Reduce the maintenance cost of the inverter - Delixi

Create Date: 2024-8-30 12:03:23|Source: Delixi

Frequency converter is a widely used equipment in modern factories. This is a very expensive new type of equipment, and the maintenance price of the inverter is also very expensive, so in the process of using the inverter, we should pay attention to the use of the inverter.

                              Reduce the maintenance cost of the inverter - Delixi

The physical environment is an aspect that has an important impact on the use of the inverter, according to the professional and technical personnel who repair the inverter and his repair experience, most of the problems of the inverter are formed by the logistics environment of the inverter, mainly including the following three aspects:

1. Working temperature: the inverter has a lot of electronic components, some of which will change the performance with the change of temperature, and some will even be damaged by the temperature, therefore, it is recommended to control the normal working temperature of the inverter between 0-55 °C, and some simple heating items should not be connected to the inverter.

2. Ambient temperature difference: If the ambient temperature changes too much, condensation will occur in the inverter due to the temperature difference. When the inverter is started, it is simply burned out due to short circuit inverter and other reasons, therefore, in the place where the temperature difference between day and night is large, put some desiccant in the inverter, which will greatly remove condensation.

3. Corrosive gases. The internal electronic components of the inverter are not corrosion-resistant, and should not touch corrosive liquids and solids, but corrosive gases can also cause damage to the components, so it is necessary to prevent excessive contact between corrosive gases and inverters.

More on that
Delixi spare parts replacement cycle Delixi spare parts replacement cycle

1. Cooling fan (2-3 years) As long as the inverter is in use, the cooling fan has always been running, so the cooling fan is generally a short-service life accessory, generally after the use of the cooling fan for 2-3 years, the bearings, balls, motors, etc. of the fan are seriously worn, and they need to be replaced.

The difference between air switch and leakage protection switch - Delixi The difference between air switch and leakage protection switch - Delixi

(1) The function is different. An air switch is a kind of circuit breaker that maintains "something", which can maintain the safety of the entire household wiring and appliances, and avoid the overheating and burning of the wires. The leakage maintenance switch is a kind of circuit breaker for maintenance personnel, which can block the circuit in time when leakage is carried out to avoid the danger of electric shock.

Delixi responds to the national strategy to enter the field of high-end production Delixi responds to the national strategy to enter the field of high-end production

Electrical manufacturing is the main business and the old bank of Delixi, in recent years, the group has vigorously implemented the high-quality transformation and development strategy, and has always adhered to the intelligent manufacturing as a new engine to enhance the benefits per mu, with the construction of intelligent factories as the carrier, with the key manufacturing links as the core, and constantly increase scientific research ...

Delixi single-phase inverter CDI-EM60 series manual Delixi single-phase inverter CDI-EM60 series manual

Read this statement carefully before installing, operating, maintaining, and viewing the EM60 series drives. In order to ensure the safety of your person, equipment and property, please be sure to read carefully before using our EM60 series inverter.

The structure of the inverter - Delixi The structure of the inverter - Delixi

The main circuit is the power conversion part that supplies the voltage regulation and frequency modulation power supply to the asynchronous motor, and the main circuit of the inverter can be roughly divided into two categories: the voltage type is the inverter that converts the DC of the voltage source into a communication inverter, and the filter of the DC loop is the capacitor. The current type is to convert the DC of the current source into a communication ...

Leakage protector leakage cause - Delixi Leakage protector leakage cause - Delixi

1. Poor device If the terminal posts of the leakage protector are not firmly connected during the installation, it will often lead to the heating and oxidation of the terminal post for a long time, so that the wire insulation layer will be scorched, and accompanied by the smell of ignition and rubber and plastic burning, forming an undervoltage of the line and tripping the leakage protector. ...

Delixi general inverter E100 series products introduction Delixi general inverter E100 series products introduction

E100 series products are a standard inverter with optimized open-loop vector control, V/F control, stable performance, rich functions, optimized structural design, exquisite appearance, and high cost performance. Technical features: ...

Delixi reduces the number of inverter maintenance times Delixi reduces the number of inverter maintenance times

Inverter is a very widely used equipment in the modern factory, this is a new type of equipment, the price is very noble, and the price of inverter repair is also very expensive, so in the process of using inverter, pay attention to the use of inverter, on the one hand, inverter, delay inverter ...

