Advantech Switches – Introduction to the functions of industrial switches

Create Date: 2024-8-30 12:03:23|Source: Advantech/Advantech

1. Cybersecurity

In advanced industrial applications, cybersecurity has become an issue to be solved. Many domestic manufacturers (such as Dongtu, Mosa, Mabwell, etc.) have produced a series of Web managed industrial switches that provide a variety of functions for network security problems in LAN.

1. Password—Have multiple levels of user passwords to avoid unauthorized access and settings.

2. Enable/Disable Ports Open and Close Ports — Closes unused ports.

3. 802.1q VLAN: A predefined WLAN on an industrial switch implements logical isolation between physical ports.

4.802.1x Port-Based Network Access Control—Locks down the ports of industrial switches so that they can only allow legitimate users to communicate.

5. MAC Based Port Security – Protects the ports of industrial switches so that they can only communicate with specific devices or MAC addresses.

2. Port device status

Set the rate, duplex, auto-negotiation, flow control, and more for each port to establish the correct connection with devices that are non-negotiable or have specific settings.

3. Port Rate Limit

Configure rate limits for ports, including ingress and egress speed limits. The types of port throttling include all unicast packets, multicast packets, and broadcast packets. where ingress speed refers to the actual speed at which the flow from other devices such as PCs to the ports of industrial switches. Egress velocity refers to the actual speed at which an industrial switch port flows between devices that use it. If both the ingress and egress speeds between the two device connection ports are limited, the actual speed is the lesser of the two.

4. Storm suppression storm

Wreak havoc on the network and cause failure of network-connected devices. In business-critical applications, it can be catastrophic. Filter broadcast packets based on user-defined limits to suppress the occurrence of storms.

5. Quality ofService (IEEE802.1p)

Industrial switches are based on frame buffer queues and first-come, first-served processing mechanisms, which will cause delays when the network load is large. IEEE802.1p allows packets in the high priority queue to stay in the industrial switch for a shorter period of time, and the opposite is true for packets in the low priority queue.

6. Virtual LAN VLAN (IEEE802.1q)

A virtual local area network (VLAN) is a method of creating an independent and separate logical network from a physical network, which enables several virtual LANs to exist in a physical network at the same time. VLANs can effectively reduce the broadcast range and facilitate network management. In fact, if you add a router between these different virtual network segments, they can still exchange data through the router. VLANs can effectively suppress the occurrence of broadcast storms.

7. Multicast Snooping for IGMP

A Layer 2 device running IGMP Snooping analyzes the received IGMP packets, establishes a mapping relationship between the port and the MAC address multicast address, and forwards multicast data based on the mapping. When the Layer 2 device does not perform IGMP snooping, multicast data is broadcast at Layer 2. When IGMP Snooping is run on a Layer 2 device, the multicast data of the known multicast group is not broadcast at Layer 2, but is multicast to the specified recipient at Layer 2.

8. MW-Ring

MW-Ring allows industrial switches to be connected as redundant links, and when one of them is disconnected, the other link can be quickly and automatically restored. In the event of a network outage or network failure, it has link redundancy and fast self-recovery capabilities. MW-Ring technology is developed and designed by Wuhan Mabwell Communication Co., Ltd. for high-reliability industrial control network applications.

9. Link aggregation (802.3ad)

THE MAIN FUNCTION OF PORT AGGREGATION (TRUNK) IS TO BIND MULTIPLE PHYSICAL PORTS (USUALLY 2-4) INTO A LOGICAL CHANNEL, SO THAT IT WORKS LIKE A CHANNEL. After bundling multiple physical links together, not only improves the bandwidth of the entire network, but also allows data to be transmitted through multiple physical links that are bound at the same time, which has the effect of link redundancy, and when one or more of the links are disconnected due to network failure or other reasons, the remaining links can still work.

10. Rapid spanning tree RSTP

Spanning Tree Protocol (PAP) is a Layer 2 management protocol that selectively blocks redundant network links to eliminate network Layer 2 loops and provides link backup functions.

11. Port-based network access control (802.1x)

A port-based network access control mechanism is defined to provide a method for authenticating and authorizing devices connected to LAN ports.

12. HTML Web Browser

A simple, intuitive user interface for setup and monitoring is provided via a standard graphical web browser. All system parameters, including detailed online help, are a breeze with system settings.

13. SNMP (Simple Network Management Protocol)

The Simple Network Management Protocol (SNMP) is defined by the Internet Engineering Task Force and is part of the Internet Protocol that makes up the Internet Protocol. When a network device is concerned, SNMP is used to monitor network devices through the network management system. The SNMP protocol consists of a series of standard network management, application layer protocols, databases, and data objects.

