DZ15 series plastic shell circuit breaker (hereinafter referred to as circuit breaker) is suitable for AC 50Hz, rated voltage of 380V, rated current to 100A circuit, as power distribution, motor overload and short circuit protection, but also as line infrequent conversion and motor infrequent start.
Rated voltage: 380
Rated current of shell frame grade: 40
Number of poles: 2/3 Rated current: 32.40
Rated very short circuit breaking capacity: 3
Rated operating short-circuit breaking capacity: 3
Arc distance: ≤50
This series of transparent shell circuit breakers is made of new, high-temperature-resistant, high-strength polycarbonate materials, which can intuitively judge the on-off state of the contacts, and are widely used in temporary power places in construction sites.
Comply with standards: GB/T 14048.2, IEC 60947-2.
This article introduces CHINT/CHINT DZ15 series plastic case circuit breaker DZ15-40 If you are interested, please also contact our customer service, we are looking forward to your call, and hope our technology and service can bring you a better experience.
The company has been customer-centric, the concept of creating value for customers, winning the market with quality and service, and sincerely hopes to cooperate with all sectors of society to create success, create brilliance together, and work together to create a better tomorrow! In line with the concept of credibility and service-oriented, the company warmly welcomes new and old customers to inquire, visit and negotiate business!
|
More on that
|
CHINT/CHINT Terminal Appliance —NU210-40 Surge Protector
NU210-40 is a surge protective device with short circuit protection. Connect to circuits and devices with an AC rated voltage of 230/400V, 50Hz. Able to protect terminal electrical equipment from the impact of induced lightning, it has the ability to protect against indirect lightning and direct lightning effects or other transient overvoltage surges.
|
|
CHINT/CHINT AX-X3H auxiliary contact
The AX-X3H auxiliary contact complies with GB/T 14048.5 standard. It is mainly used in lines with AC rated voltage up to 415V or DC rated voltage up to 130V. Signal indication of long-distance circuit breaker when assembled with NBH-125 series circuit breaker.
The auxiliary contact is an accessory product that is assembled in the open circuit ...
|
|
CHINT/CHINT NB5LE residual current action circuit breaker
CHINT Xinrui NB5LE series terminal power distribution products are suitable for AC 50Hz, rated voltage 230V/400V, rated current to 125A in commercial buildings, residential buildings, industrial equipment and similar places of power line facilities and electrical equipment, with overload protection, short circuit protection, residual ...
|
|
CHINT/CHINT NBH-80 miniature circuit breaker
NBH-80 miniature circuit breaker is suitable for AC 50Hz, rated voltage 230V, rated current 80A in household and similar places of the line, for overload and short circuit protection, under normal circumstances, as the line of infrequent operation and conversion, can also be used as a disconnected line for line and equipment maintenance...
|
|
CHINT/CHINT NCH8G Household AC Contactor NCH8G-63/20
NCH8G series household AC contactor (hereinafter referred to as contactor) is mainly suitable for AC 50Hz (or 60Hz), rated working voltage to 400V rated working current to 63A circuit, control household appliances and similar uses of low-inductance and micro-inductance loads; It can also be used to control household ...
|
|
CHINT DZ158LE-125□ Residual Current Operated Circuit Breaker
DZ158LE-125□ residual current action circuit breaker is suitable for AC 50Hz, rated voltage single pole two-wire, two-pole 230V, three-pole, three-pole four-wire, four-pole 400V rated current from 63A to 125A line, when the person is electrocuted or the leakage current of the power grid exceeds the specified value, the residual current action is broken.
|
|
CHINT/CHINT NB7LE series residual current action circuit breaker
NB7LE series residual current action circuit breaker is suitable for AC 50Hz, rated voltage single pole two wires, two poles 230V, three poles, three poles four wires, four poles 400V, rated current to 63A in the line, when the person is electrocuted or the leakage current of the power grid exceeds the specified value, the residual current action circuit breaker can be ...
|
|
CHINT/CHINT XF9J alarm auxiliary contact
XF9J alarm auxiliary contact is suitable for the line with the agreed heating current to 6A, AC rated voltage to 415V or DC rated voltage to 130V, and it is assembled with NB1 miniature circuit breaker or NB1L residual current action circuit breaker for signal indication of long-distance circuit breaker on/off.
