NL1-63 residual current action circuit breaker (without overcurrent protection) is suitable for AC 50Hz, rated voltage at two poles 230V, four poles 400V, rated current to 63A line, when the person is electrocuted or the leakage current of the power grid exceeds the specified value, the residual current action circuit breaker can quickly cut off the fault power supply in a very short time, protect the safety of people and electrical equipment, and can also be used as an infrequent conversion start of the line.
The products are suitable for various places such as industrial, commercial, high-rise and residential buildings.
Comply with standards: GB/T 16916.1, IEC 61008-1, and obtain CCC, SEMKO, CE, RCC, EAC and Ukraine certifications.
Main parameters and technical performance
Technical parameters item | Parameter value | Rated voltage (Ue) | 230V AC(1P+N) , 400V AC(3P+N) | Rated current (In) | 25A、40A、 63A | Rated insulation voltage (Ui) | 500V | Rated impulse withstand voltage (Uimp) | 4kV | Rated residual operating current(△N) | 0.03A , 0.1A.0.3A | Number of poles | 1P+N、3P+N | According to the working condition when there is a DC component | AC type | Rated Limit Short-Circuit Current (m) | 6000A | Rated Limit Residual Short-Circuit Current (I△m) | 6000A | Rated Switching and Breaking Capacity (Inc) | 500A(In=25 , 40A) ; 630A(In= 63A) | Rated residual on- and breaking capacity (△c) | 500A(n=25 , 40A) ; 630A(In= 63A) | Rated residual inactive current | 0.5I△n | This article introduces CHINT/CHINT NL1-63 residual current action circuit breaker if you are interested, please also contact our customer service, we are looking forward to your call, hope our technology and service can bring you a better experience.
The company has been customer-centric, the concept of creating value for customers, winning the market with quality and service, and sincerely hopes to cooperate with all sectors of society to create success, create brilliance together, and work together to create a better tomorrow! In line with the concept of credibility and service-oriented, the company warmly welcomes new and old customers to inquire, visit and negotiate business!
|
More on that
|
CHINT/CHINT AX-X3H auxiliary contact
The AX-X3H auxiliary contact complies with GB/T 14048.5 standard. It is mainly used in lines with AC rated voltage up to 415V or DC rated voltage up to 130V. Signal indication of long-distance circuit breaker when assembled with NBH-125 series circuit breaker.
The auxiliary contact is an accessory product that is assembled in the open circuit ...
|
|
CHINT/CHINT Terminal Appliances —NU6-II Series Surge Protector
NU6-II. series surge protector is suitable for AC 50Hz, rated voltage of single-phase 230V/three-phase 400V power distribution and control system, to meet the SPDII. level test, used to suppress the transient overvoltage below the equipment withstand impulse overvoltage, discharge surge energy, so as to protect the system circuit and equipment.
Suitable...
|
|
CHINT/CHINT NB1L (10kA) residual current operated circuit breaker
NB1L residual current action circuit breaker is suitable for AC 50Hz, rated voltage 230V, rated current to 40A line, when the person is electrocuted or the leakage current of the power grid exceeds the specified value, the residual current action circuit breaker can quickly cut off the fault power supply in a very short time, protect people and electrical equipment...
|
|
CHINT/CHINT NBH-80 miniature circuit breaker
NBH-80 miniature circuit breaker is suitable for AC 50Hz, rated voltage 230V, rated current 80A in household and similar places of the line, for overload and short circuit protection, under normal circumstances, as the line of infrequent operation and conversion, can also be used as a disconnected line for line and equipment maintenance...
|
|
CHINT OUVT-X3H over/undervoltage tripper
OUVT-X3H over-under-voltage tripper is suitable for AC 50Hz, rated voltage 230V line, and NBH-125 series circuit breaker with the use of NBH-125 series circuit breaker, when the terminal voltage of the tripper is reduced to the under-voltage protection range or increased to the over-voltage protection range, the tripper acts and drives the circuit breaker to automatically break, ...
|
|
CHINT/CHINT CKJ5 Series Vacuum AC Contactor CKJ5-125
CKJ5 series vacuum AC contactor (hereinafter referred to as contactor) is mainly used in AC 50Hz, rated working voltage to 1140V, rated working current to 630A circuit, for long-distance connection and breaking of circuits, and can be used with appropriate thermal overload relay or electronic protection ...
|
|
CHINT NB3LE-63M residual current action circuit breaker
This product is suitable for AC 50Hz, rated voltage 230V, rated current to 63A line, play overload, short circuit and leakage protection, can also be used as infrequent line on/off under normal circumstances.
