Dense busway with high insulation – Wienal

Create Date: 2024-8-30 12:03:23|Source: Woehner/Wiehner

The dense busway is made of structure, with high mechanical strength, good sealing, fast heat generation, good shielding function and anti-chimney effect.

The conductor is constructed to overcome edge discharge and acute angle damage to the insulation.

                           Dense busway with high insulation – Wienal

The insulation is made of extruded fully enveloped structure, which is seamless, dustproof and waterproof, with strong insulation function and high voltage resistance level.

The connection is made of non-piercing double spring plate structure, the cross-sectional area of the conductor is not reduced, the contact surface of the conductor is evenly stressed, and the danger of short circuit of the bus system is easily formed by the piercing bolt structure, and the installation is more convenient and fast than the traditional way.

More on that
Bus load forecasting method and characteristics - Wiener Bus load forecasting method and characteristics - Wiener

Bus load guessing is a kind of power system load guessing, and the bus system load can be defined as the sum of the terminal load supplied by the main transformer of the substation to a relatively small power supply area, which is the refinement of the system load. Bus load guessing generally only carries out short-term load guessing, and the result is ...

Advantages of cable tray installed in busway Advantages of cable tray installed in busway

At the time of the cable tray installation, the wiring is not very convenient. This phenomenon can be avoided by using busway. The 5 advantages of using busway in the cable tray device are as follows: 1. Convenient connection of bus duct: the so-called plugging ...

What is the difference between a Wiener busbar and a cable What is the difference between a Wiener busbar and a cable

The difference between busbar and cable The busbar is used to gather current. Many power and power supply circuits are connected to the bus, through which the power is gathered and sent to each circuit. Therefore, the current carrying capacity of the bus bar is relatively large, and the current carrying capacity of the bus ...

The connection method of the tubular busbar The connection method of the tubular busbar

In the industry, tubular bus bar can be described as one of the more common equipment, with high mechanical strength, good insulation, wide range of application and other characteristics of many enterprises. So do you know what are the ways to link tubular busbars? ...

The advantage of closed busbar over open busbar is Wiener The advantage of closed busbar over open busbar is Wiener

1) Closing the bus duct can reduce the grounding fault, prevent the short circuit between the phases, and fundamentally eliminate the grounding fault caused by external moisture, dust and foreign objects, and improve the continuity of generator operation. 2) Eliminate the surrounding ...

Features of busway power supply system - Wiener Features of busway power supply system - Wiener

1. Trunk power distribution system, simple wiring and reliable operation. 2. It is convenient to tap, and you can tap without cutting off the main power supply. Large power supply capacity up to 6300A current-carrying capacity. 3. High dielectric strength, strong overload, superior fire performance. Good heat dissipation performance, low impedance ...

Busway Installation Specification – Wiener Busway Installation Specification – Wiener

1: The basic requirements for the bus duct: 1) Conductor data: high-purity electrical copper drawn from national standard T2 electrolytic copper, with a purity of more than 99.9% and a full-length tinned copper conductor. 2) Shell: Select high-quality aluminum-magnesium alloy profiles that meet the strength, with heat dissipation ribs, and the appearance should be oxygen-proof.

Power system bus wiring features - Wiener Power system bus wiring features - Wiener

1) Single bus wiring. Single bus wiring has the advantages of simple and clear, less equipment, small investment, convenient operation and conducive to expansion, but the reliability and flexibility are poor. When there is a fault or maintenance of the bus bar or bus barrier switch, the full power supply of the bus must be disconnected. ...

A detailed description of the Wiener comb busbar and connection terminals A detailed description of the Wiener comb busbar and connection terminals

The Wiener comb busbars and connection terminals are available with QUADRON®CrossLinkBreaker in size 000/00 Recommended installation: Wire entry at the lower end of the NH-fuse disconnector through the comb busbar. In the mounting position ...

