The impact of power quality problems on frequency converters - electricity production

Create Date: 2024-8-30 12:03:23|Source: LS/Power Generation

(1) Excessive voltage error will increase the loss of electrical equipment, shorten the life, and work abnormally, which will damage the stability of the synchronous operation of the power system, the stability of the voltage and the economic operation of the power grid, and will cause the inverter system to report overvoltage fault or undervoltage fault.

                               The impact of power quality problems on frequency converters - electricity production

(2) The fluctuation and flicker of the voltage are mainly caused by the shaking load, and its excess will endanger the equipment of other users connected to it at the public power supply point, such as making the motor speed uneven and the man-machine interface and electronic equipment working abnormally, which will lead to the inverter reporting overcurrent fault, driving fault, etc., as well as the phenomenon of man-machine interface crash or inaccurate monitoring interface voltage and current display.

(3) Harmonics are injected into the system by harmonic sources (nonlinear equipment and loads), which will affect the service life of power equipment, electrolytic capacitors, transformers, cables, voltage transformers, etc. in the system equipment, threaten the safe operation of the system, increase the power loss of the system, increase the error of measuring the appearance, and interfere with communication. The inverter system presents drive faults, overheating faults, optical fiber faults, etc. in operation.

(4) Three-phase unbalance will make the generator work abnormally, the additional loss of the addition of the transformer will cause its local overheating, the relay protection and automatic device will malfunction, the inverter will produce non-characteristic harmonics, the addition of neutral current will cause electrical noise interference, the loss of the transmission line will be added, and the communication will be interfered with. If the three-phase is severely unbalanced for a long time, it will also lead to severe burning of the three-phase cooling fan of the inverter system and the three-phase small transformer inside the power unit, and then lead to a series of problems such as overheating failure and optical fiber failure.

(5) When the power system is running stably, the whole system has the same frequency. Within the scale of the promised frequency error, it mainly causes the power problem of the inverter equipment; When the error exceeds the scale, it will endanger the safety of the inverter equipment, and even cause the system to collapse and collapse in severe cases.

(6) Temporary overvoltage and transient overvoltage, voltage drop and short-term power supply interruption will directly affect the normal operation of the inverter system, and generally cause overvoltage fault and undervoltage fault.
More on that
Features of LS SUSOL series circuit breakers Features of LS SUSOL series circuit breakers

Features of SUSOL series circuit breakers: It can be used as the main switch of electrical equipment, and the limit breaking ability is high, Icu=Ics Modular construction of circuit breakers: Tripper replacement (TS series) can be combined in a variety of combinations, such as ...

Types and characteristics of PLC digital output modules for power production Types and characteristics of PLC digital output modules for power production

  The main functions and functions of PLC: 1. For sequential control: sequential control is based on the current and pre-historical situation of the input switch, and produces the required switching output, so that the system can operate in a certain order. ...

Introduction of LS inverter IGXA series Introduction of LS inverter IGXA series

LS inverter, the full name of LS AC inverter governor, converts direct current into alternating current by providing a variety of use configurations, and controls the speed of the motor by changing the voltage and frequency of the general power input to meet different industrial needs, so as to complete the energy saving and environmental protection of the automation system. ...

Inverter failure and solution - power generation Inverter failure and solution - power generation

1. HW problem This problem may be a fault unique to LG-IG5 series inverters, and the main causes are as follows: (1) Damage to the cooling fan. Due to the use of environmental and other factors, the friction of the fan bearing is too large, causing the fan load to be too large and showing H ...

The torque of the inverter is directly used as the controlled quantity mode - LS generates electricity The torque of the inverter is directly used as the controlled quantity mode - LS generates electricity

VVVF frequency conversion, vector control frequency conversion, and direct torque control frequency conversion are all one of the AC-DC-AC frequency conversion. Its common disadvantages are low input power factor, large harmonic current, large demand for energy storage capacitors in DC circuits, and renewable energy can not be reflected back to the grid, that is, it cannot carry out four-quadrant operation.

The interference phenomenon of the inverter - LS power generation The interference phenomenon of the inverter - LS power generation

1. As soon as the inverter of the heat exchange station is opened, the pressure transmitter jumps randomly; 2. In the water supply controlled by the inverter, the pressure transformer is used as the signal to collect the pressure, and the pressure transformer is interfered by the inverter; 3. When the inverter starts the motor, the voltage transformer signal is unstable ...

Parameter setting of LS power inverter Parameter setting of LS power inverter

The inverter is a high-tech intelligent product, in order to let it complete the specified control mission, it must be set parameters, otherwise, it is like the computer is not installed and used, and it cannot be operated normally. The parameter setting is carried out by the control surface of the inverter. All kinds of inverters ...