Compliant with standards ...
|
|
CHINT/CHINT NTP1 Series Industrial Touch Screen NTP1-070E
Based on the Linux system, the system is stable, efficient and reliable. Industrial-grade high-performance Cortex A8 processor with a clock speed of 600MHz. The COM port integrates RS232/422/485 communication mode. The product provides USB master station and USB slave port, USB slave download port supports 10M/s transmission speed, ...
|
|
CHINT/CHINT NC7 Series AC Contactor Free air heating current 20A
Introduction: CHINT/CHINT AC contactor NC7-09 (hereinafter referred to as contactor) is mainly used for AC 50Hz (or 60Hz), rated working voltage to 690V, in the AC-3, 400V use category rated working current to 620A circuit, mainly used for long-distance connection and breaking circuits...
|
|
CHINT/CHINT Ex9ZA series universal transfer switch
The universal transfer switch is mainly suitable for AC 50Hz, rated working voltage 440V and below, DC voltage 240V and below electrical circuits, for manual infrequent connection or breaking of circuits.
It is mainly used for the conversion of various control lines, commutation measurement control of voltmeter and ammeter, and distribution.
|
|
CHINT/CHINT CKJ5 Series Vacuum AC Contactor CKJ5-125
CKJ5 series vacuum AC contactor (hereinafter referred to as contactor) is mainly used in AC 50Hz, rated working voltage to 1140V, rated working current to 630A circuit, for long-distance connection and breaking of circuits, and can be used with appropriate thermal overload relay or electronic protection ...
|
|
CHINT/CHINT NP2 series buttons
NP2 series button is suitable for AC 50Hz or 60Hz, rated working voltage to 415V and DC working voltage to 250V in industrial control circuits, as electromagnetic starters, contactors, relays and other electrical circuit control, with indicator light button is also suitable for light signal indication ...
|
|
CHINT/CHINT LA19 series buttons
The LA19 series pushbutton is suitable for electromagnetic starters, contactors, relays and other electrical circuits with AC voltage from 50Hz or 60Hz to 380V and DC voltage to 220V for remote control.
Conform to the standard: GB/T 14048.5.
Rated insulation voltage: 380V
Agree on free air ...
|
|
CHINT/CHINT HZ5 series combination switch
HZ5 series combination switch is mainly used for AC 50Hz or 60Hz, voltage 380V and below electrical circuits as power switch and cage induction motor starting, commutation, variable speed switch, can also be used for control line switching.
Comply with standards: GB/T 14048.3, IEC 60947-3.
...
|
|
CHINT/CHINT AC Contactor CJX2 Series has a mechanical life of 10 million times
Introduction: CHINT/CHINT AC contactor CJX2 series (hereinafter referred to as contactor) is mainly used for AC 50Hz (or 60Hz), rated working voltage to 690V, in the AC-3, 400 (380) V use category rated working current to 95A circuit, for long-distance connection and breaking of circuits, frequency ...
|
|
CHINT/CHINT HY23 Series Reverse Switch NF1 Load Type Switch
The NF1 load switch is suitable for electrical circuits with AC 50Hz or 60Hz and voltage 690V and below. It is widely used in power distribution systems and automation systems in construction, electric power, petrochemical and other industries. It is mainly used for the main switch of machine tools, fans and pumps, and can also be used as a small-capacity motor ...
|
|
CHINT/CHINT Terminal Appliance —NBH-63 Miniature Circuit Breaker
NBH-63 miniature circuit breaker is suitable for AC 50Hz, rated voltage 230V/400V, rated current to 63A in the line, for overload and short circuit protection, under normal circumstances, as the line of infrequent operation and conversion of the use, can also be used as a disconnecting switch for disconnecting the line for line and equipment maintenance...
|
|
CHINT/CHINT NA5 series universal circuit breaker
CHINT Xinrui NA5 series universal circuit breaker has a rated working current from 200A to 6300A, a rated limit short-circuit breaking capacity of up to 120kA, a rated working voltage of up to AC690V, and an ambient temperature of -45°C - +70°C. The product set high breaking, zero arcing, a variety of ...
|
|
CHINT/CHINT Vacuum AC Contactor NC9-400
Scope of application: NC9 series vacuum AC contactor, hereinafter referred to as contactor, is mainly used in AC 50Hz rated working voltage to 1140V, rated working current to 1000A circuit for long-distance connection and breaking circuit and can be used with appropriate thermal overload relay or electronic protector ...
|
|