Rated insulation voltage (Ui): 500V;
Rated operating current at different rated operating voltages (see Table 1)
Usage Category: AC-12, DC-12.
Rated Operating Voltage (V) | Rated Operating Current(A) | AC400 | 3 | AC 230 | 6 | AC/DC48 | 3 | AC/DC 24 | 6 | Action characteristics: At 70%-10% of the rated control power supply voltage, the tripper should act reliably to disconnect the circuit breaker. The wiring principle of the tripper is shown in Figure 1. When the tripper is opened, the C2 and 12 terminals are turned on, and the external safety signal light is on, when the tripper is closed, the C2 and 14 terminals are turned on, and the external warning signal light is on, when the tripper is closed, the external button is turned on, the mechanism of the tripper trips and drives the circuit breaker to trip and break. At the same time, the tripper indicator displays a trip mark.
Mechanical life: 4000 times of tripper operation life.
This article introduces CHINT/CHINT terminal appliance SHT-X3 shunt tripper if you are interested, please also contact our customer service, we are looking forward to your call, and hope that our technology and service can bring you a better experience.
The company has been customer-centric, the concept of creating value for customers, winning the market with quality and service, and sincerely hopes to cooperate with all sectors of society to create success, create brilliance together, and work together to create a better tomorrow! In line with the concept of credibility and service-oriented, the company warmly welcomes new and old customers to inquire, visit and negotiate business!
|
More on that
|
CHINT/CHINT S9 shunt tripper
The S9 shunt trip device (hereinafter referred to as the tripper) is mainly used for matching with NB1 or NBH8 series circuit breakers, and is suitable for long-distance shunt tripping operation in lines with AC 50Hz (or 60Hz) rated voltage to 400V.
Meets the standard: IEC60947-5-1, obtained CE certification.
3.1 Basic ...
|
|
CHINT/CHINT YBLX-HL series travel switch
YBLX-HL travel switch is mainly used in the control circuit of AC 50Hz or 60Hz, voltage 380V, DC voltage 220V, for the travel control of the moving mechanism, the transformation of the direction or speed of the movement, the automatic control of the machine tool, the limit action of the moving mechanism and the control of the stroke or program.
Comply with the standard ...
|
|
CHINT/CHINT DW15 series universal circuit breaker
DW15 series universal circuit breaker (hereinafter referred to as circuit breaker) is suitable for AC 50Hz, rated working current 200A to 6300A, rated working voltage AC 380V, AC 1140V distribution network, used to distribute electric energy and power supply lines and power supply equipment overload, undervoltage, short circuit protection...
|
|
CHINT/CHINT Single Magnetic Circuit Breaker NB8-63M
Introduction: CHINT/CHINT Miniature Circuit Breaker NXB-40 is a new type of leakage circuit breaker integrating leakage relay, leakage circuit breaker, AC contactor, undervoltage and other functions. It can automatically distinguish between slowly variable leakage and abrupt leakage (electric shock) for protection
Product parameters
Forehead...
|
|
CHINT/CHINT YBLX-WL Series Position Switch YBLX-WL/CL
YBLX-WL travel switch is mainly used in the control circuit of AC 50Hz or 60Hz, voltage 380V, DC voltage 220V, for the travel control of the moving mechanism, the transformation of the direction or speed of the movement, the automatic control of the machine tool, the limit action of the moving mechanism and the control of the stroke or program.
Accord with...
|
|
CHINT/CHINT NB1L-40□ residual current action circuit breaker
NB1L-40 □ residual current action circuit breaker is suitable for AC 50Hz, rated voltage single pole two wires, two poles 230V, three poles, three poles four wires, four poles 400V, rated current to 40A line, when the person is electrocuted or the leakage current of the power grid exceeds the specified value, the residual current action circuit breaker can be used in the pole ...
|
|
CHINT/CHINT NM1B series plastic shell circuit breaker NM1B-160S
The circuit breaker is rated for insulation voltage up to 800V, suitable for AC 50Hz, rated working voltage up to 400V, rated working current from 10A to 250A in the distribution network circuit, used to distribute power and protect lines and power supply equipment from overload, short circuit, undervoltage and other faults. At the same time ...
|
|
CHINT/CHINT NPH1 series buttons
NPH1 series push button is suitable for AC 50Hz or 60Hz, rated working voltage to 415V and DC rated voltage to 250V in industrial control circuits, as electromagnetic starters, contactors, relays and other electrical circuit control, with indicator light button is also suitable for light signal indication ...
|
|
CHINT/CHINT ND9 signal light
ND9 signal light is suitable for AC 50Hz/60Hz, rated voltage up to 230V, DC voltage up to 230V circuit control system. It is used as an indication signal, preset signal, accident signal and other indication of telecommunications, electrical and other lines.
