Introduction: The Rosemount/Rosemount In-Line Oxygen Analysis Oxymitter™ 4000 is the world's first in-line zirconia oxygen analysis transmitter for flue gas measurement, up to explosion-proof level. These oxygen content measurements can be used in the control system or fine-tuned by the boiler operator to improve combustion efficiency by fine-tuning the fuel/air ratio of the burner based on these results.
Features:
Outstanding precision
The electronics can be mounted directly on the probe or separately
Xi advanced electronic components are available
Large backlit LCD display
Advanced software features
Wireless functionality - via THUM adapter
Accommodates any existing oxygen analysis probe installation
Advanced sensor diagnostics: Alarm indicates that the instrument needs to be calibrated
Optional explosion protection rating: See PDS 106-340.C01
HART® or FOUNDATION™ fieldbus digital communication: compatible with AMS/Plantweb®
Fully serviceable in the field
Variable probe insertion depth option
Product parameters
Response time: Up to 90 sec for T8
Process temperature range: up to 705°C (1300°F), 1050°C (1922°F) with optional bypass and jacket
Ambient temperature: -40 to 80 °C (-40 to 176 °F)
Size: Probe lengths range from 0.46 m (18 in) to 5.49 m (18 ft).
Communication protocols: 4-20 mA HART, FOUNDATION Fieldbus
Our customer-centric service concept: the pursuit of a full range of services is a high-quality, high-standard service, the pursuit of every detail of the service process. It is impossible for interests to blossom into brilliant flowers from lies. Only every process, every action, and every detail of the service can be professional and careful, in order to meet or even exceed customer expectations, so that customers are satisfied and recognize us. Honest, professional, affordable, fast, so let you rest assured." Integrity and professional service, affordable price, and continuous improvement" is our service concept.
This article introduces the Rosemount/Rosemount Oxymitter 4000 product, if you are interested in Rosemount/Rosemount Oxymitter™ 4000 product, please also contact our customer service, we look forward to your call, hope our technology and service can bring you a better experience.
|
More on that
|
The Rosemount/Rosemount Temperature Transmitter 644 outputs 4-20mA
Introduction: Rosemount/Rosemount Temperature Transmitter 644, the Rosemount 644 temperature transmitter is versatile and available using HART®, FOUNDATION™ fieldbus, or PROFIBUS® protocols, with top, field, or rail mounting styles and a variety of enclosure options. Pass...
|
|
Rosemount/Rosemount Liquid Ultrasonic Flow Meter USM381420 Pressure range 0 to 155 Bar
Introduction: The Rosemount/Rosemount Liquid Ultrasonic Flow Meter USM381420, a new custody transfer meter with excellent linearity over the flow range, further reducing product loss and unexplained loss. A new generation of electronics optimizes the operation of the flow meter, and the full-bore design ensures that the flow meter is ...
|
|
Rosemount/Rosemount Two-Channel Liquid Ultrasonic Flow Meter USM381212
Introduction: The Rosemount/Rosemount Two-Channel Liquid Ultrasonic Flow Meter USM381212, two-channel design, field-replaceable sensor, high accuracy and repeatability of measurement results, suitable for verification metering, distribution, leak detection, pipeline balancing, process measurement, and other non-trade transactions.
|
|
Rosemount/Rosemount Retractable Contact Conductivity Sensor 420VP
Introduction: Rosemount/Rosemount Retractable Contact Conductivity Sensor 420VP, with the Rosemount 402VP Retractable Conductivity Sensor, you will be able to accurately measure electrolytic conductivity in a wide range of applications, from high-purity water to cooled purified water. The Rosemount 400 sensor is non-...
|
|
Rosemount/Rosemount Carbon Monoxide Analyzer CCO 5500
Introduction: The Rosemount/Rosemount Carbon Monoxide Analyzer CCO 5500, the CCO 5500 Carbon Monoxide (CO) Analyzer uses infrared absorption spectroscopy to continuously measure the concentration of carbon monoxide in combustion flue gases. The infrared source is mounted directly on the flue gas duct or chimney on the opposite side of the receiver. Infrared...
|
|
Rosemount/Rosemount Liquid Ultrasonic Flow Meter USM381210
Description: The Rosemount/Rosemount Liquid Ultrasonic Flow Meter is a USM381210 two-channel design with field-replaceable sensors for accurate and repeatable measurements for verification metering, dispensing, leak detection, pipeline balancing, process measurement, and other non-legal-for-trade applications.
|
|
Rosemount/Rosemount Electromagnetic Flowmeter 8750W025 Caliber 0.15-8in
Description: The Rosemount/Rosemount Electromagnetic Flowmeter 8750W025, with its reliable, all-welded coil housing and lightweight sensor design (IP68 rating) ensures that the meter is compatible with all utility, water and wastewater applications. Certified for drinking water.
