NXRC series contactor relays are mainly used in relay control, signal transmission, isolation amplification and other circuits with AC 50Hz or 60Hz, rated working voltage to 380V and DC rated voltage to 220V, for switching, breaking and amplifying.
● Comply with standards: GB/T 14048.5, IEC/EN60947-5-1.
This article introduces CHINT/CHINT NXRC series contactor relay products if you are interested, please also contact our customer service, we are looking forward to your call, hope our technology and service can bring you a better experience.
The company has been customer-centric, the concept of creating value for customers, winning the market with quality and service, and sincerely hopes to cooperate with all sectors of society to create success, create brilliance together, and work together to create a better tomorrow! In line with the concept of credibility and service-oriented, the company warmly welcomes new and old customers to inquire, visit and negotiate business!
|
More on that
|
CHINT/CHINT HY23 Series Reverse Switch HY23-131
HY23 series instead of HZ3 series combination switch is suitable for AC 50Hz or 60Hz, voltage 380V circuit, as a power supply introduction switch, or as a three-phase squirrel cage induction motor with a control operation frequency of no more than 300 times per hour.
Rated voltage: 380
Rated current: 30
Control Electricity ...
|
|
CHINT/CHINT Single Magnetic Circuit Breaker NB8-63M
Introduction: CHINT/CHINT Miniature Circuit Breaker NXB-40 is a new type of leakage circuit breaker integrating leakage relay, leakage circuit breaker, AC contactor, undervoltage and other functions. It can automatically distinguish between slowly variable leakage and abrupt leakage (electric shock) for protection
Product parameters
Forehead...
|
|
CHINT/CHINT Terminal Block-JCUK Series
JCUK series is suitable for wire connection in circuits with AC 50Hz or 60Hz, rated voltage to 1000V and rated cross-sectional area to 150mm2. It is installed on TH35 rails.
Comply with standards: GB/T 14048.7, IEC 60947-7-1.
This article introduces the CHINT/CHINT Terminal Blocks - ...
|
|
CHINT/CHINT YBLX-HL series travel switch YBLX-HL/5030
YBLX-HL travel switch is mainly used in the control circuit of AC 50Hz or 60Hz, voltage 380V, DC voltage 220V, for the travel control of the moving mechanism, the transformation of the direction or speed of the movement, the automatic control of the machine tool, the limit action of the moving mechanism and the control of the stroke or program.
Comply with the standard ...
|
|
CHINT/CHINT NCH8G Household AC Contactor NCH8G-20/20
NCH8G series household AC contactor (hereinafter referred to as contactor) is mainly suitable for AC 50Hz (or 60Hz), rated working voltage to 400V rated working current to 63A circuit, control household appliances and similar uses of low-inductance and micro-inductance loads; It can also be used to control household ...
|
|
CHINT NBHLE-32 residual current action circuit breaker
NBHLE-32 residual current action circuit breaker is suitable for AC 50Hz, rated voltage 230V/400V, rated current to 32A in the line, play the role of overload, short circuit and leakage protection, can also be used as infrequent on-off of the line under normal circumstances.
The product conforms to IEC61009-1, GB/T...
|
|
CHINT/CHINT CJX1 Series AC Contactor Quota insulation voltage 660V
Introduction: CHINT/CHINT AC contactor CJX1-9 is mainly used for AC 50Hz or 60Hz, the rated insulation voltage is 660V-1000V, and the rated working current is 9A-475A when the rated working voltage is 380V under the AC-3 use category, and is suitable for controlling AC electric ...
|
|
CHINT/CHINT NXBLE-125 residual current action circuit breaker
CHINT/CHINT NXBLE-125 residual current action circuit breaker
Rated current (In): 63A, 80A, 100A, 125A (1P+N, 2P);
Rated Residual Operating Current (IOn) : AC type: 0.03A, 0.05A, 0.075A, 0.1A, 0.3A; Type A: 0.03A, ...
|
|
CHINT/CHINT Ex9PL series signal lights and buzzers
The Ex9PL series indicator and buzzer board has a front height of 8mm, a curved surface design, and indicators of various voltage levels to meet various applications.
