DZ158LE-125□ residual current action circuit breaker is suitable for AC 50Hz, rated voltage single pole two wires, two poles 230V, three poles, three poles, four wires, four poles 400V rated current from 63A to 125A in the line, when the person is electrocuted or the leakage current of the power grid exceeds the specified value, the residual current action circuit breaker can quickly cut off the fault power supply in a very short time, protect the safety of people and electrical equipment, and can protect the overload or short circuit of the line. It can also be used for infrequent switching of lines.
Compliant with standards: GB/T 14048.2 and IEC 60947-2.
Main technical parameters and technical performance
Technical parameters item | Parameter value | Rated Operating Voltage (Ue) | 230V AC(1P+N、2P)、 400V AC(3P、3P+N、4P) | Rated current (In) | DZ158LE-125 : 63A、80A、 100A( 1P+N、2P、3P、3P+N、 4P)、125A(1P+N、2P ) DZ158LE-125H : 63A、80A 100A | Rated insulation voltage (Ui) | 500V | Rated impulse withstand voltage (Uimp) | 4kV | Rated residual operating current(△N) | 0.03A、0.05A 0.1A、 0.3A | Rated residual non-operating current (I△no) | 0.51△n | Number of poles | 1P+N、2P、 3P、 3P+N、 4P | Rated Limit Short Circuit Breaking Capacity (Icu) | 6kA(DZ158LE-125)、10kA(DZ158LE-125H) | Rated residual switching and breaking capacity (△m) | 2.5kA | This article introduces CHINT/CHINT DZ158LE-125□ residual current action circuit breaker If you are interested, please also contact our customer service, we are looking forward to your call, and hope our technology and service can bring you a better experience.
The company has been customer-centric, the concept of creating value for customers, winning the market with quality and service, and sincerely hopes to cooperate with all sectors of society to create success, create brilliance together, and work together to create a better tomorrow! In line with the concept of credibility and service-oriented, the company warmly welcomes new and old customers to inquire, visit and negotiate business!
|
More on that
|
CHINT/CHINT Miniature Circuit Breaker NBH-100□GV Photovoltaic Grid-Connected Special Circuit Breaker
NBH-100NGV and NBH-100HGV miniature circuit breakers are suitable for AC 50Hz, rated voltage to 230V or 400V, rated current to 100A, and play the role of overload and short circuit protection. At the same time, as a special supporting circuit breaker for photovoltaics, it can realize automatic opening of undervoltage and protect the line.
|
|
CHINT/CHINT NBH-125 miniature circuit breaker
NBH-125 plastic shell circuit breaker is suitable for AC 50Hz, rated voltage 230V/400V, rated current to 125A in the line, for overload and short circuit protection, under normal circumstances, as the line of infrequent operation and conversion, can also be used as a disconnection of the line for line and equipment maintenance...
|
|
CHINT NBH-100□GQ self-healing over/undervoltage protection circuit breaker
NBH-100□GQ series miniature circuit breaker is suitable for AC 50Hz, rated voltage 230V or 400V, rated current to 100A line to play overload and short circuit protection. At the same time, as an over- and under-voltage protection circuit breaker, it can realize the automatic disconnection protection of over- and under-voltage, and automatically ...
|
|
CHINT/CHINT NB8-40 miniature circuit breaker
NB8-40 miniature circuit breaker is mainly suitable for AC 50Hz, rated voltage to 240V, rated current to 40A in commercial office buildings, residential and general industrial use of terminal distribution lines, to provide overload, short circuit protection, but also under normal circumstances to the line infrequent turnover...
|
|
CHINT/CHINT NS5 series motor starter
NS5 series motor starter is mainly used in AC 50Hz (or 60Hz), working voltage to 690V, working current to 32A circuit, as a three-phase squirrel cage asynchronous motor overload, phase failure, short circuit protection and infrequent starting control for use, can be used as distribution line protection...
|
|
CHINT/CHINT Terminal Appliance —NB8-40J Miniature Circuit Breaker
NB8-40J miniature circuit breaker is mainly suitable for AC 50Hz, rated voltage to 415V, rated current to 40A in commercial office buildings, civil residential and general industrial terminal distribution lines, to provide overload, short circuit protection for the line, but also under normal circumstances for infrequent transfer of the line...
|
|
CHINT/CHINT DZ20 Series Plastic Case Circuit Breaker DZ20Y-1250
DZ20 series plastic shell circuit breaker (hereinafter referred to as circuit breaker), its rated insulation voltage is 660V, AC 50Hz, rated working voltage 380V and below, and its rated current is from 32A to 1250A. Generally used for power distribution, the rated current of type C is 160A and below, and the shell of type 630 and below ...
