Fisher Fisher – Why is there a bend between the gauge and the pipe connection?

Create Date: 2024-8-30 12:03:23|Source: Fisher

When the pressure gauge is connected to the pipeline, a bend should be added between the pressure gauge and the pipe connection. Why is that? What does this do? Let's take a look!
Fisher Fisher – Why is there a bend between the gauge and the pipe connection?
This thing that connects the pressure gauge and the pipe is the pressure gauge bend (also referred to as the gauge bend), which is officially called the buffer pipe. It is used to connect the fittings between the pressure gauge and the equipment or pipeline measured by the pressure gauge, and is used to buffer the instantaneous impact of the measured medium on the pressure gauge spring tube, which can well protect the mechanical structure of the digital indicator or the pressure sensor from damage and prolong the service life.

There are many kinds of tubes, and it is necessary to choose buffer tubes of different materials to ensure the accuracy of measurement and the normal operation of the measurement system.

The scientific name of this elbow is called condenser pipe or siphon pipe, according to the "HG/T20581-2012" version of the HK03 pressure / differential pressure measuring instrument pipeline connection diagram 6.4 installation instructions in the installation instructions "For steam and other condenseable hot gases, and when the medium temperature exceeds 60 °C, the installation diagram with a condenser pipe (or siphon) should be selected for the pressure gauge installed in situ, the purpose of which is to passivate the gas medium to prevent damage to the instrument."

Of course, the "SH/T3104" instrument installation design specification also has a similar description.

There are two forms of pressure gauge bends: one is an annular bend and the other is a U-bend

The purpose of the pressure gauge bend is to protect the transmission mechanism inside the gauge from the damage of the medium temperature and the corrosiveness of the medium. Usually if the medium has a certain corrosiveness, a pressure gauge bend must be added, and when the temperature of the medium is greater than 60 °C, a pressure gauge bend must be added. If the pressure gauge is installed on a clean drinking water system, it does not need to be installed.

It also has the effect of reducing vibration and impact, and also plays a certain role in heat dissipation for higher temperature mediums, so as to protect the pressure gauge and reduce the temperature influence error of the pressure gauge. The damping screws at the orifice of some pressure gauge joints play a throttling buffer effect by reducing the flow area, which is mainly useful for the medium pressure pulse.

More on that
Fisher Fisher - Hazards and Protection of Abnormal Pressure Boost in the Cavity of Gate Valves Fisher Fisher - Hazards and Protection of Abnormal Pressure Boost in the Cavity of Gate Valves

Gate valves usually have single ram, double ram, wedge, parallel and other structural designs, among which wedge double ram (Z42, Z62 series) and wedge elastic ram (Z40, Z60 series) are widely used, the former when the gate is closed, the gate automatically fits the valve seats on both sides, and automatically compensates the processing position of the wedge angle.

United States Fisher pneumatic valve positioner fault repair and protection methods United States Fisher pneumatic valve positioner fault repair and protection methods

United States Fisher Pneumatic Valve Positioner is the primary accessory to the Pneumatic Control Valve, which is a single-output valve positioner. It describes the main features and common faults of the valve positioner, as well as the treatment methods and protection methods. 1. The main features of the locator (1) Large-diameter pilot ...

Fisher Fisher Control Valve Selection Parameter Requirements Fisher Fisher Control Valve Selection Parameter Requirements

1. Medium (medium state, medium density, medium viscosity)? 2. Pressure range (design pressure?) Pre-valve pressure? After-valve pressure? Large differential pressure? Critical pressure? Saturated vapor pressure? ) 3. Flow rate (*** small?) Normal? Big? ) 4. Temperature? 5. Actuator ...

Fisher Fisher - Five Essentials for Valve Installation Fisher Fisher - Five Essentials for Valve Installation

Emerson's Fisher Fisher valve installation five key points: First, direction. Many valves are directional. Such as globe valves, throttle valves, pressure reducing valves, check valves, etc. , if installed in reverse, it will ...

What are the conditions that need to be paid attention to when choosing a FISHER regulator in United States? What are the conditions that need to be paid attention to when choosing a FISHER regulator in United States?

United States FISHER gas equipment has first-class quality and advanced technology, which is the technical vane of the gas equipment industry. It provides high-quality products and technologies, consulting, project management and maintenance services for specific gas equipment industries. FISHER is a Fortune 500 company in the world.

Understanding flash in control valves and how to minimize metal corrosion damage? Understanding flash in control valves and how to minimize metal corrosion damage?

The Fisher FISHER control valve reduces maintenance costs, minimizing the effects of metal corrosion damage due to water spray. Learn about flash evaporation in control valves Flickering occurs when a liquid flows through a control valve and evaporates and retains the vapor. Scintillation with choke flow and cavitation have ...

Fisher Fisher-1098EGR and 1098H-EGR Decompression Regulators Fisher Fisher-1098EGR and 1098H-EGR Decompression Regulators

The Fisher Model 1098-EGR and 1098H-EGR regulators provide economical and accurate pressure control in a variety of applications; natural gas distribution systems; gas supply for industrial boilers, furnaces, ovens and mixers; and large commercial/industrial establishments such as shopping malls and schools. They are also used in industrial ...