Can an inverter replace a soft starter - LS generates electricity Can an inverter replace a soft starter - LS generates electricity

1. Soft start function The soft start function of the inverter is no longer necessary to talk about today, and twenty years ago, it was still a very exciting operation, which is also one of the auxiliary basic functions of the inverter. At the beginning of the birth of the inverter, it was aimed at the most widely used three-phase asynchronous squirrel cage ...

Introduction of LS electric power contactors Introduction of LS electric power contactors

How LS Contactor Works: Generally, after the contactor coil is energized, the entire coil current will generate a magnetic field, which will make the core inside have electromagnetic attraction to attract the core, and let their communication contactor point action normally closed contact disconnect, or close, which ...

The main functions and functions of LS power production PLC The main functions and functions of LS power production PLC

1. For sequential control: sequential control is based on the current and pre-historical conditions of the input switch, and produces the required switching output, so that the system can work in a certain order. This is the basic manipulation of the system. It is also a common manipulation in discrete production processes. ...

Introduction to the use of PLC for power production Introduction to the use of PLC for power production

1. It is used for switching control The ability of PLC to manipulate switching quantities is very strong. The number of points in and out of the control, less than a dozen points, dozens of points, more can be hundreds, thousands, or even tens of thousands of points, because it can be networked, the number of points is almost unlimited, no matter how many points can be controlled, the control ...

The internal accessories component of the power production circuit breaker The internal accessories component of the power production circuit breaker

1. Auxiliary contact: the contact mechanically linked with the main circuit of the circuit breaker and the closing mechanism is mainly used for the display of the circuit breaker and the closing status, and is connected to the control circuit of the circuit breaker through the opening and closing of the circuit breaker to control or interlock its related electrical appliances. For example, output to signal lights, relays, etc.

Asynchronous motor with inverter - LS generates electricity Asynchronous motor with inverter - LS generates electricity

Before the asynchronous motor is equipped with an inverter, let's take a look at the three major types of mechanical equipment loads: 1. Constant torque load: such as conveyor belts and mixers; When the inverter drags a load of constant torque nature, the torque at low speed should be large enough and the overload capacity should be large enough. If you need ...

Interference phenomenon of LS power inverter Interference phenomenon of LS power inverter

1. As soon as the inverter of the heat exchange station is opened, the pressure transmitter jumps randomly; 2. In the water supply controlled by the inverter, the pressure transformer is used as a signal to collect the pressure, and the pressure transformer is disturbed by the inverter; 3. When the inverter starts the motor, the voltage converter signal is unstable and beats violently; 4. Pressure transformer (4-20 ...

Introduction to the working principle of LS electric molded case circuit breaker Introduction to the working principle of LS electric molded case circuit breaker

Molded case circuit breakers are also known as equipment circuit breakers, all parts are sealed in plastic housings, auxiliary contacts, undervoltage trippers and shunt trippers are modular. Because of the very compact structure, the molded case circuit breaker is basically impossible to maintain. It is mostly manually operated, and the large capacity ...

Servo drives and servo motors – LS produces electricity Servo drives and servo motors – LS produces electricity

Driver: Under the premise of carrying out frequency conversion skills, the servo drive has carried out more advanced control skills and algorithm operations than general frequency conversion in the current ring, speed ring and azimuth ring inside the drive (the frequency converter does not have this ring), and it is much stronger than the traditional servo in terms of function.

What are the advantages of frequency conversion speed regulation - LS power production What are the advantages of frequency conversion speed regulation - LS power production

1. Outstanding frequency conversion speed regulation characteristics Completing the frequency conversion speed regulation of asynchronous motor is the "century wish" that people have been waiting for since the creation of asynchronous motor for 100 years. Through unremitting improvement, enhancement and perfection, the speed regulation function of VFD is not bad, that is, compared with the DC speed regulation system, the part ...

Introduction of LS PLC programming software Introduction of LS PLC programming software

LS PLC programming software is a professional PLC programming assistant tool, providing excellent interface, which can carry out PLC programming operations such as online modification, debugging and self-diagnosis, packing and debugging, etc., compatible with LG Master-K series and LG MASTER-K series, which can make you in the process of processing in a timely manner.

Basic introduction to transistors - LS produces electricity Basic introduction to transistors - LS produces electricity

A transistor is a solid-state semiconductor device with a variety of functions such as detection, rectification, amplification, switching, voltage regulation, and signal modulation. A transistor is a variable current switch that can manipulate the output current based on the input voltage. Unlike general mechanical switches (e.g. Relay, swit...)

The reason for the overload trip of the inverter - LS generates electricity The reason for the overload trip of the inverter - LS generates electricity

1. The load is too heavy, the load carried by the motor is too heavy, or in other words, the resistance torque of the production machinery exceeds the additional torque of the motor. 2. Use improper overload, for example, increase the operating frequency of the inverter to the extra frequency of the motor, and the motor is in the extra frequency.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top