The correct use and precautions of Omron electronic blood pressure monitor

Create Date: 2024-8-30 12:03:23|Source: Omron/Omron

How to use Omron blood pressure monitor

1. Rest for 10-15 minutes before using an Omron sphygmomanometer to measure blood pressure to eliminate fatigue and excitement.

You must rest for 30 minutes after exercising. The indoor ambient temperature should be kept at about 20°C. Take 3-4 deep breaths before measuring your blood pressure. Blood pressure values are different when measuring blood pressure while lying down and when sitting down. Therefore, the posture in which blood pressure is measured must be carried out in strict accordance with the operating instructions. At the same time, emotional tension and mental restlessness should be avoided during the measurement. Smoking, drinking, showering and exercising are strictly prohibited before blood pressure measurement.

2. Use Omron sphygmomanometer arm blood pressure meter, and the commonly used part is the brachial artery of the upper limbs.

Care should be taken that the cuff is at the same height as the heart. Measure with your palms facing up, roll up your sleeves (loose sleeves) to expose your upper arms, and wrap the cuff flat around the middle of your upper arms (not around the elbows). The lower edge of the cuff is about 1-2 cm from the cubital fossa. The cuff should be tightly tightened so that one finger can be inserted just right. Wound too tightly, the measured blood pressure is low; Excessive looseness is on the high side. The hose of the cuff should be placed at the brachial pulse point.
The correct use and precautions of Omron electronic blood pressure monitor
  How to use Omron sphygmomanometer

How to use an arm-type automatic blood pressure monitor

1. In a quiet, relaxed, and natural environment, take off thicker clothes such as coats and sweaters, and bare your upper arms or wear thinner clothes.

2. Try to keep a sitting position for measurement, put your arms on the table, so that the palms are facing up, and the fingers are naturally bent in the shape of a virtual fist.

3. Wrap the armband around the upper arm. The height of the armband should be approximately the same level as the heart, and the tracheal port should be on the inside of the arm, with the extension line in line with the middle finger.

Precautions for the use of Omron blood pressure monitors are as follows:

1. It is dangerous to self-judge and treat the measurement results. Follow your doctor's instructions. Because self-judgment has the potential to worsen the condition; Conditions such as diabetes, hyperlipidemia, and high blood pressure can accelerate arteriosclerosis and may also cause peripheral circulation disorders. These patients may have large differences in blood pressure values in the wrist and upper arm.

2. Patients with severe blood circulation disorders and blood diseases should use it under the guidance of a doctor. Squeezing during measurement may cause acute internal bleeding.

3. Do not use the mobile phone near the blood pressure monitor, as there is a risk of malfunction of the Omron blood pressure monitor.

4. Do not disassemble and modify the main unit and wristband of the blood pressure monitor, otherwise it will not be able to measure correctly.

More on that
The application of Omron tension control in automobile motor winding The application of Omron tension control in automobile motor winding

Process introduction In recent years, the motor industry has shown a rapid upward trend, new products, new technologies are constantly updated and iterative, resulting in increasingly fierce competition between motor manufacturers, how to improve equipment performance, improve productivity, is the current motor manufacturers need to solve the problem.   ...

What are some common failures of Omron? What are some common failures of Omron?

Common troubleshooting methods for Omron are as follows: (1) Failure of peripheral circuit components This kind of failure is more common in PLC maintenance, and it is generally a frequent occurrence in failures after a certain period of work. In the PLC control loop, if there is a component damage fault, the PLC control system ...

Omron | Sub-micron ultra-high-speed microfabrication Omron | Sub-micron ultra-high-speed microfabrication

problem Adapt to high-end manufacturing With the diversification of consumer needs and the shortening of product cycles, various digital devices such as mobile devices are pursuing high performance, small size, and thin form factors, and the manufacturing process of semiconductor packaging and electronic components has also undergone tremendous development.

FAQs on Omron PLC FAQs on Omron PLC

1.How to install the USB driver of CP1H? The computer is connected to CP1H (powered on) through a USB cable, and the PC will automatically prompt to find the new hardware and prompt to install the driver. 2.The built-in USB port of CP1H can be used ...

Omron Relays – The role of signal relays Omron Relays – The role of signal relays

1) Expand the scope of control. For example, when the control signal of a multi-contact relay reaches a certain value, it can be changed, interrupted, and connected to multiple circuits at the same time according to the different forms of contact groups. 2) Zoom in. For example, sensitive relays, intermediate relays, etc., with a very small control ...

Omron products are used in fully automated high-speed sewing and cutting Omron products are used in fully automated high-speed sewing and cutting

Process introduction The sewing and cutting line is mainly used for sewing and cutting shirt collars, sleeves and pockets, and the equipment is divided into the following 4 parts: 1. Discharging part: used for the initial positioning of sewing materials, the laser projection position is controlled by the motor, and the materials are manually placed on the platform.