Product Features ...
|
|
Rosemount/Rosemount Conventional Manifold 304 90° Transmitter
Introduction: The Rosemount/Rosemount Conventional Manifold 304 is available in a combination of 2-, 3-, and 5-valve configurations and can be connected to the transmitter using conventional or collinar flanges. Available in conventional and clamp versions, the manifold is factory connected to the transmitter and leak tested, calibrated, and installed ...
|
|
The Rosemount/Rosemount plunger probes the discrete transmitter 702 in place
Introduction: The Rosemount/Rosemount Plunger in Place Probe Discrete Transmitter 702, the Rosemount 702 Plunger Probe Discrete Transmitter uses a plunger to improve the efficiency of natural gas well sites. The transmitter is used in conjunction with an existing plunger in place sensor to detect a buggy event and send back a ...
|
|
The Rosemount/Rosemount Transmitter 3153K outputs 4-20mA
Introduction: Rosemount/Rosemount Pressure Transmitter 3153K, Rosemount 3153K nuclear-certified pressure transmitter certified by Electricite de France to meet the needs of RCC-E K3 applications, this analog transmitter is designed for nuclear reactor operation in France. This device can ...
|
|
Rosemount/Rosemount Electromagnetic Sensor MS060 Accuracy±0.25%
Introduction: The Rosemount/Rosemount electromagnetic sensor MS060, MS slurry sensor is a reliable solution for difficult-to-measure applications such as grit, high solids fluids, long fiber slurries, or installations that generate excessive process noise. The MS slurry sensor is designed for difficult-to-measure...
|
|
Rosemount/Rosemount Conductivity Sensor 403 PUR-Sense™
Introduction: Rosemount/Rosemount Conductivity Sensor 403 PUR-Sense™, Rosemount 403 and 403VP sensors are primarily used to measure conductivity in water for injection (WFI). The sensor can also be used in water purification systems in the food and beverage industry.
Features:
...
|
|
Rosemount/Rosemount Liquid Ultrasonic Flow Meter USM381416 Pressure range 0 to 155 Bar
Introduction: The Rosemount/Rosemount Liquid Ultrasonic Flow Meter USM381416, a new custody-transfer meter with excellent linearity over the flow range, further reducing product loss and unspecified losses. A new generation of electronics optimizes the operation of the flow meter, and the full-bore design ensures that the flow meter is ...
|
|
The Rosemount/Rosemount pressure transmitter 3051 Coplanar™ has a turndown ratio of up to 150:1
Introduction: Rosemount/Rosemount Pressure Transmitter 3051 Coplanar, the Rosemount 3051 Coplanar™ Pressure Transmitter offers business-leading performance and patented technology for added user convenience.
Features:
Rosemount 3051 ...
|
|
Rosemount/Rosemount Graphic Field Display 2230 Ambient temperature -20 to 70 °C
Introduction: Rosemount/Rosemount Graphic Field Display 2230, Rosemount 2230 Graphic Field Display displays tank metering data such as level, temperature, pressure, and total observed volume. It provides all tank data directly in the field and offers different view options. ...
|
|
Rosemount/Rosemount Flanged Vortex Flow Meter 8800DF010 Turndown ratio 38:01:00
Description: The Rosemount/Rosemount Flanged Vortex Flow Meter 8800DF010 eliminates potential leak points with a gasket-free, anti-clogging gauge body. Discrete sensors facilitate the replacement of flow and temperature sensors without damaging the process seal.
Features:
Isolated sensor design allows for ...
|
|
Rosemount/Rosemount Thin Plate Vortex Flow Meter 8800DW040
Description: The Rosemount/Rosemount Thin Plate Vortex Flow Meter 8800DW040 provides a cost-effective, lightweight alternative to flanged vortex flow meters. The compact, space-saving design is versatile and can be installed in any location
Product Features ...
|
|
Rosemount/Rosemount Corrosion and Erosion Monitoring System Permasense ET410
Introduction: The Permasense ET410, a unique ultrasonic sensor that continuously measures pipe thickness and provides real-time insight into corrosion and erosion trends, is the Permasense ET410 corrosion and erosion monitoring system. The ET410 sensor system is a non-intrusive, battery-powered, fast...
|
|
Rosemount/Rosemount Transmitter 8782 Power supply 12—42VDC
Description: The Rosemount/Rosemount Transmitter 8782 is ideal for high-noise applications that require very high performance. The 8782 products use our latest advanced signal processing technology to stabilize otherwise noisy process flow signals without sacrificing responsiveness. Advanced Signal Division ...
|
|
Rosemount/Rosemount Toroidal Conductivity Sensor 228 stainless steel
Description: The Rosemount/Rosemount Toroidal Conductivity Sensor 228 performs well in high conductivity liquids up to 2S/cm (2,000,000uS/cm). These sensors can still function in dirty and corrosive environments where metal electrode sensors can fail. Reliable...
|
|