Introduction: The Rosemount/Rosemount electromagnetic flowmeter is 8705240, with an all-welded construction that provides an airtight port to effectively protect against moisture and contaminants, while the junction box is removable and replaceable for easy field service.
Features:
For maximum protection, an all-welded sensor housing is provided with a closed seal
Use a removable, replaceable terminal block to avoid process downtime and enable on-site repairs
There is also an optional secondary containment around the electrode to provide information on any potential process fluid leaks
Fully welded sensor housings ensure reliable performance in the harshest environments
With the optional lining protector, installation damage and leading edge wear are prevented.
The unobstructed design with no moving parts minimizes the need for maintenance and repairs
Product parameters
Accuracy: Up to 0.15% volumetric flow accuracy at 13:1 and 0.25% at 40:1
Caliber: 1/2-36 in (15-900 mm)
Lining materials: PTFE, ETFE, PFA, Polyurethane, Neoprene, Linatex natural rubber
Our customer-centric service concept: the pursuit of a full range of services is a high-quality, high-standard service, the pursuit of every detail of the service process. It is impossible for interests to blossom into brilliant flowers from lies. Only every process, every action, and every detail of the service can be professional and careful, in order to meet or even exceed customer expectations, so that customers are satisfied and recognize us. Honest, professional, affordable, fast, so let you rest assured." Integrity and professional service, affordable price, and continuous improvement" is our service concept.
This article introduces the Rosemount/Rosemount electromagnetic flowmeter 8705240 products, if you are interested in Rosemount/Rosemount sensor, please also contact our customer service, we look forward to your call, hope our technology and service can bring you a better experience.
|
More on that
|
Rosemount/Rosemount Liquid Ultrasonic Flow Meter USM381418
Introduction: The Rosemount/Rosemount Liquid Ultrasonic Flow Meter USM381418, a new custody transfer meter with excellent linearity over the flow range, further reducing product loss and unidentified loss. A new generation of electronics optimizes the operation of the flow meter, and the full-bore design ensures that the flow meter is ...
|
|
Rosemount/Rosemount Ultrasonic Flow Meter USM341810
Introduction: Rosemount/Rosemount Ultrasonic Flow Meter USM341810, the new Rosemount 3418 Octal Ultrasonic Flow Meter is manufactured, developed, and engineered by Emerson to deliver high accuracy and best-in-class performance with the high functionality required by precision legal-for-trade users. 3418 Flow Meter ...
|
|
Rosemount In-Line Oxygen Analysis, Oxymitter™ 4000, protocol, 4-20mA
Introduction: The Rosemount/Rosemount In-Line Oxygen Analysis Oxymitter™ 4000 is the world's first in-line zirconia oxygen analysis transmitter for flue gas measurement, up to explosion-proof level. These oxygen content measurements are available ...
|
|
Rosemount/Rosemount General Purpose pH/ORP Sensor 389
Introduction: Rosemount/Rosemount General Purpose pH/ORP Sensor 389, The Rosemount 389 pH/ORP sensor with integrated cable uses a molded Tefzel™ body and Viton™ O-rings to make it extremely difficult to damage and highly chemically resistant. Encapsulation eliminates the need for additional pH/O ...
|
|
Rosemount/Rosemount Hygienic Electromagnetic Flow Meter Sensor 8721010 1/2-4in tubing
Description: Rosemount/Rosemount Hygienic Electromagnetic Flowmeter Sensor 8721010 designed for food, beverage, and life science applications. All contact surfaces are manufactured using FDA-approved materials and are designed to meet 3A and EHEDG standards.
Features:
Light...
|
|
Rosemount/Rosemount Hygienic Electromagnetic Flowmeter Sensor 8721005
Description: Rosemount/Rosemount Hygienic Electromagnetic Flowmeter Sensors 8721005 Designed for Food, Beverage, and Life Sciences applications. All contact surfaces are manufactured using FDA-approved materials and are designed to meet 3A and EHEDG standards.
Features:
Light...
|
|
Rosemount/Rosemount Two-Channel Liquid Ultrasonic Flow Meter USM381214 Pressure 0-155 Bar
Introduction: The Rosemount/Rosemount Two-Channel Liquid Ultrasonic Flow Meter USM381214, two-channel design, field-replaceable sensor, high accuracy and repeatability of measurement results, suitable for verification metering, distribution, leak detection, pipeline balancing, process measurement, and other non-trade transactions.
|
|
The Rosemount/Rosemount Temperature Transmitter 3144P outputs 4-20mA
Introduction: The Rosemount/Rosemount Temperature Transmitter 3144P, Rosemount X-well technology accurately measures internal process temperatures without the need for thermowelling or process perforation. Process temperatures can be safely recorded without cutting pipes and flow frequencies or process shutdowns can be calculated. Convert each temperature ...
|
|
Rosemount/Rosemount Vortex Flow Meter 8800DR140 with a turndown ratio of 38:01:00
Description: The Rosemount/Rosemount Vortex Flow Meter 8800DR140, an integrated diameter gauge that accurately measures lower flow rates and maintains the same surface spacing as standard flanged vortex gauges.