Standards: GB/T 14048.5, IEC 60947-5-1 ...
|
|
CHINT/CHINT NXBLE-125 residual current action circuit breaker
CHINT/CHINT NXBLE-125 residual current action circuit breaker
Rated current (In): 63A, 80A, 100A, 125A (1P+N, 2P);
Rated Residual Operating Current (IOn) : AC type: 0.03A, 0.05A, 0.075A, 0.1A, 0.3A; Type A: 0.03A, ...
|
|
CHINT/CHINT NB1L-63 residual current action circuit breaker
NB1L-63 residual current action circuit breaker is suitable for AC 50Hz, rated voltage single pole two wires, two poles 230V, three poles, three poles four wires, four poles 400V, rated current to 63A in the line, when the person is electrocuted or the leakage current of the power grid exceeds the specified value, the residual current action circuit breaker can be used in the pole ...
|
|
CHINT/CHINT DZ20 Series Plastic Case Circuit Breaker DZ20Y-400
DZ20 series plastic shell circuit breaker (hereinafter referred to as circuit breaker), its rated insulation voltage is 660V, AC 50Hz, rated working voltage 380V and below, and its rated current is from 32A to 1250A. Generally used for power distribution, the rated current of type C is 160A and below, and the shell of type 630 and below ...
|
|
CHINT CKJ5 series vacuum AC contactor
CKJ5 series vacuum AC contactor (hereinafter referred to as contactor) is mainly used in the circuit of AC 50Hz, rated working voltage to 1140V, rated working current to 630A, for long-distance connection and breaking circuits, and can be related to appropriate thermal overload relays or electronic protectors, etc.
|
|
CHINT/CHINT Authorized Package Product — POWGRID-FD
Product Overview
It is suitable for terminal circuits with AC 50HZ and load current not exceeding 100A, and the normal operating temperature is -25°C to +60°C.
Technical Parameter Item: Parameter value
Compliant with standard: GB/T 17466.1 GB/T 17466.24
Installation: Concealed/surface-mounted
Number of digits: ...
|
|
CHINT/CHINT DZ20 Series Plastic Case Circuit Breaker DZ20Y-1250
DZ20 series plastic shell circuit breaker (hereinafter referred to as circuit breaker), its rated insulation voltage is 660V, AC 50Hz, rated working voltage 380V and below, and its rated current is from 32A to 1250A. Generally used for power distribution, the rated current of type C is 160A and below, and the shell of type 630 and below ...
|
|
CHINT/CHINT OVT-X3H Overvoltage Tripper
OVT-X3H overvoltage tripper is suitable for AC 50Hz, rated voltage 230V line, and NBH-125 series circuit breaker is used together, when the voltage at the end of the tripper rises to the voltage protection range, the tripper acts and drives the circuit breaker to automatically break, so as to achieve the overvoltage protection of the line.
...
|
|
CHINT/CHINT Transfer Switch LW5D Series Operating frequency 300/h
Introduction: LW5D series universal transfer switch is mainly suitable for converting electrical control circuits (electromagnetic coils, electrical measuring instruments and servo motors, etc.) in circuits with AC 50 or 60Hz, voltage to 380V, DC voltage to 220V, and can also directly control 5.5kW three-phase cage induction motors.
|
|
CHINT/CHINT NA1 series universal circuit breaker
NA1 series universal circuit breaker (hereinafter referred to as circuit breaker) is suitable for AC 50Hz, rated working voltage to AC690V, rated working current to 6300A and below in the distribution network, used to distribute electric energy and protect lines and power equipment from overload, undervoltage, short circuit, single-phase grounding, etc.
|
|
CHINT/CHINT Miniature Circuit Breaker NB8-63 rated frequency 50Hz
Introduction: CHINT/CHINT miniature circuit breaker NB8-63 miniature circuit breaker is mainly suitable for AC 50Hz, rated current to 63A in commercial office buildings, residential and general industrial terminal distribution lines, to provide overload, short circuit protection for the line, but also under normal circumstances...
|
|
CHINT/CHINT Terminal Appliances — Terminal Box — NX50 Series Flush-mounted Distribution Box (Cabinet)
NX50 is a high-end distribution box newly developed by CHINT Research Institute, which is widely used in household indoor power distribution to ensure the safety of various indoor electrical facilities, including lighting, kitchen equipment, air conditioning and other equipment. It can also be used for office buildings, shopping mall decoration, etc.
This article introduces CHINT/CHINT ...
|
|