DW15 series universal circuit breaker (hereinafter referred to as circuit breaker) is suitable for AC 50Hz, rated working current 200A to 6300A, rated working voltage AC 380V, AC 1140V distribution network, used to distribute power and power supply lines and power supply equipment overload, undervoltage, short circuit protection.
The circuit breaker can be used as an infrequent conversion of the line under normal conditions, and can also be used as an infrequent start of the motor under normal conditions, and the circuit breaker with a rated current of 630A at the shell level also has a drawer type.
Comply with standards: GB/T 14048.2, IEC 60947-2.
This article introduces CHINT/CHINT DW15 series universal circuit breaker If you are interested, please also contact our customer service, we are looking forward to your call, and hope our technology and service can bring you a better experience.
The company has been customer-centric, the concept of creating value for customers, winning the market with quality and service, and sincerely hopes to cooperate with all sectors of society to create success, create brilliance together, and work together to create a better tomorrow! In line with the concept of credibility and service-oriented, the company warmly welcomes new and old customers to inquire, visit and negotiate business!
|
More on that
|
CHINT/CHINT NM1 Series Plastic Case Circuit Breaker (New Platform)
The circuit breaker is rated for insulation voltage up to 800V, suitable for AC 50Hz/60Hz, rated working voltage up to 690V (415V for 2P products and NM1-63), rated working current from 10A to 250A in the distribution network circuit, used to distribute power and protect line and power supply equipment from overload, short circuit ...
|
|
CHINT/CHINT NU5 surge protector
NU5-I.+II. surge protective devices comply with GB/T 18802.11. It is suitable for AC 50Hz, rated voltage of single-phase 230V/ three-phase 400V power distribution and control system, meets SPD level I and II tests, and is used to suppress transient overvoltage lower than the equipment impulse resistance overvoltage, venting ...
|
|
CHINT/CHINT CJX1-K Series Contactors The operating frequency is 1200 hours
Introduction: CJX1-K series AC vacuum contactor (hereinafter referred to as contactor), mainly used for AC 50Hz-60Hz, rated insulation voltage of 1000V, rated working voltage of 380V under the AC-3 use category of rated working current to 820A in the circuit, for long-distance connection and disconnection ...
|
|
CHINT/CHINT AX-5 auxiliary contacts
The AX-5 auxiliary contact is suitable for AC 50Hz, the agreed heating current to 6A, the rated voltage to 415V or the DC rated voltage to 130V, and it is assembled with the NL1 residual current action circuit breaker for the signal indication of the long-distance circuit breaker.
Conform to the standard: GB/T 14048.5, ...
|
|
CHINT/CHINT NXMF series molded case circuit breaker
NXMF series circuit breakers are suitable for AC 50/60Hz, rated working voltage to 690V, rated working current from 10A to 630A in the distribution network circuit, used to distribute power and protect lines and power equipment from overload, short circuit, undervoltage and other faults. At the same time, it can also be used as an electric motor ...
|
|
CHINT/CHINT NC1 Series AC Contactor Withstand voltage 6kv
Introduction: CHINT/CHINT AC contactor NC1-09 (Z) (hereinafter referred to as contactor), mainly used for AC 50Hz (or 60Hz), rated working voltage to 690V, in AC-3, 400 (380) V use category rated working current to 95A in the circuit, for long-distance connection and breaking circuit ...
|
|
CHINT NBH-100□GQ self-healing over/undervoltage protection circuit breaker
NBH-100□GQ series miniature circuit breaker is suitable for AC 50Hz, rated voltage 230V or 400V, rated current to 100A line to play overload and short circuit protection. At the same time, as an over- and under-voltage protection circuit breaker, it can realize the automatic disconnection protection of over- and under-voltage, and automatically ...
|
|
CHINT/CHINT CJ40 Series AC Contactor CJ40-315
CJ40 series AC contactor (hereinafter referred to as contactor) is mainly used for switching and breaking circuits in power systems with AC 50Hz or 60Hz, rated voltage to 660V or 1140V, and current to 1000A.
|
|
CHINT/CHINT CJ19 Series Switching Capacitor Contactor CJ19-115
CJ19 series switching capacitor contactor (hereinafter referred to as contactor) is mainly used in power lines with AC 50Hz (or 60Hz) and rated working voltage to 690V, which is used for low-voltage reactive power compensation equipment to put in or remove low-voltage shunt capacitors. Contactors with inhibition ...
|
|
CHINT/CHINT Terminal Appliance —NB8-63M Single Magnetic Circuit Breaker
NB8-63M single magnetic circuit breaker is mainly suitable for AC 50Hz, rated voltage to 415V, rated current to 63A in commercial office buildings, civil residential and general industrial use of terminal distribution lines, to provide short circuit protection for the line, but also under normal circumstances to the line infrequent conversion operation...
|
|
CHINT/CHINT AX-X1 auxiliary contact
The main function of the AX-X1 auxiliary contact: it can be assembled with the circuit breaker to realize the signal indication of the on/off of the long-distance circuit breaker.
