Description: The Rosemount/Rosemount Two-Channel Liquid Ultrasonic Flow Meter USM381214, two-channel design, field-replaceable sensor, and high accuracy and repeatability for verification metering, dispensing, leak detection, pipe balancing, process measurement, and other non-custody transfer applications.
Features:
Reduce sensitivity to flow profile, solids, and/or gas entrapment changes with ultra-fast Rosemount 3810 Series electronics
Use the integrated MeterLink™ software to monitor flow analysis and display a visual view of how the flow meter is working
Use predictive diagnostics and process variable information to detect problems and avoid process exceptions and fault downtime
Wear and tear on moving parts is avoided and maintenance time and costs are reduced
Use field-replaceable, non-wetted sensors for maintenance
Simplify design and installation by widening the flow range and enhancing bi-directional flow capabilities
Adopt the new Type 4 CPU module (with up to 6 frequency or digital outputs) to increase inputs/outputs
Product parameters
Linearity: ±0.3% of measured value over a range of 1.2 to 12.2 m/s (4 to 40 ft/s)
Repeatability: ±0.10% of measured value
Speed: 1.2 to 12.2 m/s (4 to 40 ft/s) nominal and 0.3 to 14.6 m/s (1 to 48 ft/s) extended
Operating temperature range:
Sensor: -50°C to +150°C (-58°F to +302°F), depending on material selection
Electronics: -40 to +60°C (-40 to +140°F)
Operating pressure range: 0 to 155 Bar (0 to 2250 psig)
Material: carbon steel and stainless steel
Calibration: Calibration is performed in an ISO 17025 accredited Emerson flow calibration laboratory
Our customer-centric service concept: the pursuit of a full range of services is a high-quality, high-standard service, the pursuit of every detail of the service process. It is impossible for interests to blossom into brilliant flowers from lies. Only every process, every action, and every detail of the service can be professional and careful, in order to meet or even exceed customer expectations, so that customers are satisfied and recognize us. Honest, professional, affordable, fast, so let you rest assured." Integrity and professional service, affordable price, and continuous improvement" is our service concept.
This article introduces the USM381214 products of Rosemount/Rosemount Dual Channel Liquid Ultrasonic Flow Meter, if you are interested in Rosemount/Rosemount Ultrasonic Gas Leak Detector, please also contact our customer service, we look forward to your call, hope our technology and service can bring you a better experience.
|
More on that
|
Rosemount/Rosemount vortex flowmeter 8600DF030 outputs 4-20mA
Description: The Rosemount/Rosemount Vortex Flow Meter 8600DF030 product is optimized and cost-effective for general flow metering as well as clean fluid applications including steam, air, water, and nitrogen.
Features:
No moving parts, no repairs and maintenance ...
|
|
The Rosemount/Rosemount plunger probes the discrete transmitter 702 in place
Introduction: The Rosemount/Rosemount Plunger in Place Probe Discrete Transmitter 702, the Rosemount 702 Plunger Probe Discrete Transmitter uses a plunger to improve the efficiency of natural gas well sites. The transmitter is used in conjunction with an existing plunger in place sensor to detect a buggy event and send back a ...
|
|
Rosemount/Rosemount Nuclear Transformer Connector 356
Introduction: Rosemount/Rosemount Nuclear Transformer Connectors 356 Rosemount 356 Nuclear Transformer Connectors are engineered to assemble the Rosemount 3152K Nuclear Transformer Pressure Transmitter to provide a reliable solution for harsh environments. This electrical conduit connector has a clamp-on disconnect design, which makes it easy to ...
|
|
Rosemount/Rosemount Disposable Dissolved Oxygen Sensor Adapter 550DW Connector PG13.5
Description: The Rosemount/Rosemount Single-Use Dissolved Oxygen Sensor Adapter 550DW is compatible with standard stainless steel dissolved oxygen sensors and has been validated by the Rosemount Hx438 for use in single-use bags. The adapter is gamma irradiated to contact the process solution, which means that the sensing ...
|
|
Rosemount/Rosemount pH/ORP Sensor 398 Measuring range pH 0—14
Description: The Rosemount/Rosemount pH/ORP Sensor 398 features a Tefzel® and titanium chemically resistant construction and a patented TUpH™ reference wet, making it an ideal sensor for measuring the pH of demanding process liquids. This sensor is used to measure acid water strippers, ...
|
|
The Rosemount/Rosemount Radar Level Gauge 5900S ± 0.5mm accuracy
Introduction: The Rosemount/Rosemount Radar Level Gauge 5900S has an accuracy of ±0.5 mm (0.020 in.) to minimize level measurement uncertainty. It enhances ...
|
|
Rosemount/Rosemount In-Line Oxygen Analyzer 6888A Ambient temperature -40 to 70°C
Description: The Rosemount/Rosemount In-Line Oxygen Analyzer 6888A continuously and accurately measures the amount of oxygen in the flue gas of any combustion process. Accurate measurement of residual oxygen is critical to combustion reactions, reducing energy costs, improving safety, and reducing emissions. Rugged oxygen ...