The light-emitting module adopts LED, which has high brightness, low energy consumption and long life. The lamp head protection grade is IP65, which is suitable for harsh environments. The buzzer has a continuous ...
|
|
CHINT/CHINT CJ20 Series AC Contactor CJ20-16
CJ20 series AC contactor (hereinafter referred to as contactor) is mainly used in AC 50Hz (or 60Hz), rated working voltage to 660V, rated working current to 630A, for long-distance switching and breaking circuits, and can be combined with appropriate thermal overload relays.
|
|
CHINT/CHINT NB8-63H miniature circuit breaker
NB8-63H miniature circuit breaker is mainly suitable for AC 50Hz, rated voltage to 415V, rated current to 63A in commercial office buildings, residential and general industrial terminal distribution lines, to provide overload, short circuit protection for the line, but also under normal circumstances for the line infrequent turnover...
|
|
CHINT/CHINT NC5 series AC contactors
The NC5 series AC contactors are primarily used at AC 50Hz (or 60Hz) and are rated for operating voltage up to 690V at AC-3/400(380)V
Circuits rated up to 630A in the use category for long-distance switching on and off circuits, and with appropriate thermal overload relays...
|
|
CHINT/CHINT S9 shunt tripper
The S9 shunt trip device (hereinafter referred to as the tripper) is mainly used for matching with NB1 or NBH8 series circuit breakers, and is suitable for long-distance shunt tripping operation in lines with AC 50Hz (or 60Hz) rated voltage to 400V.
Meets the standard: IEC60947-5-1, obtained CE certification.
3.1 Basic ...
|
|
CHINT/CHINT NU5 surge protector
NU5-I.+II. surge protective devices comply with GB/T 18802.11. It is suitable for AC 50Hz, rated voltage of single-phase 230V/ three-phase 400V power distribution and control system, meets SPD level I and II tests, and is used to suppress transient overvoltage lower than the equipment impulse resistance overvoltage, venting ...
|
|
CHINT/CHINT NCH8G Household AC Contactor NCH8G-20/02
NCH8G series household AC contactor (hereinafter referred to as contactor) is mainly suitable for AC 50Hz (or 60Hz), rated working voltage to 400V rated working current to 63A circuit, control household appliances and similar uses of low-inductance and micro-inductance loads; It can also be used to control household ...
|
|
CHINT/CHINT Terminal Appliances —NXU-III. Surge Protective Device
CHINT/CHINT Terminal Appliances —NXU-III. Surge Protective Device
Basic parameters and technical performance indicators (Table 1)
Design types and protection mode combinations for different models of surge protective devices (see Table 2)
SPECIAL FEATURES
The surge protective device has a deterioration indication, as shown in sequence 3 in the figure ...
|
|
CHINT/CHINT NVF5 series inverter No PG vector
Introduction: NVF5 series simple vector inverter, using no speed sensor vector control technology, has the characteristics of small and lightweight, fast operation and excellent performance.
Product parameters
input
Voltage range: single-phase 230V (±15%) three-phase 380V (-15%) - 4 ...
|
|
CHINT/CHINT NKZ1 universal transfer switch
NKZ1-20 series universal transfer switch can be used in AC 50Hz or 60Hz, voltage 415V and below, DC voltage 220V and below circuits for conversion of electrical control circuits and electrical measuring instruments, such as: electromagnetic coils, electrical measuring instruments, capacitor cabinets, etc., can also be used for direct control ...
|
|
CHINT/CHINT NSC1 series motion controller
1.1 32-bit high-performance CPU, compiled execution mode, scan cycle 10 times faster than analytical type, basic instruction single-step running time of 0.05μs.
1.2 Support USB power supply to download the program and debug.
1.3 2 communication ports, 1 RS232, 1 RS485.
1.4 High Reliability USB Download, Monitor, ...
|
|
CHINT/CHINT NSC1 Series Motion Controller NSC1-D8T
32-bit high-performance CPU, compiled execution mode, scan cycle is 10 times faster than analytical type, and the basic instruction single-step running time is 0.05μs.
Weight: 102
Power consumption: 2
Digital inputs: 8
Output voltage: 6-30VDC
Maximum inductive load: 12W
Maximum Resistance Load: Single-point maximum ...
|
|