CHINT Xinrui NA5 series universal circuit breaker has a rated working current from 200A to 6300A, a rated limit short-circuit breaking capacity of up to 120kA, a rated working voltage of up to AC690V, and an ambient temperature of -45°C - +70°C. The product integrates high breaking, zero arcing, and a variety of intelligent protection functions, with excellent performance, which can meet the needs of different scenarios.
This article introduces the interest of CHINT/CHINT NA5 series universal circuit breaker products, please also contact our customer service, we are looking forward to your call, hope our technology and service can bring you a better experience.
The company has been customer-centric, the concept of creating value for customers, winning the market with quality and service, and sincerely hopes to cooperate with all sectors of society to create success, create brilliance together, and work together to create a better tomorrow! In line with the concept of credibility and service-oriented, the company warmly welcomes new and old customers to inquire, visit and negotiate business!
|
More on that
|
CHINT/CHINT NXBFLE-32 residual current action circuit breaker
NXBFLE-32 residual current action circuit breaker is suitable for AC 50Hz, rated voltage 230V/400V, rated current to 32A in the line, play the role of overload, short circuit and leakage protection, can also be used as infrequent line on and off under normal circumstances.
The product conforms to IEC61009-1, GB/T...
|
|
CHINT/CHINT NB1LE-40□ residual current operated circuit breaker
NB1LE-40□ residual current action circuit breaker is suitable for AC 50Hz, rated voltage single pole two wires, two poles 230V, three poles, three poles four wires, four poles 400V, rated current to 40A line, when the person is electrocuted or the leakage current of the power grid exceeds the specified value, the residual current action circuit breaker can be ...
|
|
CHINT/CHINT Terminal Blocks — JF5 Series
JF5 series base enclosed terminal block is suitable for the frequency of 50Hz or 60Hz, the rated voltage to 660V, the rated cross-sectional area of 1.5-25mm2 round copper wire for connection. This series of products is connected by screw crimping, and the wire end needs to be crimped before it can be connected to the terminal block. ...
|
|
CHINT/CHINT SHT-X3H shunt tripper
SHT-X3H shunt trip device is suitable for AC rated voltage to 400V or DC rated voltage 48V in the line, and NBH-125 series circuit breaker is used together, when the tripper terminal is connected to the rated control voltage, the trip device action and drive the circuit breaker to break automatically, so as to achieve long-distance control breaking.
|
|
CHINT/CHINT NCH8G Household AC Contactor NCH8G-25/22
NCH8G series household AC contactor (hereinafter referred to as contactor) is mainly suitable for AC 50Hz (or 60Hz), rated working voltage to 400V rated working current to 63A circuit, control household appliances and similar uses of low-inductance and micro-inductance loads; It can also be used to control household ...
|
|
CHINT/CHINT NB1L-40□ residual current action circuit breaker
NB1L-40 □ residual current action circuit breaker is suitable for AC 50Hz, rated voltage single pole two wires, two poles 230V, three poles, three poles four wires, four poles 400V, rated current to 40A line, when the person is electrocuted or the leakage current of the power grid exceeds the specified value, the residual current action circuit breaker can be used in the pole ...
|
|
CHINT/CHINT NCH8G Household AC Contactor NCH8G-25/10
NCH8G series household AC contactor (hereinafter referred to as contactor) is mainly suitable for AC 50Hz (or 60Hz), rated working voltage to 400V rated working current to 63A circuit, control household appliances and similar uses of low-inductance and micro-inductance loads; It can also be used to control household ...
|
|
CHINT/CHINT AX-X1 auxiliary contact
The main function of the AX-X1 auxiliary contact: it can be assembled with the circuit breaker to realize the signal indication of the on/off of the long-distance circuit breaker.
Conform to the standard: GB/T14048.5, IEC60947-5-1
Parameters and performance
Action characteristics: The wiring principle of the auxiliary contact is shown in Figure 1.
