Rittal Blue e+ cooling unit in the cooling of the Airbus A320 test plant
A new A320 Airbus aircraft must pass rigorous testing before it can be put into service, so to ensure a smooth flight, not only the aircraft itself needs to be protected from overheating, but also the test hardware needs to be properly protected. Airbus uses Rittal Blue e+ cooling units to make it ...
|
|
Rittal cables – the difference between power cables and control cables
The power cable is used to transmit and distribute large-scale electrical energy in the main line of the power system, and the control cable directly transmits the electric energy from the distribution point of the power system to the power connection line of various electrical equipment and appliances. The rated voltage of power cables is generally 0.6/1KV and above, and the control cables are mainly 4 ...
|
|
A detailed assortment of Rittal products
Rittal's products are: Rittal control cabinets: small cabinets (polycarbonate cabinets PK, junction boxes KL, compact control boxes EB, bus cabinets BG), compact control cabinets, plastic control cabinets KS, cabinet systems (subdivided into TS 8/SE 8 family), parallel cabinet systems...
|
|
Rittal Cabinet - Knowledge Quiz of High and Low Voltage Distribution Cabinet (51-60)
51 What are the factors that affect the degree of harm to the human body caused by electric shock?
Answer: Factors such as the magnitude of the current, the duration of the current, the path of the current, the resistance of the human body and the frequency of the current.
52 Types of electric shock?
Answer: Direct electric shock, indirect electric contact, inductive ...
|
|
Rittal Cables – an introduction to the structure of industrial control cables
1. Conductor
It is the main component of the product to play its use function, and it is to transmit electricity or information, that is, to transmit electric current or electromagnetic waves on the conductor. The conductor is the basic and indispensable main component of the product for the transmission of electric current or electromagnetic wave information.
2. Insulation ...
|
|
What are the main problems in the practical application of Rittal cabinet air conditioners on the client?
Through continuous big data analysis of 200,000 cabinet air conditioners installed and operated on the market, Rittal found that the main problems in the actual application of air conditioners on the client are as follows:
1. Lack of maintenance, resulting in clogged air conditioner filters, which in turn causes the air conditioner to stop running or ...
|
|
Rittal cabinet - the introduction and function of network cabinets
What is a Network Cabinet?
The network cabinet is a kind of rectangular cabinet composed of two parts: frame and cover, which can install switches, optical fiber adapters, optical fiber distribution frames and other equipment in a cabinet, with electromagnetic barrier, noise blocking, ventilation and heat dissipation, anti-vibration, anti-corrosion, etc.
|
|
Rittal at the Hannover Messe 2022 in Germany
"In 2022, with all the challenges, especially for small and medium-sized manufacturing companies – we need to think differently: if we want to support our customers and add value in our digital transformation, it's not just a single product innovation that will change. It will combine automation, digital ...
|
|
Analysis of the causes of the alarm code of the Rittal cabinet and how to deal with it
A01--- Rittal cabinet control cabinet door opens
View: Look at the door switches in the Rittal cabinet.
Solution:
(1) Adjust the position of the door switch.
(2) Check whether the wiring method is correct (passive normally closed point at 1.2 points).
A03 --- Filter Monitor ...
|
|
Rittal cabinets – what electrical components are included in the electrical cabinet?
1 Circuit breaker
Low-voltage circuit breakers, also known as automatic air switches, can be switched on and off manually, and can be used to distribute electrical energy, start asynchronous motors infrequently, and protect power lines and motors. In the event of a severe overload, short circuit, or undervoltage fault, the circuit can be automatically shut down.
2 Contactors
...
|
|
Rittal presents a number of green and innovative sanitary cabinets at CBST
On April 7, 2023, the 11th CBST China International Beverage Industry Technology Exhibition was grandly held at the Shanghai New International Expo Center.
As a practitioner of the concept of "intelligent manufacturing" in Germany, Rittal brings many green and innovative sanitary cabinet systems and temperature control solutions.
|
|
Rittal fans – analysis of the reasons why cooling fans do not rotate
1. Power failure: The power supply of the fan fails, such as the power cord is disconnected, the power plug is loose, etc., which will cause the current to fail to transmit normally, resulting in the fan stopping and rotating.
2. The temperature is too low: Some heat dissipation windbreakers have a temperature protection function, when the temperature is too low, the fan will automatically ...
|
|
Rittal cabinets – an introduction to the installation steps and features of the control cabinet
The control cabinet is according to the requirements of electrical wiring to assemble switchgear, measuring appearance, maintenance appliances and auxiliary equipment in a closed or semi-closed metal cabinet or screen panel, and its arrangement should meet the requirements of the normal operation of the power system, easy to overhaul, and not to endanger the safety of people and surrounding equipment. Normal operation ...
|
|
Rittal's enclosure – seven common faults in the distribution cabinet and their failure analysis
1. The circuit breaker cannot be closed
Causes:
1. The undervoltage coil does not work (the voltage is normal). Solution: Replace the undervoltage coil.
2. Press the closing button, and the closing coil will not work when it is powered up. Solution: Replace the undervoltage coil.
3. Cooperation...
|
|
Common faults and troubleshooting methods of oil coolers - Rittal cabinets
Fault symptom 1: insufficient cooling capacity
Cause analysis
(1) The room or box is not sealed or the thermal insulation performance is poor
(2) The evaporator frost is too thick
(3) The efficiency of the compressor deteriorates
(4) The expansion valve is too large or too small
(5) There are more ...
|
|
Rittal cables – the types of cables in detail
Flame retardant rubber sheathed cable
1. Use
This product is a series of mining rubber sheathed flexible cables. It is suitable for power connection of shearers and similar equipment devices with rated voltage Uo/U of 1.9/3.3KV and below. It is mostly used in coal mines.
2. Conditions of use
Long-term core ...
|
|
Running seamlessly, Rittal develops with reliable quality "pulsating" energy storage
Reliable supply wherever you are
Tesvolt's large-scale industrial battery storage systems are based on standard products made by Rittal and guarantee a continuous power supply on the top of a mountain, by the sea or in the desert.
The mountain peaks rise high above the crystal clear ...
|
|
Some precautions should be taken in the installation and setting of Rittal air conditioning
The arrangement of the electronics in the cabinet
Note:
Condensation is dangerous! When the electronics are arranged in a Rittal cabinet, the cold air from the air conditioner must not flow directly to the live device. Cold air must not be allowed to flow directly to a hot exhaust gas stream from a live device such as a frequency converter. Because this will lead to ...
|
|
Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets
What are the basic requirements for a high-voltage circuit breaker?
A: A. Reliable work;
B. Have sufficient circuit breaking capacity
C. Have the shortest possible cut-off time;
D. Simple structure and low price.
What is the purpose of the disconnector?
Answer: A. Electrical...
|
|
Rittal cabinets – maintenance rules for network cabinets
1. Once a month (8 hours at the end of the month), and make a maintenance record.
2. Clean the gears of the whole machine to ensure the cleanliness and normal clearance of the gears.
3. Check the gap between the two gears at the punching device of the processing department and adjust the clearance.
4. Adjust the gap between each ink roller to ensure that ...
|