A detailed description of the environment in which Omron sensors are used

Create Date: 2024-8-30 12:03:23|Source: Omron/Omron

1. Ambient temperature

The specification of the sensor will rule the ambient temperature range of the normal operation of the sensor, such as 40-85 degrees, which varies depending on the product model. It is advocated that the temperature range of the rules in the specification should not be exceeded, and the normal operating temperature range of the sensor should be exceeded, and the performance of some internal equipment will be degraded due to temperature characteristics, resulting in a decrease in accuracy, inaccurate output signal, or inability to operate. The sensor should be installed in a place with good ventilation and heat dissipation as much as possible, so as not to affect the measurement accuracy and life of the sensor due to excessive temperature.

2. Altitude

Usually the sensor is designed with altitude in mind, and the general condition is 2000 meters. However, it is not only suitable for the altitude below 2000 meters, if the altitude exceeds 2000 meters in actual use, it will affect the heat dissipation and insulation performance of the sensor. It will reduce the insulation characteristics, although the insulation can also be improved by external methods, but it is difficult to achieve and will increase the cost, in the actual selection and use is to refer to the rules of the 1EC60664-1 specification to reduce the derating use, please refer to IE°C60664-1 Section 5.1.4, Table VIII.2 for derating coefficients. The problem of heat dissipation can be solved relatively simply by means of forced air cooling.

3. Device orientation

Because the sensor is a non-contact measurement, most of the sensors detect the magnetic field around the live conductor, so there should not be a strong magnetic field near the sensor, and the equipment that simply generates the magnetic field. It includes transformers, reactors, and conductors that flow high currents, etc. Especially in three-phase testing, adjacent sensors should not be installed too closely. In the case of space promise, the distance is as large as possible.

Sometimes it will be constrained by the cabinet and its internal layout, and it is difficult to leave a satisfying space, in this case, it is advocated that the sensor dislocation device, especially the sensor of the H8LL principle, should be as far as possible to let the orientation principle of the HALL equipment magnetic field source.
A detailed description of the environment in which Omron sensors are used

More on that
Omron CP1 series PLC interrupt classification Omron CP1 series PLC interrupt classification

1. I/O direct interrupt, which is the change of interrupt input from the built-in input unit on the CPU rack (0→1; 1→0). 2. Counting interrupt, the built-in input pulse of the CPU unit of the PLC is counted, and the interrupt is executed when the count reaches the set value. ...

What are the maintenance precautions for Omron relays? What are the maintenance precautions for Omron relays?

1. In the operation of Omron relay, if there is any abnormal sound or other abnormal phenomena, the operation should be stopped immediately, and the professional maintenance personnel should be notified to come for maintenance, and the normal operation can only be put into normal operation after troubleshooting. 2. During the maintenance process, check whether the spring is deformed, old...

Omron PLC's equipment disassembly sequence and method Omron PLC's equipment disassembly sequence and method

(1) Shutdown for maintenance, more than two people must supervise the operation; (2) Change the mode selector switch on the front panel of the CPU from "Run" to "Stop" position; (3) Turn off the main power supply of PLC power supply, and then turn off other power supplies to the mold saka; (4) ...

Omron PLC cannot be connected to the computer, and the selected port is temporarily used by another program Omron PLC cannot be connected to the computer, and the selected port is temporarily used by another program

Compile first, then click the PLC drop-down menu, select online work, pop up to prepare to connect to the PLC, the point is, if the PLC selected by the program is the same as the actual one, and the COM port is set correctly, there is no problem. After connecting, click on the PLC drop-down menu - > transfer - > from the PLC, and the program will be transferred to the computer. ...

Common problems and solutions in the maintenance process of Omron PLC Common problems and solutions in the maintenance process of Omron PLC

1. CPU abnormality: When the CPU is abnormally alarmed, check all the devices connected to the internal bus of the CPU unit. The specific method is to replace the units that may have problems in turn, find out the problem units, and deal with them accordingly 2. Memory abnormality: Memory anomaly ...

There are four main characteristics of Omron PLC There are four main characteristics of Omron PLC

1. High reliability The PLC replaces a large number of intermediate relays and time relays in the relay control system with software, and the wiring can be reduced to less than one-tenth of the relay control system, which greatly reduces the possibility of poor contact contact. In addition, the PLC itself has a strong self-diagnosis ...

Instructions for the use of Omron relays Instructions for the use of Omron relays

One. Omron relays should be installed in a well-ventilated environment with room temperature and humidity, and there are no flammable gases, dusts and other dangerous factors in the installation environment to ensure that Omron relays can be used normally after being put into operation. Two. The selection of Omron relays should be in line with the actual needs.

