Delixi information SHOW
Delixi voltage regulator fault phenomenon Delixi voltage regulator fault phenomenon

Delixi regulator output voltmeter keeps swinging back and forth, and sparks occur at the carbon brush, and the problem phenomenon and cause analysis 1. The contact pressure between the carbon brush and the coil plane is too small 2. The carbon brush is severely worn Delixi voltage regulator has ...

Delixi relay maintenance method Delixi relay maintenance method

Relay is a kind of electrical appliance that turns on or off the control circuit according to the change of external input signals, such as electrical voltage, current) or non-electrical quantity (heat, time, speed, etc.) to complete the control or maintenance mission.

Delixi bearing rust causes Delixi bearing rust causes

1. The instantaneous high temperature in the grinding process will make the surface of the workpiece reach a molten state, and the steel surface will react with the oxygen in the air chemically, which will form a very thin (20-30nm) iron oxide film.

The cause of the failure of Delixi inverter The cause of the failure of Delixi inverter

1. Overcurrent (short circuit) Overcurrent problems are the most common in the side of various faults in the inverter. The problem is mostly due to the following problems: first, as long as the speed converter is reported when starting, it is clear that the overcurrent is very serious, and most of them are load short circuits, mechanical parts stuck, inverters...

Delixi circuit transformation attention to detail Delixi circuit transformation attention to detail

1. If strong electricity and weak electricity are to be separated by a long distance from the horizon walking line, the interval should generally exceed 30 cm to prevent disturbance and be interspersed with each other. 2. In order to facilitate the future line change, the PVC pipe must be cut down and straightened as much as possible.

The difference between Delixi soft start and inverter The difference between Delixi soft start and inverter

Features of the soft starter: The motor can be soft-started, soft-stopped, and soft-stopped. It can achieve a small impact on the machine-to-power grid. It is much smaller than the Star-Delta starter and the installation is simple. Frequency converters ...

Delixi relay maintenance method Delixi relay maintenance method

Relay is a kind of electrical appliance that turns on or off the control circuit according to the change of external input signals, such as electrical quantity (voltage, current) or non-electrical quantity (heat, time, speed, etc.), in order to complete the control or maintenance mission.

Delixi control transformer use precautions Delixi control transformer use precautions

Delixi control transformer is the most used type is BK, JBK, BKC and other types, these transformers use some precautions as follows! 1. Before purchasing, estimate the total capacity of the electrical appliances used, and choose a transformer with a certain capacity to ensure that it will not burn out when it starts instantaneously.

The cause of the abnormality of the motor controlled by the inverter The cause of the abnormality of the motor controlled by the inverter

The first method is that you can analyze what the cause is according to the condition displayed on the inverter, such as whether the faulty code appears normal, whether there is still running code or not, and still nothing appears (in the case of input power), which means that there is a rectification problem. If you're on standby...

Delixi voltage regulator fault performance and elimination Delixi voltage regulator fault performance and elimination

Regulator problem 1: The regulator cannot be started Reason: Whether the phase sequence of the input power cord has been changed, and the air switch in the machine is not turned on or broken. Repair methods: 1. Swap the two power supply wires arbitrarily or check whether the power supply line is correct; 2. Close or replace the switch. Voltage Regulator ...

Delixi inverter usage Delixi inverter usage

First of all, Delixi inverter has a very high control accuracy. It uses advanced electronic skills and digital control skills, and can control the speed, torque, and current of the motor with a high degree of control. Together, the controller of Delixi inverter also has a high overload capacity and strong ...

Delixi inverter selection principle Delixi inverter selection principle

1. According to the load type, confirm the type of inverter: different load types, speed requirements and power size, the need to choose different types of Delixi inverter. Therefore, it is necessary to understand in detail the type of motor load to be controlled in order to find the most suitable type. ...

How to adjust the output voltage of Delixi voltage regulator How to adjust the output voltage of Delixi voltage regulator

1. How to disassemble the voltage regulator Generally, there are screws on the shell of the voltage regulator, please disconnect the power supply first, and then remove all the screws on both sides to take off the shell. After the regulator shell is disassembled, the circuit, copper coil, carbon brush, etc. inside will be revealed.

Precautions for the use of Delixi stabilized power supply Precautions for the use of Delixi stabilized power supply

1. The use environment of regulated power supply requires good ventilation, no moisture, no corrosive gas, explosive substances, conductive dust Egypt steam, etc., and it is required to be installed in places without intense oscillation. ​ 2. The voltage regulator is used according to the function of the electrical equipment.

Methods for preventing breakdown of transformer insulation Methods for preventing breakdown of transformer insulation

1. Avoid water and air entering the transformer (1) The transformer should be protected from water ingress and moisture during operation, and it is necessary to seal well the cap of the casing item, the top of the storage phase, the bushing pipe and its connecting pipes. If necessary, a leak detection test should be carried out, and if the insulation has been found to be damp, it should be adopted in time.

The reason why the Delixi switch socket is hot and hot The reason why the Delixi switch socket is hot and hot

1. The quality of the socket is low First of all, we should check whether the socket is a miscellaneous defective product, the copper clamping force in the defective socket is not enough, resulting in a poor connection between the socket and the plug, and the socket and plug will heat up after a long time of electrical use. Therefore, you must not buy cheap miscellaneous electric ...

The difference between an isolation switch and a circuit breaker The difference between an isolation switch and a circuit breaker

The circuit breaker has arc extinguishing equipment, so the circuit breaker can be operated with load, not only the load current, but also the fault (short circuit) current; The circuit breaker has a good package form, so simply observing the circuit breaker cannot intuitively determine whether it is in the closed or disconnected position. Isolate ...

Introduction to the closed-loop control system of stepper motor Introduction to the closed-loop control system of stepper motor

1. The closed-loop control of the stepper motor was first in the form of encoder For stepper motors with low split ratio, a slotted disc and photoelectric sensor are usually used as a reaction encoder assembly, and the number of notches is equal to the number of steps taken by the motor per revolution, · About high resolution ...

Linear and switching regulator features Linear and switching regulator features

The advantages of linear DC regulator are high stability, small ripple, high reliability, and easy to make a multi-output connected adjustable power supply. The disadvantages are large size, bulkiness, and relatively low power. There are many kinds of this kind of regulated power supply, which can be divided into regulated power supply, stabilized current power supply and ...

Delixi solid state relay introduction Delixi solid state relay introduction

What is a Solid State Relay Solid State Relay (SSR) is a pointless switch composed of microelectronic circuits, discrete electronic devices, and power electronic power devices. The barrier between the control end and the load is completed by a barrier device. The input of the solid state relay is micro...

Delixi anti-leakage is different from ordinary circuit breakers Delixi anti-leakage is different from ordinary circuit breakers

Circuit breaker refers to a switchgear that can close, carry and break the current under normal circuit conditions, and can close, carry and break the current under abnormal circuit conditions within a specified time. Circuit breakers can be used to distribute electrical energy, infrequently start asynchronous motors, and ...

Next Page »
CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top