Introduction: The Rosemount/Rosemount Tank Radar Level Gauge TGU 65 provides the performance needed to obtain accurate draft and level readings for narrow sludge tanks. The Rosemount TGU 65 Tank Radar Level Gauge is designed for long-term performance in harsh conditions. The 10 GHz FMCW array antenna is mounted on a waveguide tube and is resistant to deposits in the duct in a low-consumption mode. This unit is suitable for optional redundant level or independent high level measurement.
Features:
High measurement accuracy and reliability, suitable for use in harsh tank and deck conditions.
10 GHz FMCW Tank Radar Level Gauge with Hydrostatic Pipeline Antenna in Low Consumption Mode to Withstand Deposits in Pipes.
Ideal solution for level measurement in narrow tanks or seawater draft applications.
Easy to install, shallow tank insertion, small deck footprint.
Suitable for optional redundant level or stand-alone high level measurement.
The marine version TGU 65C with a measuring range of 35 m and the offshore version TGU 65S with a measuring range of up to 65 m are available.
The design and enclosure are rugged and suitable for working in harsh marine conditions.
Product parameters
Operating temperature: -40 to +100°C
Reference accuracy: ± 2 mm
Weight: 17kg
Enclosure rating: IP66/67
Process Connectors: Suitable for installation in JIS 5K-200, DN200, ASME 8"
Housing material: stainless steel 316L, PTFE, fluorosilicone
Explosion proof: Ex ia IIC T4 Ga
Our customer-centric service concept: the pursuit of a full range of services is a high-quality, high-standard service, the pursuit of every detail of the service process. It is impossible for interests to blossom into brilliant flowers from lies. Only every process, every action, and every detail of the service can be professional and careful, in order to meet or even exceed customer expectations, so that customers are satisfied and recognize us. Honest, professional, affordable, fast, so let you rest assured." Integrity and professional service, affordable price, and continuous improvement" is our service concept.
This article introduces the Rosemount/Rosemount Tank Radar Level Gauge TGU 65 product, if you are interested in Rosemount/Rosemount Tank Radar Level Gauge, please also contact our customer service, we look forward to your call, hope our technology and service can bring you a better experience.
|
More on that
|
The Rosemount/Rosemount Flow Meter 2051CFC has a 100:1 turndown ratio
Description: The Rosemount/Rosemount Flow Meter 2051CFC, the Rosemount 2051CFC Wireless Compact Annubar Flow Meter uses secure WirelessHART® technology to deliver industry-standard performance with >99% data reliability. The device has a machine mounted on a convex ...
|
|
The Rosemount/Rosemount Transmitter 3051S MultiVariable™ has a 200:1 turndown ratio
Description: The Rosemount/Rosemount Transmitter 3051S MultiVariable™, a single device of a multivariable transmitter that measures differential pressure, static pressure, and process temperature. This multivariable transmitter is a cost-effective solution to reduce pipe penetrations, impulse pipes, and connection systems ...
|
|
Rosemount Flanged Vortex Flow Meter 8800DD120
Description: The Rosemount/Rosemount Flanged Vortex Flow Meter 8800DD120 features redundant, independent sensors and electronics to help avoid false starts. Suitable for safety interlock systems and related applications.
Features:
The isolated sensor design allows for a process without destroying the process code.
|
|
Rosemount/Rosemount vortex flowmeter 8600DF030 outputs 4-20mA
Description: The Rosemount/Rosemount Vortex Flow Meter 8600DF030 product is optimized and cost-effective for general flow metering as well as clean fluid applications including steam, air, water, and nitrogen.
Features:
No moving parts, no repairs and maintenance ...
|
|
Rosemount/Rosemount Slurry Electromagnetic Flowmeter Sensor 8707100 consumes up to 300W
Description: The Rosemount/Rosemount Slurry Electromagnetic Flowmeter Sensor 8707100 provides enhanced signal strength along with advanced signal processing and superior filtering technology for flow metering stability in the most difficult, noisy slurry applications.
Features:
...
|
|
Rosemount/Rosemount Wireless Integrated Orifice Flowmeter 3051CFP tubing sizes range from 15 to 40mm
Description: The Rosemount/Rosemount Wireless All-in-One Orifice Flow Meter 3051CFP, with the Rosemount 3051CFP Wireless All-in-One Orifice Flow Meter, there are no wiring costs and industry-leading accurate flow measurement through the WirelessHART® protocol. By Ann ...
|
|
Rosemount/Rosemount Slurry Electromagnetic Flowmeter Sensor 8707360
Introduction: Rosemount/Rosemount Slurry Electromagnetic Flowmeter Sensor 8707360 In the most difficult, noisy slurry applications, enhanced signal strength, along with advanced signal processing and superior filtration technology, contribute to the stability of flow metering.
