On October 15, 2022, the scientific and technological achievement of "SCADA system development and refined oil pipeline application" jointly completed by South China Branch of National Petroleum Pipeline Network Group Co., Ltd. and Hangzhou Hollysys Automation Co., Ltd. successfully passed the technical achievement appraisal organized by China Petroleum and Chemical Automation Application Association. The appraisal committee believes that the overall technology of this achievement has reached the international advanced level, among which the trusted computing technology of the whole life cycle of the industrial control system, the dual-system parallel and the deterministic real-time communication protocol technology based on the concurrent master-slave polling mechanism are at the international leading level, and unanimously agreed to pass the appraisal of scientific and technological achievements.
The domestic long-distance oil and gas pipeline control system has long adopted foreign SCADA system, and the core control technology is highly dependent on foreign countries, the cost remains high, and the supply of spare parts is not timely, which seriously affects the safety and stability of production.
The South China Branch of National Petroleum Pipeline Network Group Co., Ltd. regards the country's energy security as its corporate responsibility and mission, and has established the "Research Working Group on the Localization of Core Technology of Refined Oil Pipelines", with a number of experts and technical backbones forming a major scientific and technological research team. After a number of technical research and cooperation, and finally cooperated with Hangzhou Hollysys Automation Co., Ltd. to form a "SCADA system development based on independent chips and operating systems and refined oil pipeline application" research and development team, through the efforts of both parties, the research results have been successfully applied in Zhuhai Station and Zhongshan Station of South China National Pipeline Network Company from August 30, 2021 to September 30, 2022, and the system runs stably and reliably. The results of commissioning show that the system has surpassed similar foreign products in terms of function, performance and reliability, and can be completely replaced by localization.
This achievement has obtained 10 authorized invention patents, registered 10 national software copyrights, and formulated 4 national standards.
Hollysys' SCADA system for refined oil pipelines based on independent chips and operating systems is a 100% domestically developed control system with independent intellectual property rights, with the protection function of trusted computing and endogenous information security, and the microkernel technology can realize cross-platform operation, with advanced technology, realizing that the SCADA system is completely independent and controllable, safe and credible, reducing engineering costs, and has formed a new core competitiveness in the field of oil and gas pipelines, which will greatly improve the infrastructure safety level of oil and gas pipelines. It plays an important role in ensuring the security of national oil and gas energy.
|
More on that
|
and Lisi plc - the difference between DCS and PLC
The choice between a programmable logic controller (PLC) and a distributed control system (DCS) is a case-by-case analysis, as the requirements for the control system vary depending on the application. You can start from the following aspects!
PLC and DCS
PLC
...
|
|
Hollysys PLC - Six Fault Types of PLC and Troubleshooting Methods (1-3)
First, the type of failure of the PLC.
1. External equipment failure.
External equipment refers to various switches, sensors, actuators, loads, etc., which are directly connected with the PLC operation process. The failure of these equipment will directly affect the control function of the PLC system. Therefore...
|
|
Hollysys DCS - a common fault of DCS
1. Field instrument equipment failure:
Field instrumentation equipment includes various transmitters, various switches, actuators, loads and components of various temperatures that are directly connected with the production process. If the field instrument fails, it directly affects the control function of the DCS system and the operator's ...
|
|
Hollysys DCS - How to deal with DCS system failure?
1. View the data on the monitoring screen
When the following situations occur, it means that there is a problem with the control system, and the microcomputer maintenance personnel should be notified immediately for maintenance, and the operator should go to the site to deal with it.
(1) Frequently changing data does not change for a long time, and several or all data do not ...
|
|
Hollysys PLC - What is the use of the PLC interrupt function?
PLC understands the interrupt function in this way, when understanding the interrupt, we must first understand the PLC operation cycle or the scanning cycle, it is necessary to say that the PLC sequential control cycle execution process, which is the premise of understanding the interrupt, must be mastered, divided into three parts, input processing, program processing, output ...
|
|
Hollysys debuted at the XCon2022 Security Focus Information Security Technology Summit
On September 19, 2022, the XCon2022 Security Focus Information Security Technology Summit was successfully held in Beijing. More than 10 technical experts, heads of security departments, and front-line security experts from well-known domestic network security enterprises shared in-depth topics at the meeting.
|
|
Hollysys debuted at the 13th Berlin International Rail Transit Exhibition
On September 20, 2022, Berlin time, the 13th Germany Berlin International Rail Transit Exhibition (InnoTrans 2022) opened at the Berlin International Exhibition Center in Germany. Following the 2018 exhibition, Hollysys once again appeared at the Berlin International Railway Exhibition (hereinafter referred to as the Berlin Exhibition) ...
|
|
HollySys PLC - What are the design requirements that need to be met for PLC programs?
