LE series is a new generation of high-performance small and medium-sized PLC products launched by Hollysys, which is suitable for small and medium-sized industrial equipment control and distributed long-distance monitoring applications. LE-PLC combines the compact structure of small PLC products with the rich functional advantages of medium-sized PLC products, and can support up to 20 local IO or long-distance IO units; The CPU module body supports dedicated data memory cards and batch encrypted downloads, has strong motion control and imitation control capabilities, and supports user-defined function expansion; A variety of communication modules are available to support fieldbus, wireless network and industrial Ethernet interfaces.
Key features:
Rich manipulation
The 32-bit high-performance embedded processor is selected, which has functions such as logic control, timing control, motion control, and imitation control, and supports encrypted user-defined utility blocks.
Robust development environment
The Autothink configuration programming software with independent intellectual property rights developed by Hollysys is selected to meet the IEC61131-3 specification, and has the functions of networked PLC engineering management, graphical configuration, compilation and subassembly, online simulation and debugging, etc., providing users and integrators with an easy-to-operate, easy-to-protect and more compatible programming and development environment.
|
More on that
|
Hollysys OCS industrial optical bus control system was successfully applied in Sinopec project
On November 13, 2022, Zhong'an United Coal Chemical Branch came with exciting news that the 20,000 tons/year butene-1 plant produced qualified butene-1 products at 22 o'clock on the same day, and the one-time start-up was successful. The control system of the device adopts the innovative technology product "OCS Industrial Optical Bus Control ...
|
|
Hollysys DCS - What is DCS distributed control system?
DCS is the English abbreviation of distributed control system (Distributed Control System), distributed control system is referred to as DCS, which can also be literally translated as "distributed control system" or "distributed computer control system". The decentralized control system is based on the microprocessor, and the control function is decentralized.
|
|
and Lisi plc - the difference between DCS and PLC
The choice between a programmable logic controller (PLC) and a distributed control system (DCS) is a case-by-case analysis, as the requirements for the control system vary depending on the application. You can start from the following aspects!
PLC and DCS
PLC
...
|
|
Hollysys PLC - what are the anti-interference countermeasures of PLC and touch screen?
In order to improve the anti-interference ability of the PLC system, we should start from the design. In the anti-interference design of specific projects, products with strong anti-interference ability can be selected to improve the anti-interference of equipment and systems by suppressing interference sources, cutting off or attenuating the transmission path of electromagnetic interference, and using software means.
|
|
Hollysys DCS - What are the specific contents of the major and minor repair projects of the DCS system?
(1) Overhaul projects
DCS system overhaul is carried out in the random group of main equipment overhaul, and the overhaul project includes the following:
1) Conduct a comprehensive inspection of the control equipment and make a record.
2) Copy the configuration of all modules, and verify the marks and addresses of the modules.
3) Qing ...
|
|
Hollysys debuted at the XCon2022 Security Focus Information Security Technology Summit
On September 19, 2022, the XCon2022 Security Focus Information Security Technology Summit was successfully held in Beijing. More than 10 technical experts, heads of security departments, and front-line security experts from well-known domestic network security enterprises shared in-depth topics at the meeting.
|
|
Hollysys PLC - What is the use of the PLC interrupt function?
PLC understands the interrupt function in this way, when understanding the interrupt, we must first understand the PLC operation cycle or the scanning cycle, it is necessary to say that the PLC sequential control cycle execution process, which is the premise of understanding the interrupt, must be mastered, divided into three parts, input processing, program processing, output ...
|
|
Hollysys DCS - the main factor of DCS signal interference
Resistive coupling interference
In the process of work, many factories ignore the problem of wire aging. When a variety of signal lines are transmitted together, other transmission signals will be affected due to the aging and leakage of the insulation material on the wire, and other transmission signals will be interfered with. ...
|
|
Hollysys PLC - what are the commonly used networking methods of PLC?