14. Port mirroring

Port mirroring is to copy all the data sent and received from one or more ports to another specified port. By specifying a port as a mirror port for other ports, you can observe all the data sent and received on other ports through that port. The port mirroring function is used to diagnose, debug, and analyze network faults.

15. Port Statistics and Remote Monitoring (RMON)

Each port provides continuously updated statistics, including all incoming and outgoing packet counts and byte counts, as well as detailed error statistics. It also provides all support for RMON statistics, history, alarms, and event groups. RMON can complete accurate data collection, analysis, and data flow model detection.

16. NTP (Simple Network Time Protocol)

The internal clock of the system is automatically synchronized with the NTP server in the network, thus providing the time correlation of events for failure analysis.

XVII. Event recording and alarm

All major events are logged into a nonvolatile system log for future failure analysis. Events include link failure and recovery, unauthorized access, broadcast storm detection, and self-test diagnosis. Alarms provide a snapshot of the most recent events that have occurred and the network administrator has not yet responded. An external hardware relay releases the contacts during a major event, allowing the external controller to operate if necessary.
Advantech Switches – Introduction to the functions of industrial switches

More on that
Advantech IPC - Introduction to the technical characteristics of IPC IPC Advantech IPC - Introduction to the technical characteristics of IPC IPC

1. The all-tempered industrial chassis that fully conforms to the "EIA" standard is adopted, which greatly enhances the ability to resist magnetic field interference. 2. Using bus structure and modular design, all functional modules of the CPU can be suitable for plug-in structure, and also have a soft lock of the pressure rod, which can better resist impact.

How to set up Advantech's motherboard BIOS How to set up Advantech's motherboard BIOS

1. Set the system date and time In the standard BIOS settings interface, you can correct the date and time of the system by pressing the arrow keys to move the cursor to the Date and Time options, and then pressing the Page Up/Page Down or +/&S722 buttons. 2. IDE interface ...

Advantech Motherboards – What is the difference between industrial motherboards and embedded motherboards? Advantech Motherboards – What is the difference between industrial motherboards and embedded motherboards?

What is an Industrial Motherboard? An industrial control motherboard is a motherboard used in industrial applications. They are used by industrial computers. They can adapt to a wide range of temperature environments, can adapt to harsh environments, and can withstand high loads for long periods of time. According to the structure and size of the industrial control motherboard, it can be ...

Advantech and Yuxin jointly launched a lung sound detection system Advantech and Yuxin jointly launched a lung sound detection system

Advantech, an industrial computer manufacturer, today announced the AI continuous lung sound monitoring system of the excellent team in the start-up stage of the concerted efforts of Yuxin Medical Machinery Innovation Technology and Integrated IC Large and Medium-sized Factories Intel announced each other's AI continuous lung sound monitoring system, and the future hospital only needs 1 edge measurement network server to test the breathing of 24-bed patients.

Advantech Switches – Introduction to the functions of network switches Advantech Switches – Introduction to the functions of network switches

Learning function: The Ethernet switch learns the MAC address of the device connected to each port, maps the address with the corresponding port, and stores it in the MAC address table in the switch cache. Forwarding Filtering: When the destination address of a data frame is mapped in the MAC address table, it is ...

Advantech assisted Pingtung Veterans in building the first large-scale closed-loop medication management hospital in Taiwan Advantech assisted Pingtung Veterans in building the first large-scale closed-loop medication management hospital in Taiwan

Advantech, a major industrial IoT manufacturer, recently announced that it has assisted Pingtung Veterans General Hospital with an innovative medication management model for the Internet of Things, making it the first hospital in Taiwan to introduce closed-loop medication administration (CLMA) on a large scale.

Advantech MicroATX industrial motherboard model parameter introduction Advantech MicroATX industrial motherboard model parameter introduction

The size of the Micro-ATX industrial motherboard is 244 x 244 mm, and the main features are low cost, moderate expansion ability, and are most suitable for design space requirements. MicroATX Industrial Motherboards ...

Advantech's industrial-grade 4G LTE router and gateway model introduction Advantech's industrial-grade 4G LTE router and gateway model introduction

The ICR-3200 LTE 4G Series Advantech Industrial Grade Cellular Routers and Gateways are the perfect way to connect Ethernet and RS232/RS458 devices to cloud-scale platforms as well as taditiona industrial systems and SCADA over cellular networks. ICR-3200, with its powerful CPU and enhanced memory, it is ...

