In the manufacturing industry, there are a large number of open-loop sequential control based on switching quantities, which carries out sequential action numbers according to logical conditions and operates in chronological order; In addition, there is the control of chain protection actions according to the logical relationship that is not related to the sequence and timing; As well as a large number of switching, pulse, timing, counter, analog over-limit alarm and other state quantity-discrete data acquisition and monitoring. Due to these requirements for control and monitoring, PLCs have developed into products that mainly replace relay circuits and perform sequential control. PLC manufacturers have gradually increased various communication interfaces on the original CPU template, and fieldbus technology and Ethernet technology have also developed synchronously, making the application range of PLC more and more extensive. PLC has the advantages of stability and reliability, low price, complete functions, flexible and convenient application, convenient operation and maintenance, which is the fundamental reason why it can occupy the market for a long time.
The hardware of the PLC controller itself adopts a building block structure, with a motherboard, a digital I/O template, an analog I/O template, a special positioning template, a barcode recognition template and other modules, and the user can use the method of expanding on the motherboard or using the bus technology to equip a remote I/O slave to get the desired number of I/O according to the need.
While the PLC realizes a variety of I/O control, it also has the ability to output analog voltage and digital pulses, so that it can control a variety of servo motors, stepper motors, frequency conversion motors, etc. that can receive these signals, plus the man-machine interface support of the touch screen, PLC can meet your needs at any level in process control.
|
More on that
|
Megmeet inverter - heating noise harmonic problems in inverter applications and countermeasures
First, some problems in the application of frequency converter
1.1
Harmonic problems
The devices that play a switching role in the main circuit of the inverter must generate harmonics in the process of turning on and off the circuit. The lower harmonics usually have a greater impact on the motor load, causing torque ripple; And the higher ...
|
|
Common faults and solutions of Megmeet inverter
Fault one
Fault phenomenon: the leakage protection switch trips, the inverter is energized or the equipment leakage protection switch is operated during operation
Solution: 1. When the inverter drives the motor, the leakage value is larger than that of the non-inverter system, and the leakage protection value of the leakage protection switch is required to be more than 150mA, ...
|
|
Megmeet Inverter - Summary of Common Faults of High Voltage Inverter (21-32)
21。 The unit is overheating
The radiator in the unit is equipped with a temperature switch (normally closed point), and when the temperature exceeds 85°C, the normally closed point of the temperature relay is disconnected, and the unit is overheated and faulty.
Check whether the cabinet top fan is working properly, whether the unit cabinet fan switch is tripped, and whether the filter screen is blocked.
|
|
The application of Megmitte industrial control products in high-speed precision CNC machine tools
With the rapid development of the machinery manufacturing industry, the traditional general machine tool can no longer meet the changing parts processing needs of the shopping mall. CNC machine tools have undeniably become the mainstream processing equipment of today's machinery manufacturing. In response to the special application needs of the machine tool industry, Megmeet has launched the MV series of high-function ...
|
|
Common faults of Megmeet drives and how to deal with them
1. When the oscilloscope looks at the current monitoring output of the driver, it finds that it is all noisy and cannot be read
Cause: The current monitoring output is not blocked from the AC power supply (transformer).
Solution: You can use a DC voltmeter to detect and investigate.
2. Servo motor high speed ...
|
|
Megmeet inverter - maintenance precautions and items for high-voltage inverters
Precautions for maintenance of high-voltage inverters
1. Carefully monitor and record the display parameters on the man-machine interface of the inverter, and reflect the abnormality immediately
2. Carefully monitor and record the ambient temperature of the inverter room, and the ambient temperature should be between -5 °C and 40 °C. Phase-shifting transformers ...
|
|
Megmeet PLC – How does PLC communicate with computers?
1. In this computer, right-click, manage, check to find the device manager, plug in the USB-PPI cable (one end is connected to the computer, the other end is connected to the PLC), the computer device manager will pop up the port USB-SERLAL CH304 (com3), the number in parentheses may change, indicating that you have found the cable. This...
|
|
Megmeet PLC - the basic composition of PLC
a. Power supply
The power supply of the PLC plays a very important role in the whole system. It can't work properly without a good and reliable power supply system, so PLC manufacturers also attach great importance to the design and manufacture of power supplies. General AC voltage fluctuations are +10% (+15%) ...
|
|
Megmeet welding machine - the application and precautions for the use of butt welding machine
The butt welding machine should be settled indoors, and should have a reliable grounding or zero connection, when a plurality of butt welding machines are connected to each other, the distance from each other shall not be less than 3m, and they should be connected to different corresponding power grids, and should have their own knife switches.