|
|
Rosemount/Rosemount Fixed Gas Detector 925FGD
Introduction: The Rosemount/Rosemount Fixed Gas Detector 925FGD, the Rosemount 925FGD gas detector uses non-dispersive infrared (IR) technology to detect flammable gas leaks early in the process. As the first fixed gas detector designed by Rosemount, it features ...
|
|
Rosemount/Rosemount Three-Channel Transmitter 1057
Introduction: Rosemount/Rosemount Triple Transmitter 1057, 1057 Triple Input Analyzers provide pH/ORP/ISE or connected conductivity/resistivity inputs to the sensor. With unrestricted dual measurement options, you can reduce the cost per circuit and save panel space
Give birth...
|
|
Rosemount/Rosemount Sensor 3500P PERpH-X™ pH/ORP
Introduction: Rosemount/Rosemount Sensor 3500P PERpH-X™ pH/ORP, The Rosemount 3500P PERpH-X™ pH/ORP sensor incorporates innovative design technologies to extend the life of the sensor in harsh environment applications. Sensor's double hydraulic reference cell ...
|
|
Rosemount/Rosemount Level Transmitter 326L with an accuracy of 7mm
Description: The Rosemount/Rosemount Level Transmitter 326L provides accurate and continuous level measurement for the food and beverage industry. The transmitter is hygienically certified (3-A, FDA, EC 1935, etc.), has a polished stainless steel housing, supports cleaning-in-place, reduces the risk of contamination and ensures ...
|
|
Rosemount/Rosemount 848T Wireless Temperature Transmitter WirelessHART® protocol
Summary: The Rosemount 848T wireless temperature transmitter is the best choice for high-density measurements using WirelessHART® protocol devices. The transmitter accepts up to four independently configurable inputs, dramatically reducing the number of inputs per transmitter by using a smart, reliable, and secure wireless network.
|
|
Rosemount/Rosemount Flanged Vortex Flow Meter 8800DF030 with a turndown ratio of 38:01:00
Description: The Rosemount/Rosemount Flanged Vortex Flow Meter 8800DF030 eliminates potential leak points with a gasket-free, anti-clogging gauge body. Discrete sensors facilitate the replacement of flow and temperature sensors without damaging the process seal.
Features:
Isolated sensor design allows for ...
|
|
Rosemount/Rosemount Thin Plate Vortex Flow Meter 8800DW030
Description: The Rosemount/Rosemount Thin Plate Vortex Flow Meter 8800DW030 provides a cost-effective, lightweight alternative to flanged vortex flow meters. The compact, space-saving design is versatile and can be installed in any location.
Products...
|
|
Rosemount/Rosemount Nuclear Industry Certified Pressure Transmitter 3155K output signal 4-20mA
Description: The Rosemount/Rosemount Nuclear Industry Certified Pressure Transmitter 3155K provides accurate pressure measurement for nuclear industry applications. In addition, the transmitter can be operated in severe accident environments, with a long service life and reliable performance. This product is a durable solution that meets industry standards ...
|
|
Rosemount/Rosemount 214C Thermocouple Temperature Sensor 24AWG wire
Introduction: The Rosemount 214C thermocouple temperature sensor is an industry-standard sensor that maintains resilience and durability in harsh operating environments. The sensor is available in Type J, K, and T thermocouples that meet ASTM and IEC standards for thermocouple accuracy tolerances. The sensor is effective in high vibration ...
|
|
Rosemount/Rosemount Flow Meter 3051CFA Annubar™
Introduction: The Rosemount/Rosemount Flow Meter 3051CFA Annubar™, the Rosemount 3051CFA Annubar Flow Meter is an industry-leading flow measurement solution that uses a patented T-shaped average pitot tube to provide reliable accuracy across a wide flow range. Obtain...
|
|
Rosemount/Rosemount Controller 3493 Input: 4-20mA
Description: The Rosemount/Rosemount Controller 3493 provides control capabilities for any 4–20mA or HART-compatible transmitter. The backlit display clearly displays the measured values as well as the status of all inputs and outputs. Product development is customer-centric and utilizes easy-to-navigate menus.
|
|
Rosemount/Rosemount Level Transmitter 3302 Operating temperature -40—150°C
Description: The Rosemount/Rosemount Level Transmitter 3302 is used for level and interface measurements, providing a cost-effective and reliable solution for liquid applications. The Rosemount 3302 has no moving parts, requires no calibration, and is virtually unaffected by process conditions. With the help of the top ...
|
|
Rosemount/Rosemount Eight-Channel Gas Ultrasonic Flowmeter 3418
Introduction: Rosemount/Rosemount Eight-Channel Gas Ultrasonic Flowmeter 3418, the new Rosemount 3418 Eight-Channel Ultrasonic Flowmeter is manufactured, developed, and engineered by Emerson to deliver high accuracy and best-in-class performance with the high functionality required by precision legal-for-trade users. 3418 Flow Meter ...
|
|