Conform to the standard: GB/T 16917.1 IEC 61009-1, obtained CCC certification...
|
|
CHINT/CHINT Terminal Appliance —NHH-125 Disconnector
NHH-125 disconnector is suitable for AC 50Hz, rated voltage 230V/400V, rated current to 125A in the power distribution and control circuit, mainly as the main switch in the terminal combination appliances, can also be used to control all kinds of low-power electrical appliances and lighting, can be widely used in commercial and home and other places. ...
|
|
CHINT/CHINT Plastic Case Circuit Breaker NXB-125 Insulation voltage 500V
Introduction: CHINT/CHINT Plastic Housing Circuit Breaker NXB-125 is a new type of leakage circuit breaker integrating leakage relay, leakage circuit breaker, AC contactor, undervoltage and other functions. It can automatically distinguish between slowly variable leakage and abrupt leakage (electric shock) for protection
Product parameters
...
|
|
CHINT/CHINT Energy Meter DTSY666 220/380V5(20)A
DTSY666 type three-phase four-wire electronic prepaid electric energy meter (hereinafter referred to as electric energy meter) can realize the functions of electric energy metering, electricity pre-purchase, * large load limit, etc., the product is the ideal electric energy metering product for electricity charging reform, improve the level of scientific management of power supply, and promote electricity consumption.
Features ...
|
|
CHINT/CHINT NKZ1 universal transfer switch
NKZ1-20 series universal transfer switch can be used in AC 50Hz or 60Hz, voltage 415V and below, DC voltage 220V and below circuits for conversion of electrical control circuits and electrical measuring instruments, such as: electromagnetic coils, electrical measuring instruments, capacitor cabinets, etc., can also be used for direct control ...
|
|
CHINT/CHINT switch NXZ series rated insulation voltage AC800v
Introduction: NXZ series automatic transfer switch electrical appliances are suitable for AC 50Hz, rated voltage 400V/415V and below, rated current to 630A three-phase four-wire dual-circuit power supply grid, automatically connect one or several load circuits from one power supply to another, in order to ensure the normal supply of load circuits.
|
|
CHINT/CHINT NCH8G Household AC Contactor NCH8G-40/40
NCH8G series household AC contactor (hereinafter referred to as contactor) is mainly suitable for AC 50Hz (or 60Hz), rated working voltage to 400V rated working current to 63A circuit, control household appliances and similar uses of low-inductance and micro-inductance loads; It can also be used to control household ...
|
|
CHINT/CHINT HY23 Series Reverse Switch HY23-131
HY23 series instead of HZ3 series combination switch is suitable for AC 50Hz or 60Hz, voltage 380V circuit, as a power supply introduction switch, or as a three-phase squirrel cage induction motor with a control operation frequency of no more than 300 times per hour.
Rated voltage: 380
Rated current: 30
Control Electricity ...
|
|
CHINT/CHINT NVF5 series inverter No PG vector
Introduction: NVF5 series simple vector inverter, using no speed sensor vector control technology, has the characteristics of small and lightweight, fast operation and excellent performance.
Product parameters
input
Voltage range: single-phase 230V (±15%) three-phase 380V (-15%) - 4 ...
|
|
CHINT/CHINT YBLX-WL Series Position Switch YBLX-WL/NJ
YBLX-WL travel switch is mainly used in the control circuit of AC 50Hz or 60Hz, voltage 380V, DC voltage 220V, for the travel control of the moving mechanism, the transformation of the direction or speed of the movement, the automatic control of the machine tool, the limit action of the moving mechanism and the control of the stroke or program.
Accord with...
|
|
CHINT/CHINT NXBF-125 plastic case circuit breaker
NXBF-125 plastic shell circuit breaker is suitable for AC 50Hz, rated voltage 230V/400V, rated current to 125A in the line, for overload and short circuit protection, under normal circumstances, as the line of infrequent operation and conversion, can also be used as a disconnection line for line and equipment maintenance...
|
|
CHINT/CHINT Terminal Appliances —NXU-III. Surge Protective Device
CHINT/CHINT Terminal Appliances —NXU-III. Surge Protective Device
Basic parameters and technical performance indicators (Table 1)
Design types and protection mode combinations for different models of surge protective devices (see Table 2)
SPECIAL FEATURES
The surge protective device has a deterioration indication, as shown in sequence 3 in the figure ...
|
|
CHINT/CHINT Miniature Circuit Breaker NB8-63 rated frequency 50Hz
Introduction: CHINT/CHINT miniature circuit breaker NB8-63 miniature circuit breaker is mainly suitable for AC 50Hz, rated current to 63A in commercial office buildings, residential and general industrial terminal distribution lines, to provide overload, short circuit protection for the line, but also under normal circumstances...
|
|
CHINT/CHINT Miniature Circuit Breaker NXB-80 withstand voltage 4kV
Introduction: CHINT/CHINT miniature circuit breaker NXB-125G is a new type of leakage circuit breaker integrating leakage relay, leakage circuit breaker, AC contactor, undervoltage and other functions. It can automatically distinguish between slowly variable leakage and abrupt leakage (electric shock) for protection
Product parameters
...
|
|