FAQs on Omron PLC FAQs on Omron PLC

1.How to install the USB driver of CP1H? The computer is connected to CP1H (powered on) through a USB cable, and the PC will automatically prompt to find the new hardware and prompt to install the driver. 2.The built-in USB port of CP1H can be used ...

Analysis of the location and cause of Omron PLC failure Analysis of the location and cause of Omron PLC failure

1. External equipment failure. Such faults come from external devices such as various sensors, switches, actuators, and loads. The failure of this part of the equipment will directly affect the control function of the system. This type of failure is usually caused by the quality and longevity of the equipment itself. 2. System failure ...

Omron products are used in fully automated high-speed sewing and cutting Omron products are used in fully automated high-speed sewing and cutting

Process introduction The sewing and cutting line is mainly used for sewing and cutting shirt collars, sleeves and pockets, and the equipment is divided into the following 4 parts: 1. Discharging part: used for the initial positioning of sewing materials, the laser projection position is controlled by the motor, and the materials are manually placed on the platform.

The application of Omron tension control in automobile motor winding The application of Omron tension control in automobile motor winding

Process introduction In recent years, the motor industry has shown a rapid upward trend, new products, new technologies are constantly updated and iterative, resulting in increasingly fierce competition between motor manufacturers, how to improve equipment performance, improve productivity, is the current motor manufacturers need to solve the problem.   ...

Possible malfunction of Omron switch contacts Possible malfunction of Omron switch contacts

1. The internal components of Omron switch are not in good contact. 2. Omron switch malfunction. 3. The Omron switch is fused. 4. The insulation performance of Omron switch becomes weaker. ...

Omron PLC pre-maintenance preparation, maintenance procedures Omron PLC pre-maintenance preparation, maintenance procedures

(1) Prepare tools before overhaul; (2) In order to ensure that the function of the component does not fail and the template is not damaged, it is necessary to use protective devices and carefully make anti-static preparations; (3) Contact the dispatcher and operator before the overhaul, and hang the maintenance card at the place where the maintenance card is hung. ...

Fault maintenance methods commonly encountered in the operation of Omron PLC Fault maintenance methods commonly encountered in the operation of Omron PLC

(1) Failure of peripheral circuit components This kind of failure is relatively common in PLC maintenance and usually occurs frequently after a certain period of work. If there is a component damage fault in the PLC control loop, the PLC control system will stop working immediately and automatically. The input circuit is a PLC receiving switching quantity ...

What are the main application areas of Omron relays? What are the main application areas of Omron relays?

In terms of application fields, Omron relays can be used in the following fields: 1) Home appliance market Representative models: G5Q, G2RL, G5NB, G4A and other power relays 2) Medical market Representative models: G6J-Y, G6S, G6K and other signal relays ...

Omron's new E2EW series proximity sensors have the longest sensing range in the world Omron's new E2EW series proximity sensors have the longest sensing range in the world

Hoffman Estates, Illinois, March 24, 2020 – Manufacturers in the automotive industry are trying to capitalize on the current trend toward electric vehicles and low fuel consumption by building lightweight vehicles and favoring aluminum over iron. With the inclusion of both iron and aluminum ...

The solution to the E4 fault code on the Omron electronic blood pressure monitor The solution to the E4 fault code on the Omron electronic blood pressure monitor

The E4 fault code usually appears on the display of the blood pressure monitor, indicating that the blood pressure monitor is poorly connected to the cuff or that the cuff is falling off. This failure can lead to inaccurate measurement results or even inability to complete the measurement. Solution(s): 1. Check that the cuff is worn correctly and whether it is loose...

How to connect Omron plc IP address? How to connect Omron plc IP address?

1. The IP address of the computer is automatically obtained. 2. The computer is directly connected to the PLC network port. 3. Open the DirectEthernetUtility software. Software Setup Start - > All Programs - > OMRON - >Communications Middleware Utilities - > DirectE...

【Omron Industry Case】Application case of robot in cell stack welding 【Omron Industry Case】Application case of robot in cell stack welding

Equipment Overview The stack welding machine is mainly used for the overlap welding of monocrystalline and polycrystalline cells in fully automatic crystalline silicon solar cell modules, and is suitable for series welding of small-size crystalline silicon solar cells.

Introduction to the characteristics of Omron 3G3RX series inverter Introduction to the characteristics of Omron 3G3RX series inverter

1. High starting torque of more than 200% at 0.3Hz, 0Hz to ensure 150% torque output; 2. Closed-loop vector has servo functions such as position control, origin reset, and electronic gear ratio; 3. Over-current and over-voltage suppression function; 4. The fast ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top