The reason for the humming sound after the motor plus the frequency conversion governor - Senlan

Create Date: 2024-8-30 12:03:23|Source: Hope Sunland

The so-called "hum" sound, that is caused by the frequency converter output waveform carrier frequency, generally if the frequency converter you use is a fixed carrier, at the moment the motor is screaming, the human ear stimulation is relatively large, then you can adjust the carrier frequency (the inverter skills manual function table has this function parameter).

                              The reason for the humming sound after the motor plus the frequency conversion governor - Senlan

The higher the carrier frequency, the smaller the sound, but the higher the carrier wave, the easier it is for the motor to generate heat. Therefore, it is necessary to consider the carrier frequency you use according to the heating program and the sound emitted, which is generally the most suitable carrier frequency at the rated current when leaving the factory, and you generally do not need to change it!

If the inverter uses a random carrier, the "hum" sound emitted by the motor will be softer, but the sound will generally be better than the sound of the fixed carrier. If you can't bear it, or if you want to run silently, you can also turn the carrier frequency up until you're satisfied.

More on that
Heat dissipation method of small-capacity inverter - Senlan Heat dissipation method of small-capacity inverter - Senlan

Natural heat dissipation methods are generally used for heat dissipation of small-capacity inverters, because their operating environment should be well ventilated and free of dust and floating objects. The dragging objects of this type of inverter are mostly household air conditioners, CNC machine tools, etc., and the power is small. ​ ...

Hope for an application example of Sunland inverter Hope for an application example of Sunland inverter

Industrial process control: It is expected that Sunland inverters are widely used in industrial process production control, such as conveyors, tugboats, air compressors, pumps, and fans and other equipment in various control systems. Mechanical control: It is expected that Sunland inverters are widely used in mechanical control, such as ...

The main step of inverter debugging - Sunland inverter The main step of inverter debugging - Sunland inverter

Investigation of the function of the inverter system Before debugging the frequency converter, it is necessary to carefully read the operation instructions and related information of the inverter to be debugged to understand the application environment and precautions. Especially before the inverter is energized, it is necessary to carefully observe and see if the inverter has obvious problems.

Senlan has won a number of awards in the inverter industry Senlan has won a number of awards in the inverter industry

On December 10, 2014, the inverter branch of China's electrical appliance industry association and the national inverter speed regulating equipment standardization skills committee professional annual meeting was held in Shanghai, 120 representatives from more than 80 professional enterprises attended the meeting, and expected Senlan to also serve as the vice chairman of the inverter branch ...

It is hoped that Sunland inverter will help enterprises produce sustainably It is hoped that Sunland inverter will help enterprises produce sustainably

With the rapid development of the national economy, the installed capacity of captive power plants and the planning of transmission and distribution networks have been expanding. After the power system fails, if the power supply cannot be quickly restored, it will cause huge economic losses and severe social impact. How to ensure the safety and stability of the enterprise, long-term production ...

Inverter control motor speed method - Senlan Inverter control motor speed method - Senlan

1. Why can the rotation speed of the motor be changed freely? The unit of motor rotation speed: r/min the number of rotations per minute, can also be expressed as rpm. Example: 2-pole motor 50Hz3000 [r/min] 4-pole motor 50Hz1500[r/min] Conclusion: The rotation of the motor ...

Analysis of soft start technology of asynchronous motor - Senland Analysis of soft start technology of asynchronous motor - Senland

The thyristor communicates the voltage regulation and soft starts The communication and voltage regulation soft engine of the thyristor is mainly to change the connection method of the thyristor, and the traditional connection method is changed to connect to the three windings, so that the power supply of the thyristor is completed by the method of parallel connection. Thyristor soft starters have a strong ...

Senlan identifies the fault place of the inverter Senlan identifies the fault place of the inverter

How to distinguish where the inverter is wrong? Step 1: Static data checking 1. Check the inverter circuit The red watch rod is received to the P end, and the black watch rod is separated from U, V, and W, and there should be a resistance value of tens of ohms, and the resistance value base of each phase, the same, the opposite should be infinite.

What is the fault of the hope Sunland inverter Er0UE? What is the fault of the hope Sunland inverter Er0UE?