Features:
...
|
|
Rosemount/Rosemount Level Transmitter 1408H 116 psi working pressure
Introduction: Rosemount/Rosemount Level Transmitter 1408H, Rosemount 1408H Level Transmitter provides accurate continuous level measurement. The radar is specifically designed to meet the hygienic requirements of the food and beverage industry. Hygienic approvals (3-A®, FDA, EC 1935/2004, ...)
|
|
Rosemount/Rosemount Retractable pH/ORP Sensor 398R
Introduction: The Rosemount/Rosemount Retractable pH/ORP Sensor 398R, the Rosemount 398R, with its Tefzel™ and titanium chemically resistant construction and patented TUpH™ reference junction, make it an ideal sensor for measuring the pH of demanding process liquids. ...
|
|
Rosemount/Rosemount Liquid Ultrasonic Flow Meter USM381424 Pressure range 0 to 155 Bar
Description: The Rosemount/Rosemount Liquid Ultrasonic Flow Meter USM381424, a new custody transfer meter with excellent linearity over the flow range to further reduce product loss and unidentified loss. A new generation of electronics optimizes the operation of the flow meter, and the full-bore design ensures that the flow meter is ...
|
|
The Rosemount/Rosemount Fixed Gas Detection Transmitter 925 outputs 4-20mA
Introduction: Rosemount/Rosemount Fixed Gas Detection Transmitter 925, Designed for use with the Rosemount 625 gas sensor, the Rosemount 925 Fixed Gas Detection Transmitter has received global certifications for the latest hazardous area and performance standards.
Features:
...
|
|
Rosemount/Rosemount Gas Sensor 625 Humidity Range 0-95%
Introduction: Rosemount/Rosemount Gas Sensor 625, Rosemount 625 Combustible Gas Sensor uses Non-Dispersive Infrared (NDIR) technology with excellent functionality and performance specifications. NDIR gas sensors detect gas leaks early, making workers safer and improving sustainability.
|
|
Rosemount/Rosemount 935 Open Path Combustible Gas Detector Power supply 24VDC nominal
Introduction: Rosemount/Rosemount 935 Open Path Combustible Gas Detector, The Rosemount 935 Open Path Detector provides continuous monitoring of hydrocarbon gases even in harsh environments where dust, fog, rain, ice, ice, or vibration can be a significant obstruction. The equipment adopts ...
|
|
Rosemount/Rosemount Sanitary Coriolis Meter H100S
Introduction: Rosemount Hygienic Coriolis Meter H100S, Coriolis Flow Meter made of 316L stainless steel, 3A/EHEDG certified, and finished up to 32Ra (0.8?m), is a hygienic application that requires high reliability, repeatability, and stable measurements.
|
|
Rosemount/Rosemount Electromagnetic Flowmeter Sensor 8721030 Tubing Sizes 15-100mm
Description: Rosemount/Rosemount electromagnetic flowmeter sensor 8721030 designed for food, beverage, and life sciences applications. All contact surfaces are manufactured using FDA-approved materials and are designed to meet 3A and EHEDG standards.
Features:
Lightweight and compact ...
|
|
Rosemount/Rosemount Flanged Vortex Flow Meter 8800DF080 Turndown ratio 38:01:00
Introduction: The Rosemount/Rosemount Flanged Vortex Flow Meter 8800DF080 eliminates potential leak points with a gasket-free, anti-clogging gauge body. Discrete sensors facilitate the replacement of flow and temperature sensors without damaging the process seal.
Features:
Isolated sensor design allows for ...
|
|
Rosemount/Rosemount Electromagnetic Sensor MS120 Pipe size 80-900mm
Introduction: The Rosemount/Rosemount electromagnetic sensor MS120, MS slurry sensor is a reliable solution for difficult-to-measure applications such as grit, high solids fluids, long fiber slurries, or installations that generate excessive process noise. The MS slurry sensor is designed for difficult-to-measure...
|
|
Rosemount/Rosemount Pressure Sensor MAS2600 Weight: 0.3kg
Introduction: The Rosemount/Rosemount pressure sensor MAS2600 uses MAS2600 pressure sensors to obtain accurate level and wind data for marine storage tanks. The sensor is designed to be mounted inside or outside the tank roof and sides, providing the flexibility to meet your needs ...
|
|
Rosemount/Rosemount Gas Analyzer CT4000 Size 23x19x45cm
Description: The Rosemount/Rosemount Gas Analyzer CT4000 uses built-in Quantum Cascade Laser (QCL) technology to monitor NO, NO2, SO2, CH4, H2O, CO, and CO at ambient temperatures up to 70°C (158°F) and 190°C (374°F) gas temperatures.
|
|
Rosemount/Rosemount Flow Meter 3051CFA Annubar™
Introduction: The Rosemount/Rosemount Flow Meter 3051CFA Annubar™, the Rosemount 3051CFA Annubar Flow Meter is an industry-leading flow measurement solution that uses a patented T-shaped average pitot tube to provide reliable accuracy across a wide flow range. Obtain...
|
|