Fisher Fisher - Installation height for switches, sockets, angle valves, faucets, etc Fisher Fisher - Installation height for switches, sockets, angle valves, faucets, etc

Installation Height: Strong current box: generally 1.8 meters from the ground Weak current box: generally 0.3 meters from the ground Smoke extractor: The kitchen function socket is 1.1 meters high from the ground, and the range hood socket is 1.8 meters Refrigerator socket: The refrigerator socket is 0.3 meters Washing machine socket: The socket of the washing machine is 1.4 meters from the ground ...

The Fisher Fisher Valve Positioner DVC2000 is quick and easy to commission The Fisher Fisher Valve Positioner DVC2000 is quick and easy to commission

How to set the parameters DVC2000 Fisher valve positioner: 1. Remove the shell first, then wiring it, then turn on the power supply of the current generator to send 4mA-20mA current signal to turn on the LCD display, and then select the language. How to operate: Press and hold the four keys up, down, left and right at the same time ...

Fisher - Valve installation, maintenance, and operation Fisher - Valve installation, maintenance, and operation

To extend the life of a Fisher valve, most of us pay attention to installation and maintenance, but operation is also important. For valves, it is necessary to be able not only to install and maintain, but also to operate. Dongguang valve pointed out: valve installation, maintenance, operation, no one is missing...

Fisher Fisher—DVC6200p Digital Valve Controller Fisher Fisher—DVC6200p Digital Valve Controller

The Fisher FIELDVUEDVC6200p digital valve controller is a PROFIBUSPA communication instrument with a non-link, non-contact stroke feedback. In addition to the traditional conversion function of digital signals to pneumatic output pressure, the DVC6200p digital valve controller provides easy access to information critical ...

What are the advantages and disadvantages of Fisher Fisher - Globe Valves? What are the advantages and disadvantages of Fisher Fisher - Globe Valves?

Today we will explain what are the advantages and disadvantages of the globe valve, we all know that the globe valve is a common on-off valve that cuts off the pipeline medium, let's take a look. Globe valves have the following advantages: 1. The structure is simple, and the manufacturing and maintenance are relatively convenient. 2. Work itinerary ...

Fisher Fisher-Cavitation Valve Trim helps improve plant availability and safety. Fisher Fisher-Cavitation Valve Trim helps improve plant availability and safety.

Emerson's Fisher ™ Kaft Hex Valve Strict working valve trimming reduces or eliminates cavitation to improve rotary valve performance and extend service life. The Fisher Vee-Ball Rotary™ Control Valve is now available with the Cavertro ™ Hex Valve Anti-Cavitation Trim to reduce or eliminate the effects of cavitation.

Fisher – Fisher – Valve positioner hardware system design Fisher – Fisher – Valve positioner hardware system design

The system hardware design of the valve positioner needs to reduce the interference between the analog ground and the digital ground, and at the same time make full use of the internal space of the positioner housing to divide the hardware system into two parts: the main control board and the interface board. Among them, the main control board of the valve positioner includes a single-chip microcomputer Z small system and a human-computer interaction model.

Fisher Fisher - What Industries Need Valves? Fisher Fisher - What Industries Need Valves?

Fisher valve application types In terms of the types of application valves, there are many types of valves used in machinery, metallurgy, petrochemical, chemical industry, urban construction and other industries. Especially in the machinery industry, all kinds of valves are basically used. In addition to the machinery industry, safety valves are mainly used in the chemical industry; Butterfly valves should be ...

Fisher Fisher - Valve*** should be ready to go out into the world Fisher Fisher - Valve*** should be ready to go out into the world

Valves should be prepared to go to the world , to have a sense of innovation. With a sense of innovation, it will motivate enterprises to work hard and seize opportunities. Wenzhou Yongjia market Longwan market and other areas of the valve industry has a lot of enterprises still use the family workshop model, urgently need to establish a modern ...

Fisher Fisher Asset Monitor Edge Analytics Appliance facilitates the digital transformation of assets Fisher Fisher Asset Monitor Edge Analytics Appliance facilitates the digital transformation of assets

Emerson's Asset Monitor edge analytics appliance improves visibility into critical assets and adds predictive analytics. Emerson introduces the AMS Asset Monitor Edge Analytics Appliance to digitally transform data and analytics for critical assets to improve operational performance and decision-making. AMS ...

Fisher Fisher – What are the causes and ways to eliminate leaks in valve disc and seat seals? Fisher Fisher – What are the causes and ways to eliminate leaks in valve disc and seat seals?

There are two types of leakage between the valve core and the valve seat: 1. Damaged leakage; 2. Valve position leakage. For metal-sealed valves, breakage leakage refers to the default sealing line between the valve core and the valve seat, which makes the sealing line disconnected.

Applications and prospects of Fisher DVC6200 valve positioner in the chemical industry Applications and prospects of Fisher DVC6200 valve positioner in the chemical industry

Fisher DVC6200 valve positioner has been fully verified in the global market and the quality of trustworthy and reliable products, has made a great contribution to industrial automation fluid control, visible industries are petroleum, chemical, electric power, paper, pharmaceutical, steel, water conservancy, ...

Fisher does not have an electric control valve Fisher does not have an electric control valve

First of all, we must know a concept, what is a conditioning valve, that is, a control valve. Control devices for regulating fluid flow in industrial process control systems. It can adjust the process parameters such as pressure, temperature, flow rate, and liquid level of the fluid by manipulating the fluid flow Conditioning valve composition: valve body ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top