Before welding, the pressure of the butt welder should be checked and determined.
|
|
Megmeet MC100 series plc – the right hand man in refrigeration equipment
First, the process requirements
When the low-pressure pressure collected by the system is greater than the upper low-pressure pressure set by the touch screen, the compression time will be loaded according to the set loading time, and the lower pressure will be reduced according to the set load reduction time.
The high pressure collected is greater than that on the high pressure ...
|
|
Megmeet PLC - the core components of PLC introduction
(1) Central Processing Unit (CPU)
The central processing unit (CPU) is the control center of the PLC. It accepts and stores user programs and data typed from the programmer, checks the status of the power supply, memory, I/O and alert timer in accordance with the functions assigned by the PLC system program, ...
|
|
The principle of Megmeet plasma cutting and its characteristics
5) PLASMA
The principle of plasma cutting is: arc discharge between the base metal (including the nozzle in the cutting torch) and the electric in the cutting torch, and use the discharge heat energy to make the compressed gas produce a high-temperature and high-speed plasma arc to fuse the cutting method of the base metal. The small hole of the nozzle ...
|
|
Megmeet welding machine - the working principle of the spot welding machine and its advantages and disadvantages are introduced
Safety operation procedures for spot welding machines:
1. Before operation, the oil stain of the upper and lower electrodes should be removed. After power-on, the body shell should be free of leakage.
2. Before starting, the steering switch of the control line and the small switch of welding current should be connected, the number of poles should be adjusted, and then the water source and gas source should be connected.
|
|
Megmeet inverter - maintenance precautions for high-voltage inverter
1. Carefully monitor and record the display parameters on the man-machine interface of the inverter, and reflect the abnormality immediately
2. Carefully monitor and record the ambient temperature of the frequency conversion room, and the ambient temperature should be between -5 °C and 40 °C. The temperature rise of the phase-shifting transformer should not exceed 130°C
3. Summer temperature ...
|
|
Megmeet inverter - precautions for inverters at high temperatures
1. Carefully monitor and record the display parameters on the man-machine interface of the inverter, and reflect the abnormality immediately;
2. Carefully monitor and record the ambient temperature of the frequency conversion room, and the ambient temperature should be between -5 °C and 40 °C. The temperature rise of the phase-shifting transformer should not exceed 130°C;
3. Summer ...
|
|
Various welding methods for Megmeet welding machines
1) Hand arc welding (STICK)
Shielded Arc Welding (abbreviated SMAW) in English,
The principle is: the arc occurs between the coating electrode and the base metal, and the welding method of arc thermal ablation electrode and base metal is used. The outer layer of the electrode is covered with solder, which is dissipated in case of heat.
|
|
Megmeet PLC - Comparison of the advantages of PLC and DDC in building automation systems
1. Application field: The initial design goal of PLC is only to replace complex relay circuits, and DDC is originally only used in industrial automation instruments: PLC emphasizes versatility, DDC emphasizes specificity: PLC is used in the field of industrial control, and DDC is used in professional building systems.
2. Structural differences ...
|
|
Megmeet inverter - the basic method and steps of inverter commissioning
1. No-load energizing test of inverter
1. Ground the grounding terminal of the inverter.
2. Connect the power input terminal of the inverter to the power supply through the leakage maintenance switch.
3. Check whether the factory display of the inverter window is normal, if it is incorrect, it should be reset, otherwise it should be ...
|
|
Megmeet inverter – the inverter's protection of itself, the motor and the system
1. The inverter protects itself
Instantaneous overcurrent, overvoltage, undervoltage, overload, short circuit to ground, abnormal control circuit, then for the protection of the inverter itself, the limit value of overcurrent, overvoltage, undervoltage, etc., when the inverter is running, if it exceeds ...
|
|
Megmeet inverter mv600 alarm code ENOC2
1. If there is a sharp acceleration or deceleration, please extend the acceleration and deceleration time.
2. Avoid rapid increase in load.
3. Check whether there is a short circuit in the UVW of the motor terminal.
4. The module is damaged, and the drive circuit is damaged, resulting in an overcurrent alarm.
...
|
|