The difference between a Hitec display and a touch screen

Create Date: 2024-8-30 12:03:23|Source: Hitec/HITECH

Outsiders often misunderstand this kind of term, taking the common computer display screen as an example, it is only a kind of display screen, and its structure is basically the same as that of the mobile phone screen except for special models.

The display structure used by most computer monitors does not contain a touch screen and does not have a touch function, and this kind of display screen is classified as an output device and a display device;

The display screen with touch function, although it is still a display screen, has an additional touch function, and the screen structure layer responsible for providing the touch function is called the touch screen;

In the process of daily use, people will directly use "display" to depict the display screen, and "touch screen" is used to depict the display with a touch screen;

But in fact, this kind of display uses a "touch display", which provides output and imaging functions, and also includes touch functions, so many people misunderstand that it is attributed to output devices.

                               The difference between a Hitec display and a touch screen

More on that
Hitec touch screen new and old models replacement selection Hitec touch screen new and old models replacement selection

Hitec touch screen selection: 10.4" Series: PWS6A00T-N (True Color Network), PWS6A00T-P (True Color Enhanced), PWS6A00T-S (Color Basic) 7.5" Series: PWS6800C-N ...

Analysis of the crash situation of the human-machine interface - Hitech Analysis of the crash situation of the human-machine interface - Hitech

The human-machine interface (mainly the operation station) crashes all DCS exist to varying degrees, only with different degrees of frequency. It is also related to the length of time that DCS is used. Crash caused by hardware, showing that it can no longer recover. If the power supply voltage of the operation station is low, it is easy to make the operation station crash. Cause...

Guidelines for designing industrial touch screens – Hitech Guidelines for designing industrial touch screens – Hitech

The industrial touch screen is an intelligent interface that connects people and machines through touch industrial displays. It is an intelligent operation display terminal that replaces the traditional control buttons and indicator lights. It can be used to set parameters, display data, monitor equipment conditions, draw curves/animations, etc.

Resistance touch screen non-response detection method - Hitech Resistance touch screen non-response detection method - Hitech

1) Check whether the connection of the touch screen is right, and whether the connection of a cable connected to the keyboard port of the host (take the working voltage of the 5 volt touch screen from the keyboard port) is connected, please check the connection. 2) Observe the situation of the touch screen controlling the box light, if ...

Hitec touch screen calibration method Hitec touch screen calibration method

(1) After the terminal is turned on, find out whether each calibration teaching file is not clicked in the execution step (2) If it exists, perform the step (4); (2) After the boot is finished, the active high-motion is the quasi-program, prompting the user to calibrate the touch screen, after the calibration is completed, the touch screen driver ...

Hitec touch screen daily simple maintenance tips Hitec touch screen daily simple maintenance tips

1. In the daily use of the equipment, try to prevent frequent power off and off, and sudden power failure during operation will cause certain damage to electronic components and hard disk errors; In terms of power supply, keep operating in a stable voltage environment, too low voltage, too high voltage will affect the function of the equipment, and will also ...

Analysis of the advantages and disadvantages of Hitec capacitive touch screen Analysis of the advantages and disadvantages of Hitec capacitive touch screen

The light transmittance and clarity of the capacitive contact screen are better than those of the four-wire resistive screen, and of course, it cannot be compared with the external acoustic wave screen and the five-wire resistive screen**. The reflection of the capacitive screen is severe, and the transmittance of the four-layer composite contact screen of the capacitive skill to each wavelength of light is uneven, and there is a problem of color distortion, ...

What is the standard for the operation of the touch screen - Hitech What is the standard for the operation of the touch screen - Hitech

The touch screen must be clear, responsive and stable to be the standard contact display. Tests that can be performed on your own Use the checker provided in the driver to check the physical function of the contact screen ...

