YBLX-WL travel switch is mainly used in the control circuit of AC 50Hz or 60Hz, voltage 380V, DC voltage 220V, for the travel control of the moving mechanism, the transformation of the direction or speed of the movement, the automatic control of the machine tool, the limit action of the moving mechanism and the control of the stroke or program.
Comply with standards: GB/T 14048.5, IEC 60947-5-1.
Degree of protection: IP52
Operation frequency: 20 times/min
Ambient temperature: -5°C - +40°C
Relative humidity: ≤90%(20C)
Rated voltage: AC-15:380VDC-13:220V
Rated control current: AC-15: 0.79ADC-13: 0.15A
Installation Category: II.
Pollution level: Level 3
Rated insulation voltage: 415V
Rated impulse withstand voltage: 4kV
Operating force: ≤20N
Stroke: ≤45°
Overtravel: ≥15°
This article introduces the interest of CHINT/CHINT YBLX-WL series travel switch products, please also contact our customer service, we are looking forward to your call, hope our technology and service can bring you a better experience.
The company has been customer-centric, the concept of creating value for customers, winning the market with quality and service, and sincerely hopes to cooperate with all sectors of society to create success, create brilliance together, and work together to create a better tomorrow! In line with the concept of credibility and service-oriented, the company warmly welcomes new and old customers to inquire, visit and negotiate business!
|
More on that
|
CHINT/CHINT DZ267LE-32 residual current circuit breaker
DZ267LE-32 residual current action circuit breaker (hereinafter referred to as residual current circuit breaker) is mainly suitable for AC 50Hz, rated voltage 230V, rated current to 32A circuit, as a personal electric shock, equipment leakage protection, and overload, short circuit protection function, can also be used in the positive ...
|
|
CHINT/CHINT Terminal Appliances —NU6-II Series Surge Protector
NU6-II. series surge protector is suitable for AC 50Hz, rated voltage of single-phase 230V/three-phase 400V power distribution and control system, to meet the SPDII. level test, used to suppress the transient overvoltage below the equipment withstand impulse overvoltage, discharge surge energy, so as to protect the system circuit and equipment.
Suitable...
|
|
CHINT/CHINT NXRC series contactor relays
NXRC series contactor relays are mainly used in relay control, signal transmission, isolation amplification and other circuits with AC 50Hz or 60Hz, rated working voltage to 380V and DC rated voltage to 220V, for switching, breaking and amplifying.
● Conform to standards: GB/T 14048.5, IE ...
|
|
CHINT/CHINT NCH8G Home AC Contactor NCH8G-25/02
NCH8G series household AC contactor (hereinafter referred to as contactor) is mainly suitable for AC 50Hz (or 60Hz), rated working voltage to 400V rated working current to 63A circuit, control household appliances and similar uses of low-inductance and micro-inductance loads; It can also be used to control household ...
|
|
CHINT/CHINT NM1 series plastic case circuit breaker
The circuit breaker is rated for insulation voltage to 800V (500V for NM1-63 type), suitable for AC 50Hz, rated working voltage to 690V (400V for NM1-63 type), rated working current from 10A to 1250A in the distribution network circuit, used to distribute electrical energy and protect the line and power supply equipment from overload...
|
|
CHINT/CHINT NXB-63H miniature circuit breaker
Rated current (In): 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A
Rated working voltage (U): 230V-(1P, 1P+N), 400V-(2P-4P, 3P+N);
Rated insulation voltage (Ui): 500V;
Frequency: 50Hz
Electromagnetic tripping ...
|
|
CHINT/CHINT YBLX-ME series travel switch
YBLX-ME series travel switch is suitable for AC 50Hz or 60Hz, voltage 380V, DC voltage 220V control circuit, for the travel control of the moving mechanism, the change of the direction or speed of the movement, the automatic control of the machine tool, the limit action of the moving mechanism and the control of the stroke or program.