Precautions for the installation of explosion-proof distribution boxes - Vernal Precautions for the installation of explosion-proof distribution boxes - Vernal

The protection level mark of explosion-proof distribution box is the protection level of IP products that we often mention, which has two parameters, one represents the level of avoiding foreign objects from entering the shell, and the second represents the level of waterproof entering the shell. Installation of explosion-proof ...

A new product has been added to the world of CrossBoard® systems A new product has been added to the world of CrossBoard® systems

A new addition to the world of CrossBoard® systems: the MOTUS® hybrid motor starter with IO-Link interface is a new networking feature in the MOTUS® IO-Link family that enables continuous communication between the control and device levels. Control the delivery of instructions, control the parameters ...

The innovation of Wiener 185Power in the low-voltage main distribution system The innovation of Wiener 185Power in the low-voltage main distribution system

The new base system adapter creates a new type of solution in combination with the 185Power system, which was not possible before. CrossBoard® products can be easily connected to the adapter of the base system via the CrossLink® interface. Components of DIN support rails, e.g. fuses ...

Classification of busway – Vernal Classification of busway – Vernal

According to the different uses of the bus duct, the bus groove is generally composed of the start bus slot, the straight bus slot (without partition jacks and jacks), the L-shaped straight (horizontal) curve bus, the Z-shaped straight (horizontal) offset bus, the T-shaped straight (horizontal) tee bus, the X-shaped straight (horizontal) four-way bus, the transformer...

The content and steps of low-voltage cabinet maintenance - Wiener The content and steps of low-voltage cabinet maintenance - Wiener

1: The overhaul should start from the low voltage side of the transformer. After the power failure of the low-voltage cabinet, clean the dust in the cabinet to check whether the connection between the bus bar and the down conductor is outstanding, whether the connection is heated or discolored, whether the cable head and the terminal pile head are strong and reliable, whether the grounding wire is corroded, and whether the terminal pile head is tightened. Everything secondary ...

Busbar system reverse operation – Wiener Busbar system reverse operation – Wiener

(1) For the charging of the spare bus, when there is a bus tie circuit breaker, the bus tie circuit breaker should be used to charge the spare bus. At this moment, the maintenance device of the bus tie circuit breaker should be fully invested, and the relevant maintenance value and time limit should be changed to a smaller one, so as to facilitate the bus tie circuit breaker when there is a problem, the bus tie circuit breaker can quickly trip, cut ...

The essence of Wiener busbar technology The essence of Wiener busbar technology

1. Closed busbar hooking technology Circuit breakers and contactors can be hooked on the bus through the bus adapter, and fuse switches and other products are directly attached to the bus, so the bus bar plays a two-layer effect of conductive and fixed rotation.

Phase of the busway in the low-voltage incoming line – Wiener Phase of the busway in the low-voltage incoming line – Wiener

According to the requirements of the relevant specifications, the placement of the three-phase busbar can be roughly divided into two kinds according to the model of the low-voltage distribution cabinet and the different manufacturers: horizontal placement and placement of the down wire, according to the order of placement.

Distribution cabinet bus calculation method - Vilna Distribution cabinet bus calculation method - Vilna

1. The main bus at the upper end of the low-voltage distribution cabinet is calculated according to the material and cross-section in the extension meter. The bus bar connected to the main bus at the upper end of the switch is not accounted for and is included in the low-voltage distribution cabinet. 2. The transformer mainly depends on how large the load is, according to your switchgear can be calculated to match the transformer, but not the same...

Busway installation method - Wiener Busway installation method - Wiener

1. Busway horizontal device, the interval between the two brackets is ≯2500mm, and the interval between straight devices is ≯3600mm; 2. When the device bracket is straight, it should be drilled with the channel side plate and fastened with M6-M8 bolts. 3. In the process of installation construction, priority should be given to the power supply system, ...

The busway power system is a key component - Wiener The busway power system is a key component - Wiener

The busway is one of the more critical components in the power system, and it is an important part of connecting cables to important equipment such as substations, overhead lines, transformers, circuit breakers, etc. It is widely used in various power systems, mainly for the reliable operation of power systems. ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top