Conform to the standard: GB/T14048.5, IEC60947-5-1
Parameters and performance
Action characteristics: The wiring principle of the auxiliary contact is shown in Figure 1.
When the auxiliary contact is opened, the 17th and 12th terminals ...
|
|
CHINT/CHINT HZ12 Series Combination Switch (Power Cut-off Switch) HZ12-40
HZ12 series power cut-off switch is suitable for AC 50Hz or 60Hz, voltage to 550V circuit, as the power supply cut off and on.
Comply with standards: GB/T 14048.3, IEC 60947-3.
Ith A:40
Ui A:550
Ue V:380
Ie/A(AC-23A): 40
...
|
|
CHINT/CHINT NSC1 Series Motion Controller NSC1-P2
32-bit high-performance CPU, compiled execution mode, scan cycle is 10 times faster than analytical type, and the basic instruction single-step running time is 0.05μs.
Weight: 102
Power consumption: 1.5
Power supply: DC24V±20%
Digital inputs: 8
This article introduces the CHINT/CHINT NSC1 series motion controller.
|
|
CHINT/CHINT Terminal Appliance —NH3-100 Isolator
NH3-100 disconnector (hereinafter referred to as the switch) is suitable for AC 50Hz, rated voltage to 230V or 400V, rated current to 100A in the resistance and inductance mixed circuit, mainly for no load to turn on or off the circuit, for the line and power supply to turn on or isolate. Especially suitable for line ...
|
|
CHINT/CHINT Miniature Circuit Breaker NXB-40 has a mechanical life of 20,000 times
Introduction: CHINT/CHINT Miniature Circuit Breaker NXB-40 is a new type of leakage circuit breaker integrating leakage relay, leakage circuit breaker, AC contactor, undervoltage and other functions. It can automatically distinguish between slowly variable leakage and abrupt leakage (electric shock) for protection
Product parameters
Forehead...
|
|
CHINT/CHINT Miniature Circuit Breaker NB8-63 rated frequency 50Hz
Introduction: CHINT/CHINT miniature circuit breaker NB8-63 miniature circuit breaker is mainly suitable for AC 50Hz, rated current to 63A in commercial office buildings, residential and general industrial terminal distribution lines, to provide overload, short circuit protection for the line, but also under normal circumstances...
|
|
CHINT/CHINT NXAF series universal circuit breaker
NXAF series universal circuit breaker is suitable for AC 50/60Hz, rated working voltage to AC690V, rated working current to 4000A and below in the distribution network, used to distribute electric energy and protect lines and power equipment from overload, undervoltage, short circuit, single-phase grounding and other faults; The break ...
|
|
CHINT/CHINT NSC1 Series Motion Controller NSC1-R6
32-bit high-performance CPU, compiled execution mode, scan cycle is 10 times faster than analytical type, and the basic instruction single-step running time is 0.05μs.
Weight: 102
Power consumption: 1.5
Power supply: DC24V±20%
Digital inputs: 6
Output Type: Relay
Maximum Inductive Load: 80V...
|
|
CHINT/CHINT AC Contactor CJX2 Series has a mechanical life of 10 million times
Introduction: CHINT/CHINT AC contactor CJX2 series (hereinafter referred to as contactor) is mainly used for AC 50Hz (or 60Hz), rated working voltage to 690V, in the AC-3, 400 (380) V use category rated working current to 95A circuit, for long-distance connection and breaking of circuits, frequency ...
|
|
CHINT/CHINT DZ267LE-32 residual current circuit breaker
DZ267LE-32 residual current action circuit breaker (hereinafter referred to as residual current circuit breaker) is mainly suitable for AC 50Hz, rated voltage 230V, rated current to 32A circuit, as a personal electric shock, equipment leakage protection, and overload, short circuit protection function, can also be used in the positive ...
|
|