Symbol...
|
|
CHINT/CHINT NL1-63 residual current action circuit breaker
NL1-63 residual current action circuit breaker (without overcurrent protection) is suitable for AC 50Hz, rated voltage at two poles 230V, four poles 400V, rated current to 63A line, when the person is electrocuted or the leakage current of the power grid exceeds the specified value, the residual current action circuit breaker can be used in a very short time ...
|
|
CHINT/CHINT DZ20 Series Plastic Case Circuit Breaker DZ20C-160
DZ20 series plastic shell circuit breaker (hereinafter referred to as circuit breaker), its rated insulation voltage is 660V, AC 50Hz, rated working voltage 380V and below, and its rated current is from 32A to 1250A. Generally used for power distribution, the rated current of type C is 160A and below, and the shell of type 630 and below ...
|
|
CHINT/CHINT Miniature Circuit Breaker NXB-63H has a frequency of 50Hz
Introduction: CHINT/CHINT miniature circuit breaker NXB-63H is a new type of leakage circuit breaker integrating leakage relay, leakage circuit breaker, AC contactor, undervoltage and other functions. It can automatically distinguish between slowly variable leakage and abrupt leakage (electric shock) for protection
Product parameters
Forehead...
|
|
CHINT/CHINT NPM8 series metal button
NPM8 series push buttons are suitable for industrial control, instrumentation, and household appliances with AC 50Hz (60Hz), rated working voltage AC220V and below, or DC working voltage DC110V and below. It is used for the control of electrical circuits of contactors, relays and other signals, with an indication ...
|
|
CHINT/CHINT CJ40 Series AC Contactor CJ40-125
CJ40 series AC contactor (hereinafter referred to as contactor) is mainly used for switching and breaking circuits in power systems with AC 50Hz or 60Hz, rated voltage to 660V or 1140V, and current to 1000A.
|
|
CHINT/CHINT CKJ5 Series Vacuum AC Contactor CKJ5-400
CKJ5 series vacuum AC contactor (hereinafter referred to as contactor) is mainly used in AC 50Hz, rated working voltage to 1140V, rated working current to 630A circuit, for long-distance connection and breaking of circuits, and can be used with appropriate thermal overload relay or electronic protection ...
|
|
CHINT/CHINT CJ19 Series Switching Capacitor Contactor CJ19-43
CJ19 series switching capacitor contactor (hereinafter referred to as contactor) is mainly used in power lines with AC 50Hz (or 60Hz) and rated working voltage to 690V, which is used for low-voltage reactive power compensation equipment to put in or remove low-voltage shunt capacitors. Contactors with inhibition ...
|
|
CHINT/CHINT NB5LE residual current action circuit breaker
CHINT Xinrui NB5LE series terminal power distribution products are suitable for AC 50Hz, rated voltage 230V/400V, rated current to 125A in commercial buildings, residential buildings, industrial equipment and similar places of power line facilities and electrical equipment, with overload protection, short circuit protection, residual ...
|
|
CHINT/CHINT Power Distribution Appliance NA8 Series Universal Circuit Breaker
Product Overview
NA8 series universal circuit breaker rated working current from 200A to 7500A, rated limit short-circuit breaking capacity up to 150kA, rated working voltage up to AC1140V, ambient temperature of -45 °C-+70°C, NA8 series universal circuit breaker set height ...
|
|
CHINT/CHINT uninterruptible power supply PC-UPS series The input frequency is 50/60HZ
Introduction: PC-UPS series uninterruptible power supply is a backup UPS model specially developed for computer loads. It is mainly composed of charging module, battery pack, inverter module and conversion device and other modules, when the mains is normal, it provides a straight-through mains or tap transformer to the load and slightly stabilized the voltage.
|
|
CHINT/CHINT NSD1 series servo drives
Servo drives, also known as "servo controllers" and "servo amplifiers", are a kind of controller used to control servo motors, and their functions are similar to those of inverters acting on ordinary AC motors. Servo drives are part of the servo system and are mainly used in high-precision ...
|
|
CHINT/CHINT CJ20 Series AC Contactor CJ20-10
CJ20 series AC contactor (hereinafter referred to as contactor) is mainly used in AC 50Hz (or 60Hz), rated working voltage to 660V, rated working current to 630A, for long-distance switching and breaking circuits, and can be combined with appropriate thermal overload relays.
|
|
CHINT/CHINT NCH8G Household AC Contactor NCH8G-25/10
NCH8G series household AC contactor (hereinafter referred to as contactor) is mainly suitable for AC 50Hz (or 60Hz), rated working voltage to 400V rated working current to 63A circuit, control household appliances and similar uses of low-inductance and micro-inductance loads; It can also be used to control household ...
|
|