Advantech motherboard: How to set up hard disk boot Advantech motherboard: How to set up hard disk boot

1. Enter BIOS: Turn on or restart the computer, and press the DEL key on the keyboard when the boot screen appears to enter the BIOS setting table. 2. Once in the BIOS settings, use the arrow keys on your keyboard to move to the Advanced menu option and find SATA Config in it...

Hardware failure of the switch Hardware failure of the switch

(1) Power failure: Due to the instability of the external power supply, the power supply may be damaged due to aging power lines, lightning strikes, etc., or the fan may stop, so that the normal operation cannot be carried out. It is not uncommon for other parts of the machine to be damaged due to the power supply. If the face ...

Advantech's FPM series of industrial panel PCs touchscreen HMIs Advantech's FPM series of industrial panel PCs touchscreen HMIs

Advantech's industrial-grade flat panel display FPM series has a wide operating temperature range of -20°C~ 60°C, making it suitable for harsh industrial environments. The FPM series features an excellent industrial-grade LCD display for a more realistic display. The industrial grade flat panel display FPM series is designed for factory ...

How does Advantech's IPC reinstall the system? How does Advantech's IPC reinstall the system?

Take Advantech IPC 610L as an example of how to install win7 system To install the image win7, you need to make the following preparations: (1) Make a USB flash drive boot disk first; (2) Download a win7 system image file, and then copy it to the USB flash drive boot disk; Step 1: Combine the production of ...

Advantech's daily maintenance of the IPC and what to pay attention to in the process Advantech's daily maintenance of the IPC and what to pay attention to in the process

Advantech's daily maintenance and maintenance of IPC: 1. Advantech's industrial computer should first provide him with a relatively stable working environment when it is used, so as to prevent frequent sensations in the process of use, otherwise it will affect its internal disks and hard disks, and simply form a serious grinding of the drive.

Advantech Technology Co., Ltd. IPC-510 IPC chassis model configuration Advantech Technology Co., Ltd. IPC-510 IPC chassis model configuration

Advantech industrial computer is one of the leading industrial control products in China and the world, the most commonly used, to IPC-510, IPC-610L, IPC-610H these series, many customers directly take this model to inquire, but this is only a Advantech chassis model, the original configuration of the whole machine still needs to ...

Advantech's industrial computer savings soared to a new high Advantech's industrial computer savings soared to a new high

Advantech, a major industrial computer manufacturer, has shaken off the impact of the new crown pneumonia epidemic in its second-quarter operation, and the company's estimated operating income is expected to be almost the next highest level compared with the same period last year, and the reasonable pace of enterprise project investment has not stopped, and the outlook for the market outlook is still good. Advantech opened higher today and rose faster ...

Advantech Industrial Motherboard - Classification and introduction of IPC motherboards Advantech Industrial Motherboard - Classification and introduction of IPC motherboards

1. ATX motherboard: ATX is a motherboard specification formulated by Intel Corporation in 1995, which is the first major change in the design of computer cases and motherboards in many years. The more common ATX motherboard, large rectangle, generally 7 expansion slots, the size is about 305x244mm. ATX boards are still ...

What is the reason why Advantech's IPC does not respond when it is turned on? What is the reason why Advantech's IPC does not respond when it is turned on?

1. Confirm whether the power supply of Advantech IPC is connected normally, whether the power supply is turned on, and whether the power cord is plugged in. Confirm that the motherboard power connection is correct and that the motherboard is in working condition. Check whether the CPU is plugged in correctly and whether the CPU power connection is normal. 2. Inspection Advantech ...

Thermal analysis of Advantech's industrial computer  Thermal analysis of Advantech's industrial computer 

According to statistics, dust, heat dissipation, and static electricity are the three main factors that cause computer instability. However, due to the different use environments, commercial PCs only comply with AT, ATX, and even the latest BTX architecture in terms of heat dissipation, and the dust and static electricity problems are not prominent in ordinary use environments.

Advantech IPC - the main structure of IPC IPC Advantech IPC - the main structure of IPC IPC

1. The all-steel chassis of IPC is designed according to the standard, anti-shock, anti-vibration, anti-electromagnetic interference, and a passive base plate compatible with PC-bus can be installed inside. 2. The slots of the passive backplane are composed of multiple slots of ISA and PCI bus, and the number of ISA or PCI slots is ...

Steps to set up the gateway for Advantech switch EKI-2528 Steps to set up the gateway for Advantech switch EKI-2528

Step 1: Configure VLAN For the management IP address of the switch on the network, it is recommended to divide a dedicated VLAN, such as VLAN 1000, to isolate it from the VLAN of the user terminal. Command vlan 1000 step 2: Configure VLANIF interface address Assume the ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top