened without loosening, and the primary and secondary lines are free of mildew.
Fourth, the daily maintenance of the incoming switch
1. Check the cleanliness of the device, use a clean, dry cloth to wipe off any dust and oil stains, and if possible, use a non-corrosive detergent.
2. Check whether the nameplate of the equipment is in good condition. Use a clean dry cloth to clean these nameplates on the half corner.
3. Wipe off dust, mold and oxides, and also clean the inside of the fixed part of the draw-out circuit breaker. Make sure there are no foreign objects in the circuit breaker room.
4. Use a clean and dry cloth to remove dust or dirt from the edge and busbar of the circuit breaker.
5. Confirm that the bolts used for terminal connections are properly tightened and that there are no signs of localized overheating on the terminals. Heat can be identified by looking at the color of the contact parts, which are usually silvery-white.
7. Check that the cables on the sliding contacts or terminal strips are secure
How it should be maintained on a daily basis
1. Do a good job of insulation
Usually the temperature range of high and low voltage complete sets of distribution cabinets is between -10 °C and 45 °C, if the ambient temperature is too high, the conductivity of metal parts will be lower, and the resistivity will become larger, and the oxidation will gradually accelerate, and the dielectric strength of insulating parts will also decrease. Of course, too cold environment will also cause large internal stress in equipment components, thereby destroying the reliability of insulators. Therefore, it is necessary to add some reinforced insulation electrical appliances and insulation protection measures according to the situation, and the surrounding environment requires no fire source, no pollution, and no corrosive chemicals.
2. Do a good job of dust prevention regularly
In order to eliminate the impact of dust accumulation on insulation performance, the dust in the equipment should also be cleaned regularly with a brush, and the circuit breaker that is often operated in daily life should be regularly checked for the loosening of the fixing screws and do a good job of fastening.
3. The internal wiring of the high and low voltage complete sets of distribution cabinets must be reasonable
Sometimes because of the production needs, need to connect the temporary power supply from the switch cabinet for the use of high-voltage equipment, in strict accordance with the electrical safety management regulations, the use of good insulation performance of the wire, its safety should be able to fully meet the needs of the electrical load, so that electrical professionals to operate, the wiring is required to be smooth and not knotted, there is no mutual entanglement between the wires, and reliable grounding work is done. When the temporary power supply is not needed, the newly added power supply facilities need to be dismantled and cleaned up in time.
|
More on that
|
Rittal cabinet - knowledge quiz of high and low voltage distribution cabinet (1-10)
1. What is TT, IN, IT system?
A: The TT method refers to a protection system that directly grounds the metal shell of electrical equipment, which is called a protective grounding system, also known as a TT system. The TN method is a protection system that connects the metal shell of the electrical equipment with the working neutral line, called ...
|
|
Rittal's enclosure – seven common faults in the distribution cabinet and their failure analysis
1. The circuit breaker cannot be closed
Causes:
1. The undervoltage coil does not work (the voltage is normal). Solution: Replace the undervoltage coil.
2. Press the closing button, and the closing coil will not work when it is powered up. Solution: Replace the undervoltage coil.
3. Cooperation...
|
|
Rittal cabinet - knowledge quiz of high and low voltage distribution cabinet (41-50)
41. Can power lines be divided into according to the erection method?
A: Overhead power lines and cable lines.
42 What is a protective relay?
Answer: It can reflect the failure or abnormal operation of electrical equipment in the power system, and act on the switch to trip or send out a signal ...
|
|
Rittal Cables – the principle of selection of power cables
1. Selection of wire and cable models
When selecting wires and cables, it is necessary to consider the use, laying conditions and safety; For example, depending on the application, power cables, overhead insulated cables, control cables, etc. can be selected
According to the different laying conditions, the general plastic insulated cable can be selected ...
|
|
Rittal cabinet air conditioner fault code
The fault codes for Rittal cabinet air conditioners are: F1, F2, F3, FF, EH, EP, EL, SF, HC.
F1, F2, F3 represent improper use or failure of internal components;
FF stands for Regulation Circuit Fault;
EH stands for High Temperature Fault;
EP stands for Actuator Failure; ...
|
|
Rittal cables – classified according to the purpose of the cable and the environment in which it will be used
1. DC cable
(1) Tandem cables between components.
(2) Parallel cables between strings and between strings and DC distribution boxes (combiner boxes).
(3) The cable between the DC distribution box and the inverter.