【Omron industry case】Application case of laser die-cutting machine for secondary battery 【Omron industry case】Application case of laser die-cutting machine for secondary battery

Process introduction In the traditional die-cutting process, because the cutter cannot cut the material completely, the connecting frame will be left, which increases the cost of the material. In addition, the service life of the die-cutting knife is 1 million times, such as long-term continuous operation, it needs to be replaced and maintained in time, and the maintenance and debugging time is also very long.

What are the main application areas of Omron relays? What are the main application areas of Omron relays?

In terms of application fields, Omron relays can be used in the following fields: 1) Home appliance market Representative models: G5Q, G2RL, G5NB, G4A and other power relays 2) Medical market Representative models: G6J-Y, G6S, G6K and other signal relays ...

How are Omron switch relays wired? How are Omron switch relays wired?

One. Before connecting, determine the voltage required for the proximity switch, and in the case of a 3-wire system, determine whether it is PP type or P type. The proximity switch is divided into 2-wire, 3-wire and 4-wire systems. Two. Wire proximity switches are connected in series when connected to relays. i.e. the relay is connected to the proximity switch to give it ...

How to modify the program online of Omron PLC? How to modify the program online of Omron PLC?

1. After determining the object in Omron PLC, click Write Mode in the edit window. 2. Next, directly select the relevant software components and double-click. 3. At this time, you need to change the number through the ladder diagram input and select OK. 4. Such a ...

The reason why the ER light is always on after the Omron PLC is powered on The reason why the ER light is always on after the Omron PLC is powered on

1. Fault phenomenon: The ERR light is always on when the PLC is powered on, and the PLC is not working. 2. Cause of failure: (1) Poor use environment leads to oxidation and corrosion of internal MPU, memory, and even substrates. (2) Due to electromagnetic interference, noise interference, static electricity, etc., the internal MPU ...

Causes and solutions for E1 fault codes in Omron electronic sphygmomanometers Causes and solutions for E1 fault codes in Omron electronic sphygmomanometers

The E1 fault code usually appears on the display of the blood pressure monitor and indicates that the inflation pressure is too high or too low. This failure can lead to inaccurate measurement results or even inability to complete the measurement. Solution(s): 1. Check whether the cuff is worn correctly and whether it is properly tightened. ...

Instructions for the use of Omron relays Instructions for the use of Omron relays

One. Omron relays should be installed in a well-ventilated environment with room temperature and humidity, and there are no flammable gases, dusts and other dangerous factors in the installation environment to ensure that Omron relays can be used normally after being put into operation. Two. The selection of Omron relays should be in line with the actual needs.

What are the main items of Omron PLC overhaul? What are the main items of Omron PLC overhaul?

1. Overhaul the power supply. It is possible to detect whether the voltage variation range is within the permissible ± 10% at the power terminal. 2. Working environment. Focus on checking whether the temperature, humidity, vibration, dust, interference, etc. meet the standard working environment. 3. Power supply for input and output. Available in the corresponding ...

Omron's new E2EW series proximity sensors have the longest sensing range in the world Omron's new E2EW series proximity sensors have the longest sensing range in the world

Hoffman Estates, Illinois, March 24, 2020 – Manufacturers in the automotive industry are trying to capitalize on the current trend toward electric vehicles and low fuel consumption by building lightweight vehicles and favoring aluminum over iron. With the inclusion of both iron and aluminum ...

Omron C series PLC models and their main meanings Omron C series PLC models and their main meanings

Omron C series P-type machines have three types: basic, extended, and special-purpose, with a total of 4 types of CPU hosts, 6 types of I/O short-range expansion machines, and a variety of dedicated units. 1. The basic unit (also known as the host) has a CPU Among them, C stands for the series code; (1) Table ...

【Omron industry case】Application of high-end pouch battery welding machine 【Omron industry case】Application of high-end pouch battery welding machine

Process introduction In the middle process of the secondary battery, the battery welding machine first needs to quickly heat press the battery cells after winding/lamination to achieve cell compaction, and then ultrasonic welding of the positive and negative tabs of the battery cells.   problem 1. Pressure fluctuates greatly, causing ...

How to choose Omron relays How to choose Omron relays

1. Select the rated working current of the electromagnetic relay coil: For the DC electromagnetic relay driven by transistors or integrated circuits, the rated working current of the coil (generally 2 times the suction current) should be within the output current range of the driving circuit. 2. Select electromagnetic relay contact ...

A detailed description of the environment in which Omron sensors are used A detailed description of the environment in which Omron sensors are used

1. Ambient temperature The specification of the sensor will rule the ambient temperature range of the normal operation of the sensor, such as 40-85 degrees, which varies depending on the product model. It is advocated not to exceed the temperature range specified in the specification book, beyond the normal operating temperature range of the sensor, ...

How does Omron PLC input the rising/falling edge? How does Omron PLC input the rising/falling edge?

The first 1. First of all, we open the CX-P software, set the PLC model, enter the programming section, and prepare for programming. 2. Usually when we program, we are used to entering LD instruction programming, when we need to input the rising edge, we need to enter @LD0.00, you can. 3. Down...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top