There are many types of three-phase communication regulators in Delixi, the most commonly used ones are SJW and SBW, etc., so we need to pay attention to the process of application:
First of all, it must be operated correctly in accordance with the instructions of the voltage regulator, due to the fault may damage the voltage regulator, reduce the service life of the voltage regulator, if the scale is exceeded, in the case of too low voltage, it is necessary to add a transformer alone to boost the voltage, so it is more troublesome. Therefore, before customizing, it is necessary to understand the relevant regulations.
And the selection of voltage regulators must pay attention to the technical parameters of the product, due to the different technical parameters of the use of different scale, Delixi three-phase communication regulator in the customization of the time requirements in accordance with the relevant provisions of the country to customize, communication regulator in the daily life of the application of a wide range of scope, but there are some areas of demand for customization.
When using the regulator, it is necessary to place it on a flat ground to prevent the regulator from vibrating violently, and it is easy to make the components inside the regulator fall off. When wiring the voltage regulator equipment, it is necessary to equip the wire with a thickness according to the rated power, and it is better to be thicker than to save this money. It is also necessary to ensure that the voltage regulator is placed in a clean space to prevent too much dust after long-term use of the voltage regulator, which may affect the touch and accuracy of the voltage regulator.
The final voltage regulator in different areas of the use of requirements are not the same, in the selection of this Delixi three-phase communication regulator to be selected according to the local conditions, such as the city in the seashore, then the Delixi three-phase communication regulator shell has certain requirements, this shell needs to be anti-corrosion. Since this electrical device is very simple to be. Water evaporation may corrode. Of course, the IP protection level should also be improved, especially the customization of the shell should play a protective role.
|
More on that
|
Thermal calculation of linear regulator - Delixi
Thermal accounting requires information such as power loss, thermal resistance of the package, and ambient temperature. The power loss is the same as the power accounting, which is purely the value of the output input voltage difference multiplied by the input current. The thermal resistance should have a technical standard documented, and if it is not, it is necessary to ask the manufacturer. Basically...
|
|
Delixi air switch object, structure, principle
Application of air switches (circuit breakers).
Delixi air switch, also known as circuit breaker. It is a switch that actively closes as soon as the current in the circuit exceeds the additional current. Air switch is a very important electrical appliance in the low-voltage distribution network and electric traction system.
|
|
The difference between Delixi single-phase and three-phase AC voltage regulators
Delixi's communication regulator is divided into single-phase communication regulator and three-phase communication regulator. Among them, the types of single-phase communication regulators are mainly TND, TND3, AVR, JJW-D, DBW and other types; The types of three-phase communication regulators are mainly SJW, JJW-S, SBW and so on.
...
|
|
Delixi CDF1 isolation switch introduction and the difference with the transfer switch
Delixi CDF1 load isolation switch, the product material is carefully selected, with the advantages of reliability and durability. At the same time, it is locked when the power is on, and it can only be turned on when the power is off, which effectively avoids the occurrence of electric shock accidents.
The contacts are made of high-quality copper ...
|
|
Delixi inverter load type and selection points
The correct selection of the inverter is very important for the normal operation of the control system. When selecting an inverter, it is necessary to have a thorough understanding of the load characteristics driven by the inverter. In practice, people often divide production machinery into three types: constant torque load, constant power load and fan and pump load. ...
|
|
Introduction of four-quadrant regulator - Delixi
A four-quadrant power supply is a power supply capable of absorbing and supplying positive and negative currents and voltages. While a simple voltage converter is capable of generating a fixed output voltage from the input voltage, this feature is not sufficient in some applications. An example is the control of voltage nodes connected to capacitors that ...
|
|
Delixi AC contactor fault causes and solutions
First, the iron core may not be able to suction power
Causes: The power supply voltage is too low or fluctuates too much, the power supply capacity of the operating circuit is lacking or the wire is broken and the control contact is poor, the technical parameters of the coil are inconsistent with the application conditions, and the product itself is damaged.
Solution: Turn up the power ...
|
|
Delixi launched a series of new products of "product intelligence".