The above cables are all DC cables, outdoor laying ...
|
|
Rittal innovates the Ri4Power top-of-the-line distribution cabinet system
Ri4Power satisfies four specifications of the system
Rittal Ri4Power has developed this concept as a complete system solution for the safe and fast installation of low-voltage switchgear for machines, systems and buildings. Rittal Ri4Power It is a device that covers high-current power distribution ...
|
|
Alarm code causes and diagnostic methods for Rittal cabinet air conditioners
Alarm code: A01
System message: Open the cabinet door
The cause of the Rittal air conditioner: the opening and closing of the door is not in the correct position
Diagnostic method: Check the changing position of the door and, if necessary, the connection status
Alarm code: A02
System message: The temperature in the cabinet is too high
...
|
|
Rittal Nonwovens filter mats product description
Product Introduction
Product name: Rittal Rittal
Product Type: Rittal Non Woven Filter Mats
Product Model: 3172.105
Spare filter mats for top-mounted fans, filter fans or thermoelectric coolers to protect control cabinet components from dirt, ash ...
|
|
Common faults and solutions for Rittal cabinet air conditioners
If the indoor temperature is higher than the outdoor one, or the indoor temperature is higher than the set temperature, the air conditioner will not start;
Solution: Test the temperature comparison between indoor and outdoor to check whether the indoor temperature is too high.
The voltage of the air conditioner is unstable, and the compressor cannot be started normally.
|
|
Rittal cabinets – maintenance methods for motor control cabinets
1. Disconnect the power supply, check whether the rack of the control cabinet has reliable grounding, and make the grounding resistance not greater than 4Ω.
2. There are voltages of different properties on the control cabinet (DC 110V; Communication single-phase 220V; Three-phase communication), the circuit must be distinguished during maintenance to avoid short-circuit accidents.
|
|
Rittal for AE model 2733.000
Rittal for AE
Product model 2733.000
Retrofit on AE in place of a door, or on a sufficiently large flat surface.
Product Description: For retrofitting on AE instead of doors and flat surfaces
Material: Frame: Aluminum, by natural aluminium anode
|
|
What are the application areas of Rittal cabinets – cabinet air conditioners?
Indoor unit: suitable for all kinds of control boxes, distribution boxes and electrical cabinets in machinery, electric power, chemical industry, textile machinery, automation equipment, instrumentation and other industries with high requirements for temperature and humidity. It can also be used to regulate temperature and humidity in small spaces.
Outdoor unit: suitable for outdoor general base station, outdoor ...
|
|
What is the daily maintenance method of the air conditioner? - Rittal air conditioning
1. Filter maintenance of the indoor unit: The filter screen of the indoor unit generally needs to be replaced once every two months. It is not recommended to continue to use it after rinsing, because the rinsed filter is easy to stick, so that ventilation and ventilation are not smooth, and air circulation is affected. So if it's a one-off, direct replacement, not ...
|
|
The Rittal SE 8 system cabinet shows you what efficiency looks like
SE 8 system cabinet
Lightweight, yet still strong
Industry applications are becoming increasingly complex, and there is a demand for low-complexity cabinet systems for efficient assembly in all industry applications. To meet the needs of the market, Rittal has launched the new SE8 freestanding enclosure.
...
|
|
Analysis of the fault codes of the Rittal cabinet air conditioner
1. A01 system message: open the cabinet door Rittal air conditioner Cause: the position of the door opening and closing is incorrect;
2. A02 system message: the temperature in the cabinet is too high: the refrigeration capacity is too low or small;
3. A03 System Message: Filter Monitoring Cause: Dirty Filter Diagnosis ...
|
|
Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets
Which electrical equipment must be grounded or zeroed?
Answer: (1) The base and shell of generators, transformers, motors, high and low voltage electrical appliances and lighting appliances; (2) the secondary coil of the transformer; (3) the framework of the switchboard and the control panel; (4) Transmission device of electric equipment ...
|
|
A detailed assortment of Rittal products
Rittal's products are: Rittal control cabinets: small cabinets (polycarbonate cabinets PK, junction boxes KL, compact control boxes EB, bus cabinets BG), compact control cabinets, plastic control cabinets KS, cabinet systems (subdivided into TS 8/SE 8 family), parallel cabinet systems...
|
|
Rittal Cabinet - Knowledge Q&A of High and Low Voltage Distribution Cabinet (21-30)
21. What does the workplace have to meet for high-voltage electrical appliances?
Answer: A. Rated voltage, B. Maximum working voltage, C. Rated current, D. Rated short-circuit interrupting current, E. Short-time withstand current and peak withstand current.
22. What are the basic requirements for a high-voltage circuit breaker?
Answer: A work ...
|
|
The Rittal plastic handle replaces the standard lock with or without a secure semi-circular cylinder
Product Model 2485.100
Replace standard locks with or without a secure semicircular cylinder.
Type::C
Color: RAL 9011
A note on the order number: Not suitable for AE 1018.600
Lock: Cylinder: No safety cylindrical cylinder
...
|
|