Delixi launched a series of new products of "product intelligence". Delixi launched a series of new products of "product intelligence".

Delixi Electric launched a new "product intelligence" series of products, with outstanding quality and higher cost performance of professional competitiveness, to meet the green consumption demand for low-voltage electrical appliances in the field of construction and real estate, and promote China's low-voltage electrical profession into a new green development era. This "product wisdom" ...

Delixi voltage regulator fault phenomenon and analysis Delixi voltage regulator fault phenomenon and analysis

Delixi regulator output voltmeter keeps swinging back and forth, and sparks occur at the carbon brush, and the problem phenomenon and cause analysis 1. The contact pressure between the carbon brush and the coil plane is too small 2. The carbon brush is severely worn Delixi voltage regulator has ...

Causes and solutions for circuit breaker closing failure - Delixi circuit breaker Causes and solutions for circuit breaker closing failure - Delixi circuit breaker

1. Failure analysis. 1) Closing fuse, control fuse blowing or poor contact. 2) Poor contact of DC contactor or poor contact of control switch contact and auxiliary contact of circuit breaker. 3) The DC voltage is too low. 4) Closing and locking action. ...

Delixi CDM molded case circuit breaker upgrade Delixi CDM molded case circuit breaker upgrade

The 6 series electronic molded case circuit breaker CDM6Ei was launched in 2017 with the addition of a 1600A shell frame; High through-off capacity, *** high Ics=65kA, to meet specific application occasions; Long-distance four-remote communication to complete intelligent connectivity; Support mobile APP communication and alarm non-tripping function; The maximum operating temperature of the product can be ...

Delixi power transformer protection role Delixi power transformer protection role

In most large electrical systems, generators and power transformers are the two most expensive pieces of equipment. In addition to the capital cost of purchase, the continuity and reliable operation of these two key equipment systems are also the most critical. For example, the test ...

The role of Delixi AC voltage regulator The role of Delixi AC voltage regulator

Delixi high-precision fully active AC voltage regulator uses linear integrated circuits to form a control system, controls the servo motor, drives the contact voltage regulator to actively regulate the voltage, and is equipped with delay, overvoltage, undervoltage and overcurrent maintenance functions. The product has high efficiency, the same input and output voltage waveforms, and the output ...

Delixi voltage regulator safety installation method Delixi voltage regulator safety installation method

In people's lives, voltage regulators are not short, but some people do not install voltage regulators correctly, which leads to great safety hazards in the use of voltage regulators. Here's how to properly install the regulator: ...

Delixi solid state relay over AC contactor advantages Delixi solid state relay over AC contactor advantages

Delixi solid state relay and Delixi communication touch device are more used products, so what are the advantages of solid state relay compared to communication touch device, how should we choose when we can choose? 1. First of all, solid...

Analysis of the quality of Delixi surge protector Analysis of the quality of Delixi surge protector

Look at the quality of the surge protector, to see whether it can complete his basic specification, relative to the surge protector of the primary specification is whether the surge operating voltage can be constrained below the required value, the surge protector must discharge the lightning current when the mission is completed, this specification must be completely completed.

Delixi surge protector knowledge quiz Delixi surge protector knowledge quiz

Many people don't know what a surge is, surge is also known as a surge or lightning protection maintainer, the first is to maintain the household electrical equipment when it rains and thunders to avoid being damaged by lightning, and when the lightning strikes high-voltage electricity is drained to the ground through the surge maintainer, it will not directly hit the electrical equipment ...

The general principle of circuit breaker selection - Delixi The general principle of circuit breaker selection - Delixi

(1) The additional operating voltage of the circuit breaker ≥ the additional voltage of the line. (2) The additional current of the circuit breaker ≥ the line load current. (3) The additional short-circuit of the circuit breaker can be turned on and off to ≥ the maximum shortness that may be present in the line.

Parameters of Delixi inverter speed controller Parameters of Delixi inverter speed controller

(1) Gain Parameter: The share gain of the speed manipulator. If the gain is too large, it may cause speed fluctuations. (2) Integration time parameter: the integration time of the speed manipulator, that is, the change rate of the output signal of the manipulator under the deviation step signal. The shorter the integration moment ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top