ER. The meaning of the OUE fault code is: overvoltage during standby. The possible reasons are: 1. DC bus voltage detection circuit failure; 2. The input voltage is abnormal or the power is lost during operation. It can detect whether the power supply voltage used by the inverter is normal, and in addition, it is necessary to check whether the power supply line of the inverter is ...

The remote control of the inverter meets the function - Sunland inverter The remote control of the inverter meets the function - Sunland inverter

In general, the long-distance operation of the frequency converter requires the following functions: 1) Long-distance setting, if the parameters only need to be set for the first time, and do not need to be adjusted during operation, then long-distance setting is not required. 2) Long-distance start-stop, long-distance start or stop inverter, and ...

Misunderstandings and solutions to the disadvantages of inverter application - Sunland inverter Misunderstandings and solutions to the disadvantages of inverter application - Sunland inverter

Myth: The inverter selection only needs to consider the load power When purchasing a frequency converter, many users usually only match the capacity of the frequency converter based on the power of the drive motor. In fact, the load driven by the motor is different, and the requirements for the inverter are also different. ...

The reason why the frequency of the inverter cannot be adjusted - Senlan inverter The reason why the frequency of the inverter cannot be adjusted - Senlan inverter

If there is no damage to the hardware, the maximum torque output of the inverter is generally less than the load to increase the torque. The acceleration time is too short ...

Inverter maintenance method - hope sunland Inverter maintenance method - hope sunland

1. Look After taking over a faulty inverter, remove the inverter shell and clean it up, and carefully investigate the appearance, shape, and integrity of the relevant components on the circuit board with both eyes according to the type of inverter fault. This method is about charging resistors, filter electrolytic capacitors, IG ...

How to carry out frequency conversion of frequency converter - Senlan How to carry out frequency conversion of frequency converter - Senlan

(1) Rectifier. As one of the most important components of the inverter, the rectifier can convert the AC power into direct current. Its working method is more common to that of a battery charger or arc welder. It uses a diode bridge to limit the communication sine wave to only one direction.

The difference between strong and weak inverter - Sunland inverter The difference between strong and weak inverter - Sunland inverter

The inverter includes a rectifier circuit and an inverter circuit, and the input communication electricity is converted into DC voltage through the rectifier circuit and flat-wave circuit, and then through the difference between strong and weak current, it is mainly reflected in the different uses. Strong electricity is used as a kind of power power, and weak electricity is used for information transmission. In detail ...

The main circuit of the inverter application - Hope Sunland The main circuit of the inverter application - Hope Sunland

There is a circuit breaker QF and a communication contactor KM between the power supply and the inverter, when the inverter does not need to be used for a long time. or when the equipment is overhauled, the circuit breaker is used as an isolation switch, which can block the power supply and ensure the safety of maintenance. It has maintenance functions such as overcurrent and undervoltage. The main power of the inverter ...

Inverter overcurrent protection solution - Senlan Inverter overcurrent protection solution - Senlan

1. Causes of overcurrent There are many reasons for the occurrence of overcurrent, including soft and hard problems. 1. Causes of soft failures When the acceleration or deceleration time in the inverter parameters is set too short, and the motor power is heavy, it means that in the acceleration, the inverter's ...

Advantages of choosing a frequency converter Advantages of choosing a frequency converter

Advantage 1: Energy saving The motor adopts frequency converter speed regulation, and its power can be improved by 5%-10%. The inverter accounts for 20%-30% of the total capacity of the communication motor in the drag of load equipment such as fans, pumps, extruders, mixers, etc., which has a significant energy-saving effect, because the consumption of the fan and water pump is significant.

Servo motor regular diagnosis and repair method - Senlan Servo motor regular diagnosis and repair method - Senlan

1. Common faults of motor heating up too high or smoke motor Causes: 1. Excessive load; 2. Two-phase operation; 3. Blocked air duct; 4. The working temperature is too high; 5. Interphase or inter-turn short circuit fault of motor stator winding; 6. Motor stator winding grounding device; 7. The power supply voltage is too high or too low; Overhaul...

Measures to prevent overvoltage of inverter - Sunland inverter Measures to prevent overvoltage of inverter - Sunland inverter

Depending on the cause of overvoltage, the countermeasures adopted are different. Regarding the overvoltage phenomenon that occurs in the parking process, if there is no special requirement for the parking time or direction, then the extension inverter deceleration time or free parking method can be selected to solve it. The so-called free parking ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top