How to duplicate the program on two Hitec touch screens How to duplicate the program on two Hitec touch screens

TWO HITECH TOUCH SCREEN COPY PROGRAM METHODS: 1. Make a communication cable first. HMI1 COM port HMI2 COM port 25-pin female 25-pin female   ​   RXD 3 ...

Hitec touch screen decompilation method Hitec touch screen decompilation method

1. The small switch at the back of the touch screen, DIP5, 6off, can enter the system catalog of the touch screen. 2. Select the download/UP load copy port of the man-machine as com1, and go to configure to select. ...

Common faults of Hitec touch screens Common faults of Hitec touch screens

1. Observe the signal indicator of Hitec touch screen, the light flashes regularly under normal circumstances, about once per second, when touching the screen, the signal light is always on, and after stopping the touch, the signal light resumes flashing. 2. If the signal light is not touched, it is still at ...

What is the technical principle of Hitec touch screen? What is the technical principle of Hitec touch screen?

The touch screen senses the contact of our fingers because when the finger touches a specific direction on the screen, it is equivalent to sending a precise electronic signal to the screen. There are many types of contact screens, which are broadly divided into resistive contact screens and capacitive contact screens. Now the most widely used is "electricity...

The working principle of the five-wire resistive touch screen - Hitech The working principle of the five-wire resistive touch screen - Hitech

The four ends of the touch screen RT, RB, LT, LB four poles, all participate in a uniform electric field, so that the lower layer (indium oxide) ITO GLASS is covered with a uniform voltage, the upper layer is the receiving signal device, when the pen or finger presses any point on the surface, at the finger press, the controller ...

The defect of the capacitive touch screen - Hitec The defect of the capacitive touch screen - Hitec

The light transmittance and clarity of the capacitive contact screen are better than those of the four-wire resistive screen, and of course it cannot be compared with the external acoustic wave screen and the five-wire resistive screen. The capacitive screen is severely reflective, and the four-layer composite contact screen of the capacitive skill has a strong impact on each wavelength ...

Hitec Industrial HMI Functions and Selection Points Hitec Industrial HMI Functions and Selection Points

Basic Functions: Display of equipment working status: such as indicator lights, buttons, text, graphics, curves, etc.; Data and text input operations, printouts; Production formula storage, equipment production data recording; simple logical and numerical operations; Can...

The reason for the failure of industrial touch screens - Hitech The reason for the failure of industrial touch screens - Hitech

After clicking on the three corners of the contact screen, enter the offline form (note: different contact screens enter the offline form in different ways). Once in the offline format, click "INITIALIZE", and after clicking, keep clicking "SET-UP-I/O" and then "SET-UP-TOUCH-PANEL". ...

Common faults of Hitec touch screen and their maintenance methods Common faults of Hitec touch screen and their maintenance methods

(1) Fault 1: Contact deviation Phenomenon 1: The direction of the finger does not coincide with the mouse arrow. Reason 1: After installing the driver, there is no vertical contact with the bullseye when calibrating the alignment. ...

Lightning impulse control system requirements for industrial touch film screen - Hitech Lightning impulse control system requirements for industrial touch film screen - Hitech

1) The general requirements of the lightning impulse control system for the industrial touch film screen 1.1. Use the big button as a brief click interface; 1.2. Run your application in full screen; 1.3. Use bright scenery colors (don't use black); 1.4. Make the user touch ...

Touchscreen usage skills - Hitec Touchscreen usage skills - Hitec

1. Run your app in full screen Remove the file name bar and menu bar so you can enjoy the benefits of running the entire screen. 2. Choose bright colors (don't use black) The bright color of the set can hide the finger prints, reduce the dazzling light and star...

The PLC and touch screen interact consistently The PLC and touch screen interact consistently

When the touch screen is connected with the PLC, in fact, the memory of the PLC is used, (the touch screen also has a small amount of memory, which is only used to store system data, that is, the screen, controls, etc.), the touch screen and the PLC communication is generally the master/slave contact, that is, the touch screen reads the data from the PLC, and the judgment is made in the display ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top