Introduction to the installation method of Siemens fuse
(1) Before installation, check whether the additional voltage of the Siemens fuse is greater than or equal to the additional voltage of the line. Whether the additional breaking capacity of the fuse is greater than the expected short-circuit current in the line, and whether the additional current of the melt is less than or equal to the additional current of the fuse support.
(2) West ...
|
|
Siemens, Xcelerator, and Omniverse create an industrial metaverse
Siemens Xcelerator and NVIDIA Omniverse combine virtual and hands-on international simulation, data profiling, and artificial intelligence to provide new insights and benefits for product planning and production.
The collaboration between the two sides will bring Nvidia's Omniverse real-time, ...
|
|
Frequently Asked Questions for Siemens S7-1200 Motion Control
What is the difference between absolute and relative positioning?
Answer: Relative positioning refers to moving a certain distance in the positive or negative direction on the basis of the current orientation of the axis; Affirmative positioning means that when the axis establishes a positive coordinate system, each azimuth of the axis has a fixed coordinate, regardless of the azimuth value of the axis at that time.
|
|
Siemens and Guangdong Shicheng work together to build a native digital factory
The industrial sector is in the midst of a digital revolution, and Siemens is committed to helping our customers transform into truly digital enterprises and make them more competitive on the road to the industrial future.
Founded in 2003, Guangdong Shicheng Plastic Machinery Co., Ltd. is a collection of scientific research and development.
|
|
Siemens loads the item to a memory card in transfer mode
Mount items to a memory card in transfer mode
Step 1: Follow the above method to set the memory card to "Transfer Card" mode. Customers are advised to clear all files from the memory card before doing this.
Step 2: Set the boot state of the CPU: In the "Project ...
|
|
Siemens S7-1200 PLC power requirements and calculations
The S7-1200 CPU offers 5 VDC and 24 VDC power supplies:
When there is an expansion template, the CPU provides it with 5 VDC power over the I/O bus, and the sum of the 5 VDC power consumption of all expansion modules cannot exceed the power rating provided by the CPU. If it's not enough, you can't go outside ...
|
|
The Siemens S7-200SMART is a countermeasure for handling fast response signals
Some of the advanced features of the S7-200SMART can be used individually or in combination:
Use the CPU's built-in high-speed counter and high-speed pulse generator to process the sequence pulse signal;
Hardware interrupt function at some CPU digital input points, processed in the interrupt service program, ...
|
|
The Siemens 3RM11/3RM13 motor starters have two different protection functions
The 3RM11/3RM13 motor starters include two different protection functions.
One protection function is a safety application, and the other is an explosion protection application (ATEX).
1. Functional Safety:
Here, the purpose of protection is to identify and control dangerous conditions. In the safe ...
|
|
The Siemens Production Machinery Technology and Application Center was officially launched in Beijing
The Siemens Production Machinery Technology & Usage Competence Center (TAC) was officially launched today in Beijing. The center not only comprehensively demonstrates Siemens' innovative products and cutting-edge technology use, but also provides a set of innovative development, virtual simulation and scheme verification of machinery and equipment for the vast number of machinery manufacturing enterprises.
|
|
The new factory of Siemens CNC (Nanjing) Co., Ltd. (SNC) was officially put into operation
The new factory of Siemens CNC (Nanjing) Co., Ltd. (SNC) was officially put into operation. As the world's first native digital factory of Siemens, SNC's new factory fully demonstrates the real value of Siemens' advanced digital corporate philosophy and skills. Even before it was built in the field, Siemens was using it in all directions...
|
|
Siemens Intelligent Power Distribution won the "Samsung Supplier" of the 2022 Supplier Composite Index SCI
On July 5th, the 8th Global Shenzhen Business Conference and Mining and Construction Consortium Conference was successfully held in Shenzhen, and the results of the 2022 Supplier Induction Index SCI evaluation were released on the spot.
|
|
Update the firmware version of your S7-1200 CPU with a 24M memory card
1. Use your computer to erase the contents of the memory card through a card reader. Note: Do not format the memory card!
2. Download the latest version of the firmware file from the official website of Siemens. After downloading and unzipping, you can get a "S7_JOB.SYS" file and a "FWUOPDATE. S7S ...
|
|
Siemens joins hands with Sanning: Ensuring safe production and contributing to green chemical industry
The industrial site of Sanning Chemical Co., Ltd. (Sanning Chemical) is simply unattended, and the production meets various national environmental protection goals, and the park is as beautiful as a garden, and the company's vision is written on the tower, "to build a beautiful chemical industry, to build a century-old Sanning".
Back in 2017, ...
|
|
Siemens joins hands with Chery to stimulate new momentum for the development of the automotive industry
Chery is a leading manufacturer of self-owned brand cars in China and one of the largest passenger car exporters in China. In recent years, Chery has actively practiced the core strategy of "Digital Chery", and built an intelligent and connected "factory of the future" in Wuhu, Anhui Province, accelerating the transformation from "traditional cars" to "smart cars".
|
|
Siemens and Tsinghua Suzhou Institute for Environmental Innovation jointly released a white paper titled "Green Star: A Pioneer in China's Low-Carbon Parks".
Siemens and Tsinghua Suzhou Institute for Environmental Innovation today jointly released a white paper titled "Green Star: A Pioneer in the Low-Carbon Path of China's Parks", which aims to evaluate the low-carbon development performance of parks with a scientific index system and contribute to the low-carbon transformation of China's parks. The white paper examines the low-carbon development of 32 homes...
|
|
Siemens S7-1200 CPU motion control and high-speed counter function
1. S7-1200 CPU motion control
S7-1200 Body Motion Control Axis Resources:
In open-loop control mode, the maximum number of pulse axes is 4 and cannot be expanded.
In closed-loop control mode: S7-1200 with firmware version V4.1 and above can be used in ...
|
|
Siemens released a white paper on zero-carbon smart parks
Siemens today officially released the "Siemens China Zero Carbon Smart Park White Paper" (hereinafter referred to as the white paper), which analyzes and proposes the definition and architecture of zero carbon smart parks, the core pain points and entry points of various parks, and shares the current situation and trend of carbon peak and carbon neutrality in China and China.
|
|
Advantages of the SINAMICS G120 modular frequency inverter from Siemens
1. The modular design creates a high degree of flexibility and can be adapted to the future requirements of the drive concept
The control unit can be replaced in the energized state (hot-swappable).
Plug-in terminals are used
The equipment is easy to replace and easy to maintain
2. Integrated security features, so ...
|
|
Three classifications of the internal storage area of the Siemens S7-1200
The internal storage of the S7-1200 is divided into three types: working storage area, loading storage area, and maintenance storage area.
Loading storage area:
is a non-volatile store. Used to store user project files (user programs, data, and configuration).
If you don't use a memory card, use ...
|
|
Siemens PLC communication mode
1. Serial communication
Siemens PLC supports serial port communication, in S7-200 and S7-200Smart, all directly integrate serial ports, but from S7-1200 to S7-1500, gradually canceled, if required, can be increased by the method of expansion module, the reason for this phenomenon ...
|