Description: Designed to detect ultra-low NOx emissions in industrial and commercial combustion, the Rosemount/Rosemount Continuous Gas Analyzer XECLD uses highly stable, solid-state chemiluminescence detection (CLD) technology to help operators demonstrate compliance with environmental regulations. XECLD's best-in-class reliability and worry-free maintenance design eliminates the need for vacuum pumps, reducing sources of vibration that can compromise equipment integrity and measurement reliability.
Features:
The user-selectable NOx measurement range is very wide, from 0 - 5 ppm to 10,000 ppm.
Not only for NOx emission monitoring in industrial combustion applications, but also for vehicle emissions and engine testing, as well as purity measurement in medical and food and beverage applications.
Thermoelectrically cooled, solid-state detector assemblies ensure reliable performance and longer operating life.
The integrated web interface enables analyzer configuration and monitoring without the need to install additional software.
Advanced diagnostics enhance visibility into analyzer health and process conditions, and provide operational information to improve reliability and efficiency.
With a friendly, intuitive local operator interface (LOI), the analyzer can be operated without the need for a computer or handheld communicator.
Reliable NOx emissions monitoring is designed to comply with United States EPA Method 7E procedures as well as the European standard EN 14792:2017.
Featuring the proven chemiluminescence detection technology pioneered by Emerson Beckman, which continues to dominate as the industry-standard reference method for measuring nitrogen oxides (NOx).
Product parameters
Measurement range: 0 - 5 ppm to 10,000 ppm
Detection limit: ≤ 1% FS
Reproducibility: ≤ 0.5% FS
Linearity: ≤ 1% FS
Ambient Temperature: Storage: -4 - 158 °F (-20 - 70 °C)
Operating: 41 - 104 °F (5 - 40 °C). Leave 1 HU (1.75 in./44.5 mm) between the analyzer and other equipment in the cabinet.
Analog inputs: 2 analog inputs: 0-1(10) V (Rin - 100 kΩ) or 4 (0)-20mA (Rin - 50 Ω)
Analog outputs: 1 or 2, individually and optically isolated
4 (0)-20 mA (RB ≤ 500 Ω)
1 is the standard and 2 is the option
Our customer-centric service concept: the pursuit of a full range of services is a high-quality, high-standard service, the pursuit of every detail of the service process. It is impossible for interests to blossom into brilliant flowers from lies. Only every process, every action, and every detail of the service can be professional and careful, in order to meet or even exceed customer expectations, so that customers are satisfied and recognize us. Honest, professional, affordable, fast, so let you rest assured." Integrity and professional service, affordable price, and continuous improvement" is our service concept.
This article introduces the Rosemount/Rosemount Continuous Gas Analyzer XECLD products, if you are interested in the Rosemount/Rosemount Continuous Gas Analyzer, please also contact our customer service, we look forward to your call, hope our technology and service can bring you a better experience.
|
More on that
|
Rosemount/Rosemount RTD Temperature Sensor 65
Introduction: The Rosemount/Rosemount RTD Temperature Sensor 65, an industry-standard PT-100 RTD sensor, is a single-element or two-element device designed in accordance with the IEC 751 standard to cover ...
|
|
Rosemount/Rosemount Primary Sonic Gas Ultrasonic Flowmeter USM341220
Introduction: Rosemount/Rosemount primary sonic gas ultrasonic flowmeters are USM341220 for non-legal-for-trade metering of natural gas, such as verification metering, pipeline balancing, storage measurement, production or moisture metering. Featuring Mark III electronics and two-channel measurement redundancy.
...
|
|
Rosemount/Rosemount Electromagnetic Sensor MS060 Accuracy±0.25%
Introduction: The Rosemount/Rosemount electromagnetic sensor MS060, MS slurry sensor is a reliable solution for difficult-to-measure applications such as grit, high solids fluids, long fiber slurries, or installations that generate excessive process noise. The MS slurry sensor is designed for difficult-to-measure...
|
|
Rosemount/Rosemount Sensor 8721 Caliber 1/2-4 inch
Description: The Rosemount/Rosemount Sensor 8721 features a fully welded instrument body and is specifically designed for safe, hygienic and reliable performance in food, beverage and life sciences applications. All contact surfaces are manufactured using FDA-approved materials and are designed to meet 3A and EHEDG standards.
|
|
Rosemount/Rosemount 148 Temperature Transmitter 4-20mA Simulation
Summary: The Rosemount 148 temperature transmitter is a standard unit that can be used with a variety of sensor type inputs and can be cost-effectively installed with higher measurement accuracy than direct-wire solutions. The transmitter is available in a DIN B top-mount configuration and has a ...
|
|
Rosemount/Rosemount Carbon Monoxide Analyzer CCO 5500
Introduction: The Rosemount/Rosemount Carbon Monoxide Analyzer CCO 5500, the CCO 5500 Carbon Monoxide (CO) Analyzer uses infrared absorption spectroscopy to continuously measure the concentration of carbon monoxide in combustion flue gases. The infrared source is mounted directly on the flue gas duct or chimney on the opposite side of the receiver. Infrared...
|
|
Rosemount/Rosemount Electromagnetic Flowmeter Sensor 8721020 Tubing Size 15-100mm
Description: Rosemount/Rosemount electromagnetic flowmeter sensor 8721020 designed for food, beverage, and life science applications. All contact surfaces are manufactured using FDA-approved materials and are designed to meet 3A and EHEDG standards.
