The wiring of the load cell – we are responsible

Create Date: 2024-8-30 12:03:23|Source: P+F/Double Blessing

Load cells can be wired in two different input and output ways:

One is the four-wire connection method

The load cell of the four-wire connection method has no special requirements for the secondary instrument panel, and the time and time of use are very convenient, but when the cable is long, it is very simple to be affected by factors such as the working temperature;

                              The wiring of the load cell – we are responsible

The other is the six-wire connection method

The load cell rules of the six-wire system connection method and the secondary instrument panel assigned to the use have a reverberation input socket, and the use standard has certain limitations, but it is not easy to be determined by the working temperature and other factors, and has certain benefits in high-precision and accurate measurement and long-distance accurate measurement.

How to wire in two ways:

It is the first to clarify the switching power supply positive, switching power supply negative, positive response, negative response, positive data signal and negative data signal of the sensor socket on the display screen. If it is a 6-wire transmitter, the two groups of wires with very small sensor resistors are the switching power supply and the positive response; After receiving the display screen, the sensor is loaded, and the current value (millivolts) of the other two wires is accurately measured, and the display data signal is positive, and the display data signal is negative; If it is a four-wire value, the switching power supply of the display screen must be positively wired with the repercussions, the negative and negative repercussions of the switching power supply, and the four wires of the sensor should be measured with a multimeter, and the two with larger resistance values between them are the switching power supplies, and the other two are data signals;

According to the origin of the sensor, we can distinguish by the color of the wire, we are generally red for the switching power supply positive, black for the switching power supply negative, yellow for the data signal positive, white for the data signal negative.

More on that
Engineered Vibration Sensor Test Methods – Blessing Engineered Vibration Sensor Test Methods – Blessing

In the field of engineering oscillation testing, there are various test methods and methods, but they can be divided into three categories according to the measurement methods of various parameters and the physical properties of the measurement process. 1. Mechanical quizzes Will the works oscillate ...

Points to note for encoder installation Points to note for encoder installation

1. Each electrical interface has its own characteristics, but also has different baud rate and transmission interval, which can be selected according to the specific application environment of the site, and the actual transmission interval is very related to the transmission rate, encoder and communication cable installation disturbance environment, grounding, cable material selection, etc. ...

Classification of the movement mode of the displacement sensor Classification of the movement mode of the displacement sensor

The displacement sensor has no sliding contacts, is not affected by non-metallic elements such as dust during operation, has low power consumption, and has a long service life, so it can be used in various bad conditions. Displacement sensors are mainly used to intelligently control the analog quantity of automation equipment production lines. The displacement sensor selects laser three...

The role and classification of safety barriers The role and classification of safety barriers

In electrical intrinsic safety explosion-proof, we generally divide the workplace into explosion-proof areas and non-explosion-proof areas. There is the transmission of electrical energy between the explosion-proof area and the non-explosion-proof area, for example, the switches, buttons, sensors, etc. in the explosion-proof area are connected to the PLC placed in the electrical cabinet in the non-explosion-proof area through wires.

Anti-jamming technology for sensors – we are blessed Anti-jamming technology for sensors – we are blessed

1. Shielding skills Containers are made from metal materials. Wrapping circuits that require maintenance between them can effectively prevent the disturbance of electric or magnetic fields, which is called shielding. Shielding can be divided into electrostatic shielding, electromagnetic shielding and low-frequency magnetic shielding. 2. Electrostatic shielding ...

Introducing the sensor Introducing the sensor

From leveling cranes and monitoring the inclination of front-end loaders to operating elevators, inclination and acceleration sensors can be used in a variety of ways. These sensors are guaranteed to measure even in harsh conditions. Thanks to the innovative split unit concept, the F99 series ...

Fault detection of load cells and corresponding replacement – we are blessed Fault detection of load cells and corresponding replacement – we are blessed

1. Fault judgment When the electronic scale presents the following phenomena, it is necessary to see whether the load cell presents a problem. 1) If the electronic scale does not show zero, the display screen continues to shine or show zero in the future, and the weighing number does not appear when weighing. 2) Electric ...

How to use different types of tension and compression sensors – we are blessed with blessings How to use different types of tension and compression sensors – we are blessed with blessings

Tension and compression sensors are one of the load cells. A device that converts physical data signals into accurately measured electronic signal outputs. It is widely used in industrial production weighing equipment, platform scales, electronic scales, hook scales, batching scales and other dynamometers. But different types of tension and compression sensors are used differently, and now ...