|
|
CHINT/CHINT Miniature Circuit Breaker NXB-125G Quota voltage 230V
Introduction: CHINT/CHINT miniature circuit breaker NXB-125G is a new type of leakage circuit breaker integrating leakage relay, leakage circuit breaker, AC contactor, undervoltage and other functions. It can automatically distinguish between slowly variable leakage and abrupt leakage (electric shock) for protection
Product parameters
...
|
|
CHINT/CHINT Terminal Appliance UVT-X1 Undervoltage Tripper
Rated Operating Voltage (Ue) : AC 230V , 50Hz;
Rated insulation voltage (Ui): 500V;
Undervoltage action setting value: (35%-70%) Ue;
Action characteristics: the external voltage ≤35%Ue, and the product should prevent the circuit breaker from closing; 35%Ue≤ external voltage ...
|
|
CHINT/CHINT YBLX-WL Series Position Switch YBLX-WL/NJ/S2
YBLX-WL travel switch is mainly used in the control circuit of AC 50Hz or 60Hz, voltage 380V, DC voltage 220V, for the travel control of the moving mechanism, the transformation of the direction or speed of the movement, the automatic control of the machine tool, the limit action of the moving mechanism and the control of the stroke or program.
Accord with...
|
|
CHINT/CHINT CJ40 Series AC Contactor CJ40-125
CJ40 series AC contactor (hereinafter referred to as contactor) is mainly used for switching and breaking circuits in power systems with AC 50Hz or 60Hz, rated voltage to 660V or 1140V, and current to 1000A.
|
|
CHINT/CHINT AX-6 auxiliary contacts
AX-6 auxiliary contact is mainly used in AC 50Hz, rated heating current to 6A, rated voltage to 415V or DC rated voltage to 130V line, which is assembled with NB1 series circuit breaker for signal indication of long-distance circuit breaker on/off.
Standards: GB/T 14048.5, IEC 6094 ...
|
|
CHINT/CHINT OUVT-X1 over/undervoltage tripper
Rated working voltage (Ue): AC 230V, 50Hz;
Overvoltage action setting value (Uo): 280(1±5%)V;
Undervoltage action setting value: (35%-70%) Ue;
Rated insulation voltage (Ui) : 500V;
Trip characteristics: Tripper combined with NXB-63 series circuit breaker ...
|
|
CHINT/CHINT Terminal Appliance —NHH-125 Disconnector
NHH-125 disconnector is suitable for AC 50Hz, rated voltage 230V/400V, rated current to 125A in the power distribution and control circuit, mainly as the main switch in the terminal combination appliances, can also be used to control all kinds of low-power electrical appliances and lighting, can be widely used in commercial and home and other places. ...
|
|
CHINT/CHINT NC5 series AC contactors
The NC5 series AC contactors are primarily used at AC 50Hz (or 60Hz) and are rated for operating voltage up to 690V at AC-3/400(380)V
Circuits rated up to 630A in the use category for long-distance switching on and off circuits, and with appropriate thermal overload relays...
|
|
CHINT/CHINT HY23 Series Forward Switch HY23-134
HY23 series instead of HZ3 series combination switch is suitable for AC 50Hz or 60Hz, voltage 380V circuit, as a power supply introduction switch, or as a three-phase squirrel cage induction motor with a control operation frequency of no more than 300 times per hour.
Rated voltage: 380
Rated current: 30
Control Electricity ...
|
|
CHINT/CHINT NXB-63H miniature circuit breaker
Rated current (In): 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A
Rated working voltage (U): 230V-(1P, 1P+N), 400V-(2P-4P, 3P+N);
Rated insulation voltage (Ui): 500V;
Frequency: 50Hz
Electromagnetic tripping ...
|
|
CHINT/CHINT Energy Meter DTSY666 220/380V5(20)A
DTSY666 type three-phase four-wire electronic prepaid electric energy meter (hereinafter referred to as electric energy meter) can realize the functions of electric energy metering, electricity pre-purchase, * large load limit, etc., the product is the ideal electric energy metering product for electricity charging reform, improve the level of scientific management of power supply, and promote electricity consumption.
Features ...
|
|
CHINT/CHINT NSC1 Series Motion Controller NSC1-R6
32-bit high-performance CPU, compiled execution mode, scan cycle is 10 times faster than analytical type, and the basic instruction single-step running time is 0.05μs.
Weight: 102
Power consumption: 1.5
Power supply: DC24V±20%
Digital inputs: 6
Output Type: Relay
Maximum Inductive Load: 80V...
|
|
CHINT/CHINT UVT-X3H undervoltage tripper
UVT-X3H under-voltage tripper is suitable for AC 50Hz, rated voltage 230V line, and NBH-125 series circuit breaker is used together, when the terminal voltage of the tripper is reduced to the under-voltage protection range, the tripper acts and drives the circuit breaker to automatically break, so as to realize the under-voltage protection of the line. ...
|
|