Features:
Intelligent reducer design improves low flow measurement ...
|
|
The Rosemount/Rosemount Pressure Transmitter 3051S Wireless Coplanar™ has a 200:1 turndown ratio
Description: The Rosemount/Rosemount Pressure Transmitter 3051S Wireless Coplanar™ uses patented coplanar technology and a scalable platform combined with a secure WirelessHART® network to provide the best wireless solution for pressure, flow, and level measurement. This transmitter ...
|
|
Rosemount/Rosemount Advanced Sonic Gas Ultrasonic Flow Meter USM341730
Description: The Rosemount/Rosemount Advanced Sonic Gas Ultrasonic Flow Meter USM341730 that leverages the power of a field-proven, United Kingdom-designed Rosemount four-channel string meter (OIML R137 1&2 accuracy class 0.5) designed by Towngas, combined with ...
|
|
Rosemount Chlorine Sensor 499ACL Measuring range 0-10mg/L
Introduction: The Rosemount Chlorine Sensor 499ACL, the 499ACL is a diaphragm-covered current sensor family that can be used to measure residual chlorine, total chlorine, and monochloramine. The residual chlorine sensor 499ACL-01 requires no sample preparation or expensive reagents for maintenance. Total Chlorine Sensing ...
|
|
Rosemount/Rosemount Electromagnetic Sensor MS060 Accuracy±0.25%
Introduction: The Rosemount/Rosemount electromagnetic sensor MS060, MS slurry sensor is a reliable solution for difficult-to-measure applications such as grit, high solids fluids, long fiber slurries, or installations that generate excessive process noise. The MS slurry sensor is designed for difficult-to-measure...
|
|
Rosemount/Rosemount Continuous Gas Analyzer CT5800 Weight 85kg
Introduction: Rosemount/Rosemount Continuous Gas Analyzer CT5800, Emerson's Rosemount CT5800 Continuous Gas Analyzer is the first quantum cascade laser designed specifically for industrial process applications requiring Class I, Class 2 hazardous area certification. The CT5800 in a fireproof enclosure has ...
|
|
Rosemount Electromagnetic Flowmeter 8750W030 Caliber 4-200mm
Description: The Rosemount/Rosemount Electromagnetic Flowmeter 8750W030, with its reliable, all-welded coil housing and lightweight sensor design (IP68 rating) ensures that the meter is compatible with all utility, water and wastewater applications. Certified for drinking water.
Product Features ...
|
|
Rosemount/Rosemount Electromagnetic Flowmeter Sensor 8705060 15-900mm diameter
Description: The Rosemount/Rosemount electromagnetic flowmeter sensor is 8705060 all-welded construction with an airtight port that protects against moisture and contaminants, while the junction box is removable and replaceable for easy field service.
Features:
For added protection, it is equipped with a full ...
|
|
Rosemount/Rosemount Wireless Discrete Dual Input Transmitter 702 Materials: Low copper, aluminum, or stainless steel
Introduction: The Rosemount/Rosemount Wireless Discrete Dual Input Transmitter 702 is a cost-effective, ready-to-install unit that provides two inputs. With the safety and reliability of WirelessHART® technology, the transmitter provides access to the ...
|
|
Rosemount/Rosemount Level Switch 2110 Operating Pressure: -3.62—1450 psi
Introduction: Rosemount/Rosemount Level Switch 2110, The Rosemount 2110 Level Switch provides reliable level detection and reduces the need for maintenance for measurements in tight spaces and pipelines. Level applications and basic spill protection can be installed simply and quickly. Compliance with hygienic certifications, expanding the ...
|
|
Rosemount/Rosemount pH/ORP Sensor 398 Measuring range pH 0—14
Description: The Rosemount/Rosemount pH/ORP Sensor 398 features a Tefzel® and titanium chemically resistant construction and a patented TUpH™ reference wet, making it an ideal sensor for measuring the pH of demanding process liquids. This sensor is used to measure acid water strippers, ...
|
|
Rosemount/Rosemount Flow Meter 3051CFA Annubar™
Introduction: The Rosemount/Rosemount Flow Meter 3051CFA Annubar™, the Rosemount 3051CFA Annubar Flow Meter is an industry-leading flow measurement solution that uses a patented T-shaped average pitot tube to provide reliable accuracy across a wide flow range. Obtain...
|
|