Pressure sensors are prone to malfunction – we are blessed Pressure sensors are prone to malfunction – we are blessed

The first is pressure, and the transmitter can't afford to lose it. In this case, see if the pressure connector is leaking or clogged, if you admit that it is not, look at the wiring method and see if the power supply is normal, simple pressure to confirm if the output has changed, or if there is an output at the zero point of the sensor ...

Illustrate the dynamic characteristics and linearity of our sensors Illustrate the dynamic characteristics and linearity of our sensors

The dynamic characteristics of a sensor refer to the characteristics of the output of the sensor when the input changes. In practice, the dynamic characteristics of the sensor are often indicated by its echo to some normative input signals, because the echo of the sensor to the normative input signal is easy to obtain by experimental methods, ...

Fault detection of pressure sensors – we are blessed Fault detection of pressure sensors – we are blessed

First, the first component blocking may be the wrong way of the device, the pressure point is unreasonable, so we often emphasize that the device must be the correct device, once the installation is wrong, maybe the installation is not good, it will bury endless hidden dangers for the back. What are the primary components? Orifice plates, remote transmission measuring joints, etc.

Wiring of weighing strain gauge tension and compression sensors – we are in control Wiring of weighing strain gauge tension and compression sensors – we are in control

Strain gauge tension and compression load cells are available in two different input and output wiring methods: The first is the four-wire connection method. The load cell of the four-wire connection method has no special requirements for the secondary instrument panel, and it is very convenient to use, but when the cable is long, it is easy to be shaken by the operating temperature.

Problems and analysis of P+F encoders in use Problems and analysis of P+F encoders in use

Analysis of the causes of the problems encountered by P+F in the use of encoders: 1. Grating pollution This will reduce the signal output amplitude, and the oil must be quietly wiped off with absorbent cotton dipped in anhydrous alcohol. 2. Encoder connection cable ...

The principle of installation of safety barriers The principle of installation of safety barriers

1. The safety barrier should be installed in a safe place, and the environmental conditions should meet the requirements of the "application conditions" in the "Safety Barrier Selection Sample". 2. The connecting wires of the intrinsically safe end (blue end) and non-intrinsically safe end circuits of the barrier safety barrier are in the sink ...

Precautions for installation during the use of encoders Precautions for installation during the use of encoders

First of all, the following points should be paid attention to when wiring the encoder: 1. It is necessary to use a metal cable bracket and ensure that the bracket connection is connected to the ground; 2. The cable should be arranged as close to the metal parts as possible, such as control cabinet panels, beams and metal rails, etc.

Motor control requires encoders for reasons – and we are blessed Motor control requires encoders for reasons – and we are blessed

The motor control loop is mainly composed of a motor, a controller, and a directional response interface. The motor rolls the rotating shaft and drives the robotic arm to move. The motor manipulator controls when the motor applies force, stops, or continues to roll. The azimuth interface in the loop supplies the rotational speed and azimuth information to the controller ...

Test Methods for Torque Transducers – Beggarbless Test Methods for Torque Transducers – Beggarbless

In recent years, the use of torque sensors has gradually increased, it can convert physical changes into accurate electrical signals, so what methods can torque sensors go through? The proven test method of torque sensors is ...

Introduction and installation matters of the safety barrier Introduction and installation matters of the safety barrier

The safety barrier, also known as the safety factor meter, is an important part of the intrinsic safety system.   There are two main types of barriers: P+F Zener barriers and P+f isolated barriers. The core elements of a double Forgina barrier are a diode, a current-limiting resistor and a fast fuse. ...

Q&A on ultrasonic sensor technology Q&A on ultrasonic sensor technology

Q1: How does the ultrasonic sensor work? Ultrasonic sensors are used to measure the detection function of emitting high-frequency sound pulses that are inaudible to the human ear, which are dispersed in the air into a conical shape and reflected back as soon as they hit an object. Ultrasonic ...

Photoelectric switches for sensors Photoelectric switches for sensors

Photoelectric switches are what we generally call sensors. The definition of the sensor under the national standard GB7665-87 is: the equipment or device that can feel the specified measured parts and convert them into usable signals in accordance with certain rules, generally composed of sensitive elements and conversion elements. ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383