Features:
Lightweight and compact ...
|
|
Rosemount Flanged Electromagnetic Flowmeter Sensor 8705020 15-900mm diameter
Introduction: The Rosemount/Rosemount flanged electromagnetic flowmeter sensor 8705020 all-welded construction provides an airtight port for moisture and contaminant protection, while the junction box is removable and replaceable for easy field service.
Features:
For added protection, equipped with ...
|
|
Rosemount/Rosemount Hygienic Flow-Through Toroidal Conductivity Sensor 245
Introduction: The Rosemount/Rosemount Hygienic Flow-Through Toroidal Conductivity Sensor 245 is a non-intrusive flow design that can be installed in-tube without blocking the sample flow path. These sensors are suitable for viscous, abrasive or fibrous liquids and are designed to be used in ...
|
|
Rosemount/Rosemount Power Locator Hagan Repeatability 1.0%
Introduction: Rosemount/Rosemount Power Locator Hagan, the industry needs a powerful force to accurately control process valves, dampers, and feed mechanisms and react to demand signals. Emerson's Rosemount Analytical Pneumatic Power Positioners consistently meet these demanding control requirements, with ...
|
|
Rosemount Electromagnetic Flowmeter Sensor 8711015 4-200mm
Description: The Rosemount/Rosemount Electromagnetic Flowmeter Sensor 8711015 and offers a compact, lightweight alternative to flanged magnetic flowmeters. Alignment gasket kit for easy installation.
Features:
Flange structure, size and weight are the most ...
|
|
Rosemount/Rosemount Transmitter 702 Update time 1 second to 60 minutes
Introduction: The Rosemount/Rosemount Transmitter 702 Plunger in Place Detection Discrete Transmitter uses a plunger to improve the efficiency of natural gas well sites. The transmitter is used in conjunction with an existing plunger position sensor to detect a position event and send back a wireless signal.
Features:
Designed for ...
|
|
Rosemount/Rosemount Ultrasonic Flow Meter USM341810
Introduction: Rosemount/Rosemount Ultrasonic Flow Meter USM341810, the new Rosemount 3418 Octal Ultrasonic Flow Meter is manufactured, developed, and engineered by Emerson to deliver high accuracy and best-in-class performance with the high functionality required by precision legal-for-trade users. 3418 Flow Meter ...
|
|
Rosemount/Rosemount Open Circuit Toxic Gas Detector 936 Power 24VDC
Introduction: Rosemount/Rosemount Open Path Toxic Gas Detector 936, The Rosemount 936 Open Path Toxic Gas Detector provides high performance against hydrogen sulfide (H2S) and ammonia (NH3) even in harsh environments where dust, fog, rain, ice, ice, or vibration can cause significant signal attenuation.
|
|
Rosemount/Rosemount Tank Radar Level Gauge TGU 65 Baseline Accuracy ±2mm
Introduction: The Rosemount/Rosemount Tank Radar Level Gauge TGU 65 provides the performance needed to obtain accurate draft and level readings for narrow sludge tanks. The Rosemount TGU 65 Tank Radar Level Gauge is designed for long-term performance in harsh conditions. 10 GHz FMCW Array ...
|
|
The Rosemount/Rosemount Transmitter 2090P has a 20:1 turndown ratio
Introduction: The Rosemount/Rosemount Transmitter 2090P Pulp & Paper Pressure Transmitter is ideal for the pulp and paper industry due to its compact size and rugged construction. This lightweight transmitter is available with a 1in. Flush mounting connections, or ...
|
|
Rosemount/Rosemount Continuous Gas Analyzer CT5800 Weight 85kg
Introduction: Rosemount/Rosemount Continuous Gas Analyzer CT5800, Emerson's Rosemount CT5800 Continuous Gas Analyzer is the first quantum cascade laser designed specifically for industrial process applications requiring Class I, Class 2 hazardous area certification. The CT5800 in a fireproof enclosure has ...
|
|
Rosemount/Rosemount Clamp-on Electromagnetic Flowmeter Sensor 8711040
Introduction: The Rosemount/Rosemount Clip-on Electromagnetic Flowmeter sensor 8711040 provides a compact, lightweight alternative to flanged magnetic flowmeters. Alignment gasket kit for easy installation.
Features:
Flange structure, dimensions and ...
|
|
Rosemount/Rosemount Slurry Electromagnetic Flowmeter Sensor 8707300 Power Supply 115VAC
Description: The Rosemount/Rosemount Slurry Electromagnetic Flowmeter Sensor 8707300 provides enhanced signal strength along with advanced signal processing and superior filtering technology for flow metering stability in the most difficult, noisy slurry applications.
Features:
...
|
|
Rosemount Dissolved Oxygen Sensor 499ADO Size 7.6m
Introduction: The Rosemount/Rosemount Dissolved Oxygen Sensor Model 499ADO, Model 499ADO is a diaphragm-covered current sensor that continuously measures dissolved oxygen between 0 and 20 ppm. The main application of this product is wastewater aeration tank.
Features:
...
|
|