Delixi Electric launched a new "product intelligence" series of products, with outstanding quality and higher cost performance of professional competitiveness, to meet the green consumption demand for low-voltage electrical appliances in the field of construction and real estate, and promote China's low-voltage electrical profession into a new green development era. This "product wisdom" ...
|
|
Linear regulator and switching regulator concept - Delixi
01. What is a linear voltage regulator?
A linear regulator uses a transistor or FET that operates in its linear region to subtract the excess voltage from the input voltage applied to generate a conditioned output voltage.
The so-called voltage drop voltage means that the voltage regulator maintains its output voltage at its ...
|
|
Delixi Electric CDW3 universal circuit breaker introduction
The CDW3 series frame circuit breakers are rated from 400A to 6300A and 415V/690V AC for extreme environmental conditions of 50 Hz AC and -40°C to 70°C. It is mainly used in the distribution network, distributing electric energy, protecting lines and power supply equipment from ...
|
|
Delixi molded case circuit breaker external two tripping wire connection
The molded case circuit breaker tripper is divided into undervoltage tripper and shunt tripper. This article explains the wiring method of the circuit breaker with sub-excitation tripper. The shunt tripper is often used as an additional accessory for the user, it is a remotely operated circuit breaker disconnection device, installed in the molded case circuit breaker, when the shunt ...
|
|
Delixi low-voltage AC contactor can not be suction reason
AC contactor can sometimes be used for a long time can not be suction situation, although this is not a common problem of AC contactor, but AC contactor can not be suction will affect the efficiency of the operation and even damage the production equipment, with the equipment for too long, together without outstanding maintenance, are ...
|
|
Noise characteristics of different switching regulator topologies - Delixi
Currently, there are many different switching regulator topologies. Some topologies are widely used, such as the classic buck converter, also known as the buck converter. However, there are also some lesser-known switch-mode DC-DC converters that include Zeta topologies. These topologies are divided into fundamental topologies ...
|
|
The cascade protection of Delixi circuit breaker
In the design of Delixi power distribution system, the selective cooperation between the upper and lower levels of the circuit breaker must have "selectivity, rapidity and sensitivity".
Selectivity is related to the cooperation of the upper and lower circuit breakers, and the speed and sensitivity are related to the maintenance of the characteristics of the appliance itself and the way the line operates ...
|
|
Delixi circuit transformation attention to detail
1. If strong electricity and weak electricity are to be separated by a long distance from the horizon walking line, the interval should generally exceed 30 cm to prevent disturbance and be interspersed with each other.
2. In order to facilitate the future line change, the PVC pipe must be cut down and straightened as much as possible.
|
|
Inverter application skills - Delixi
1. Shielded wires should be used for signal lines and control lines, which is beneficial to avoid disturbance. When the line is long, for example the distance jumps 100m, the conductor cross-section should be enlarged. The signal line and the control line should not be placed in the same cable trench or tray with the power line, so as not to disturb each other, it is best to place it through the pipe, ...
|
|
Leakage protector leakage cause - Delixi
1. Poor device
If the terminal posts of the leakage protector are not firmly connected during the installation, it will often lead to the heating and oxidation of the terminal post for a long time, so that the wire insulation layer will be scorched, and accompanied by the smell of ignition and rubber and plastic burning, forming an undervoltage of the line and tripping the leakage protector.
...
|
|
Delixi leakage protector tripping causes and solutions
1. The leakage protector does not match the load. This situation mostly occurs when using high-power electrical appliances, and it is generally only necessary to replace the leakage protector that matches the practical needs from scratch.
2. Check whether the switch wiring is correct, ...
|
|
Problems in the installation and use of Delixi voltage regulator
What is the voltage regulator can not be connected in parallel, the voltage regulator is not open for a long time, what will be the problem with the voltage regulator still open under normal voltage, is it said that the voltage regulator and the undervoltage lamp is not lit to clarify that the voltage regulator is normal?
Will a normally open regulator burn it out at normal voltage?
...
|
|
The cause of the abnormality of the motor controlled by the inverter
The first method is that you can analyze what the cause is according to the condition displayed on the inverter, such as whether the faulty code appears normal, whether there is still running code or not, and still nothing appears (in the case of input power), which means that there is a rectification problem. If you're on standby...
|
|