1 Universal serial port module
Based on the serial port communication module to realize the network connection, the network structure is shown in Figure 1, the form of computer link is adopted, the corresponding settings are carried out in the configuration software of the host computer, and the communication can be carried out with multiple PLCs without programming, and the FXlS of Mitsubishi ...
|
|
Hollysys PLC - the basic structure of PLC and the role of each part of the detailed explanation
1. Power supply: The power supply is used to convert the alternating current into the direct current required inside the PLC, and most of the PLCs are powered by switching regulated power supply.
2. Central processing unit: The central processing unit (CPU) is the control center of the PLC, and it is also the core component of the PLC.
|
|
Century Qualcomm and Hollysys reached a strategic cooperation
With the inclusion of "exploring the construction of digital twin cities" in the 14th Five-Year Plan, the field of intelligent transportation is being endowed with more new business value. Recently, Century Qualcomm and Hollysys reached a strategic cooperation, based on the principle of "giving full play to advantages, mutual promotion, long-term cooperation, mutual benefit and win-win", ...
|
|
Hollysys DCS - DCS system operation problem analysis and preventive measures
1. Communication network failure: communication network faults are generally easy to occur at the contact bus and local bus, or caused by wrong address identification.
2. Node bus failure: The transmission medium of the node bus is generally coaxial cable, some use token signal transmission mode, and some use ...
|
|
Hollysys PLC - Six Fault Types of PLC and Troubleshooting Methods (1-3)
First, the type of failure of the PLC.
1. External equipment failure.
External equipment refers to various switches, sensors, actuators, loads, etc., which are directly connected with the PLC operation process. The failure of these equipment will directly affect the control function of the PLC system. Therefore...
|
|
Hollysys DCS - the debugging scheme of DCS system
1. Check before power-on
If the cable insulation resistance meets the requirements (greater than 5M ohms), check the cable insulation resistance test record, and spot check the actual measurement if necessary.
Check that all power cables, signal cables, and communication buses should be connected.
Control stations, operator stations, engineer stations, etc.
|
|
Hollysys PLC - What are the selection methods of PLC?
1. Budget for input and output (I/O) points
When budgeting I/O points, the appropriate margin should be considered, usually based on the calculated number of input and output points, and then add 10%-20% of the expandable, and after the margin, it will be used as the budget data of input and output points. When ordering in practice, it is also necessary to rely on the manufacturer's ...
|
|
Hollysys PLC - five characteristics that become a necessary condition for high-end PLC
Since the day of the birth of PLC, it has occupied the core position of the entire automatic control system. There are also many discussions about the development direction of PLC, whether it is predicted that PAC will replace PLC from 10 years ago, or during this time, some people even say that PLC is no longer needed in the future Industry 4.0 era...
|
|
HollySys PLC - What are the design requirements that need to be met for PLC programs?
Simplicity
Make the PLC program as simple as possible. Simplicity means using a standardized procedural framework as much as possible and using simple instructions as much as possible.
If you want the program to be simple, in a big way, you should optimize the program structure, simplify the program with process control instructions, and ...
|
|
Hollysys DCS output module - K-AO02 advantages introduced
1. The output accuracy is as high as 0.05%, which greatly improves the operation efficiency of the system.
2. The full-scale output of the channel signal is 0-22.7mA, and the output range is wide;
3. It can be adapted to the enhanced base to achieve channel resistance to 220VAC;
4. It has a perfect channel signal diagnosis function, which can be realized.
|
|
The scientific and technological achievements of "SCADA system development and refined oil pipeline application based on independent chips and operating systems" have reached the international advanced level
On October 15, 2022, the scientific and technological achievement of "SCADA system development and refined oil pipeline application based on independent chips and operating systems" jointly completed by South China Branch of National Petroleum Pipeline Network Group Co., Ltd. and Hangzhou Hollysys Automation Co., Ltd. successfully passed the China Petroleum and Chemical Industry Co., Ltd.
|
|
and Nesbitt DCS - the difference between SCADA and DCS and PLC
To put it simply, DCS is mainly used for process automation, PLC is mainly used for factory automation (production lines), and SCADA is mainly for wide-area needs, such as oil fields and pipelines that stretch for thousands of miles. If from the point of view of computers and networks, they are unified, and the reason for the difference is mainly in ...
|
|