Simplicity
Make the PLC program as simple as possible. Simplicity means using a standardized procedural framework as much as possible and using simple instructions as much as possible.
If you want the program to be simple, in a big way, you should optimize the program structure, simplify the program with process control instructions, and ...
|
|
Hollysys PLC - the six application functions of PLC
1. It is used for switching control
The ability of PLC to manipulate switching quantities is very strong. The number of points in and out of the control, less than a dozen points, dozens of points, more can be hundreds, thousands, or even tens of thousands of points, because it can be networked, the number of points is almost unlimited, no matter how many points can be controlled, the control ...
|
|
Hollysys PLC - a component of the PLC control cabinet
1. Open empty
A master air switch that is the power control for the entire cabinet.
2. Power supply
A 24VDC switching power supply.
3、PLC
This should be chosen according to the needs of the project. If the scale of the project is small, the integrated PLC can be used directly; If the item ...
|
|
Steps on how Hollysys DCS works on a computer
1. Confirm that the new computer has relevant interfaces and can be used normally, and Hollysys DCS software can run on the computer operating system
2. Device and Lisi DCS software, dongle, and related drivers (mainly redundant network cards, data hard disks, etc.)
3. Set up ...
|
|
Hollysys DCS - the connection method between thermocouple and DCS
1. The thermocouple uses a compensation wire, and there can be a node in the middle, but the corresponding compensation cable must be used to directly connect to the DCS thermocouple module, such as the LLMUX card in HONEYWELLTPS. Minimize nodes to reduce interference. In addition, in the DCS configuration, it is necessary to select the corresponding thermocouple model, and supplement the ...
|
|
Hollysys DCS - Introduction to I/O in DCS control system
The control system needs to establish the input and output channels of the signals, which is called I/O. The I/O in a DCS is generally modular, with one or more I/O channels on one I/O module for connecting sensors and actuators (control valves).
The control unit of the DCS: a process control station is ...
|
|
Hollysys PLC - nine precautions for the use of PLC
1. PLCZ self-fault judgment
In general, PLCs are extremely reliable devices with a very low failure rate. The probability of hardware damage such as the CPU of the PLC or software running errors is almost zero; If the PLC input point is not caused by strong current intrusion, it will hardly be damaged; PLC output relay ...
|
|
Hollysys DCS - the main factor of DCS signal interference
Resistive coupling interference
In the process of work, many factories ignore the problem of wire aging. When a variety of signal lines are transmitted together, other transmission signals will be affected due to the aging and leakage of the insulation material on the wire, and other transmission signals will be interfered with. ...
|
|
Hollysys DCS - DCS system operation problem analysis and preventive measures
1. Communication network failure: communication network faults are generally easy to occur at the contact bus and local bus, or caused by wrong address identification.
2. Node bus failure: The transmission medium of the node bus is generally coaxial cable, some use token signal transmission mode, and some use ...
|
|
Hollysys released a new DCS control system
Hollysys' safe and trustworthy DCS control system uses the controller K-CU11 for the K series large-capacity trusted controller module, which adopts advanced PowerPC architecture high-performance main processor and security components based on national cryptography algorithm, and has the security functions of static trusted start and dynamic trusted measurement. ...
|
|
Hollysys DCS - DCS daily maintenance and fault analysis and troubleshooting methods
01. Power supply
The DCS power supply system is mostly a "dual backup hot redundant power supply", and the prevention and control of power failures is mainly reflected in the inspection and daily maintenance.
Generally speaking, as long as the unit is normal ...
|
|
Hollysys PLC - Electrical troubleshooting of PLC control loop
In general, PLCs are extremely reliable devices with a very low failure rate. The probability of hardware damage such as the CPU of the PLC or software running errors is almost zero; If the PLC input point is not caused by strong current intrusion, it will hardly be damaged; The normally open point of the PLC output relay, if it is not a short circuit of the peripheral load ...
|
|
Hollysys successfully signed the first 100 billion cubic meter gas field project in Bohai Bay to help achieve the "double carbon" goal
Recently, Hangzhou Hollysys Automation Co., Ltd. successfully signed the first 100 billion cubic meters of gas field project in Bohai Bay (1) - CNOOC Tianjin Branch Bozhong 19-6 condensate gas field phase I development project (hereinafter referred to as: Bozhong 19-6 project), and will provide PCS (DCS), ESD, FGS, ...
|
|