When the auxiliary contact is opened, the 17th and 12th terminals ...
|
|
CHINT/CHINT CKJ5 Series Vacuum AC Contactor CKJ5-630
CKJ5 series vacuum AC contactor (hereinafter referred to as contactor) is mainly used in AC 50Hz, rated working voltage to 1140V, rated working current to 630A circuit, for long-distance connection and breaking of circuits, and can be used with appropriate thermal overload relay or electronic protection ...
|
|
CHINT/CHINT S9 shunt tripper
The S9 shunt trip device (hereinafter referred to as the tripper) is mainly used for matching with NB1 or NBH8 series circuit breakers, and is suitable for long-distance shunt tripping operation in lines with AC 50Hz (or 60Hz) rated voltage to 400V.
Meets the standard: IEC60947-5-1, obtained CE certification.
3.1 Basic ...
|
|
CHINT/CHINT CKJ5 Series Vacuum AC Contactor CKJ5-160
CKJ5 series vacuum AC contactor (hereinafter referred to as contactor) is mainly used in AC 50Hz, rated working voltage to 1140V, rated working current to 630A circuit, for long-distance connection and breaking of circuits, and can be used with appropriate thermal overload relay or electronic protection ...
|
|
CHINT/CHINT AX-X3H auxiliary contact
The AX-X3H auxiliary contact complies with GB/T 14048.5 standard. It is mainly used in lines with AC rated voltage up to 415V or DC rated voltage up to 130V. Signal indication of long-distance circuit breaker when assembled with NBH-125 series circuit breaker.
The auxiliary contact is an accessory product that is assembled in the open circuit ...
|
|
CHINT/CHINT LW5D series universal transfer switch
LW5D series universal transfer switch is mainly suitable for converting electrical control circuits (electromagnetic coils, electrical measuring instruments and servo motors, etc.) in circuits with AC 50 or 60Hz, voltage to 380V, and DC voltage to 220V, and can also directly control 5.5kW three-phase cage induction motor (starting, ...
|
|
CHINT/CHINT NTP1 series industrial touch screen
1.1 System Features:
Based on the Linux system, the system is stable, efficient and reliable. Industrial-grade high-performance Cortex A8 processor with a clock speed of 600MHz. The COM port integrates RS232/422/485 communication mode. The product provides USB master station and USB slave port, and the USB slave download port supports 10 ...
|
|
CHINT/CHINT NP4 series buttons
The NP4 series pushbutton is suitable for circuit control systems with AC 50Hz or 60Hz, voltage up to 380V, and DC working voltage up to 220V. It is used for the control of electromagnetic starters, contactors, relays and other electrical circuits. The indicator button is also suitable for light signal indication.
...
|
|
CHINT/CHINT HY23 Series Reverse Switch NF1 Load Type Switch
The NF1 load switch is suitable for electrical circuits with AC 50Hz or 60Hz and voltage 690V and below. It is widely used in power distribution systems and automation systems in construction, electric power, petrochemical and other industries. It is mainly used for the main switch of machine tools, fans and pumps, and can also be used as a small-capacity motor ...
|
|
CHINT/CHINT CJ40 series AC contactors
● CJ40 series AC contactor (hereinafter referred to as contactor) is mainly used for switching on and off circuits in power systems with AC 50Hz or 60Hz, rated voltage to 660V or 1140V, and current to 1000A.
|
|
CHINT/CHINT Authorized Package — POWGRID-M
POWGRID-M intelligent AC low-voltage complete set of equipment is a new generation of low-voltage switching system designed and developed by CHINT Low-voltage Intelligent Electrical Appliance Research Institute with completely independent intellectual property rights. It integrates many advantages of similar products at home and abroad, adopts standardized and modular design, and has the ability to measure the advantages of intelligent measurement.
|
|
CHINT/CHINT Terminal Block-TB Series
The TB series is suitable for connecting wires in circuits with AC 50Hz or 60Hz, rated voltage up to 600V and rated current up to 100A. This series of products is connected by screw crimping, and the wire end needs to be crimped before it can be connected to the terminal block. Screw mounting.
Comply with the standard ...
|
|
CHINT/CHINT CJX1 Series AC Contactor Quota insulation voltage 660V
Introduction: CHINT/CHINT AC contactor CJX1-9 is mainly used for AC 50Hz or 60Hz, the rated insulation voltage is 660V-1000V, and the rated working current is 9A-475A when the rated working voltage is 380V under the AC-3 use category, and is suitable for controlling AC electric ...
|
|