Description: Rosemount/Rosemount Hygienic Electromagnetic Flowmeter Sensor 8721010 designed for food, beverage, and life science applications. All contact surfaces are manufactured using FDA-approved materials and are designed to meet 3A and EHEDG standards
Features:
Lightweight and compact stainless steel design for easy installation
With FDA-approved materials including EHEDG-certified 3-A surface treatment, it can be used to test Grade A milk
The all-welded instrument body design meets the safety of hygienic application scenarios
The sensors are CIP/SIP cleanable, with an inner diameter that matches the process piping and no step changes that are difficult to clean.
Equipped with a large number of hygienic process connectors available, it can meet the needs of almost any scenario
Easily accessible process gaskets make inspection and maintenance easier
Frictionless design, no need to maintain and repair any working parts, reduce costs and improve efficiency
Product parameters
Accuracy: Up to 0.25% volumetric flow accuracy at 13:1 flow range and 0.5% at 40:1 flow range
Pipe size: 1/2-4in (15-100mm)
Lining material: PFA
Electrode material: 316L stainless steel, Hastelloy, platinum
Process connections: Tri-Clamp® sanitary fittings IDF sanitary fittings (spiral) welded stubs DIN 11851 (Imperial and metric) DIN 11864 (-1 and -2 Type A) SMS 1145 DEN US 50 welded stubs
Product certification: 3-A, EHEDG Type EL, PMO (M-b-350)
Our customer-centric service concept: the pursuit of a full range of services is a high-quality, high-standard service, the pursuit of every detail of the service process. It is impossible for interests to blossom into brilliant flowers from lies. Only every process, every action, and every detail of the service can be professional and careful, in order to meet or even exceed customer expectations, so that customers are satisfied and recognize us. Honest, professional, affordable, fast, so let you rest assured." Integrity and professional service, affordable price, and continuous improvement" is our service concept.
This article introduces the 8721010 products of Rosemount/Rosemount Sanitary Electromagnetic Flowmeter Sensor, if you are interested in Rosemount/Rosemount Sensor, please also contact our customer service, we look forward to your call, hope our technology and service can bring you a better experience.
|
More on that
|
Rosemount/Rosemount pH/ORP Sensor RBI Measurement Range 0-14
Summary: RBI pH sensors are designed to last longer than typical sensors in applications containing sulfides (typically found in scrubbing units).
Features:
The unique multi-liquid reference electrode design prevents contamination of the reference electrode and extends the sensor's ...
|
|
Rosemount/Rosemount Tank Radar Level Gauge TGU 65 Baseline Accuracy ±2mm
Introduction: The Rosemount/Rosemount Tank Radar Level Gauge TGU 65 provides the performance needed to obtain accurate draft and level readings for narrow sludge tanks. The Rosemount TGU 65 Tank Radar Level Gauge is designed for long-term performance in harsh conditions. 10 GHz FMCW Array ...
|
|
Rosemount/Rosemount 397 TUpH™ pH/ORP sensor
Introduction: Rosemount/Rosemount 397 TUpH™ pH/ORP Sensor, the low-maintenance Rosemount 397 pH/ORP sensor provides pH and ORP measurements in aqueous solutions containing large amounts of suspended solids for long lifetime and high performance.
...
|
|
Rosemount/Rosemount Primary Sonic Gas Ultrasonic Flowmeter USM341220
Introduction: Rosemount/Rosemount primary sonic gas ultrasonic flowmeters are USM341220 for non-legal-for-trade metering of natural gas, such as verification metering, pipeline balancing, storage measurement, production or moisture metering. Featuring Mark III electronics and two-channel measurement redundancy.
...
|
|
Rosemount/Rosemount Advanced Sonic Gas Ultrasonic Flow Meter USM341720
Description: The Rosemount/Rosemount Advanced Sonic Gas Ultrasonic Flow Meter USM341720 that leverages the power of a field-proven, United Kingdom-designed Rosemount quad string meter (OIML R137 1&2 accuracy class 0.5) designed by Towngas, combined with ...
|
|
Rosemount/Rosemount Electromagnetic Flowmeter Sensor 8721030 Tubing Sizes 15-100mm
Description: Rosemount/Rosemount electromagnetic flowmeter sensor 8721030 designed for food, beverage, and life sciences applications. All contact surfaces are manufactured using FDA-approved materials and are designed to meet 3A and EHEDG standards.
Features:
Lightweight and compact ...
|
|
Rosemount Quad Vortex Flow Meter 8800DQ060 outputs 4-20mA
Description: The Rosemount/Rosemount Quad Vortex Flow Meter 8800DQ060 with a fourth integrated transmitter for process control provides the ultimate redundant flow measurement solution to prevent false trips with a two-of-three vote. The 8800 Quad Vortex Flowmeter has an out...
|
|
Rosemount/Rosemount Multi-Instrument Flange MIF-61 Accuracy±2mm
Introduction: Rosemount/Rosemount Multi-Instrument Flange MIF-61, in order to meet regulations regarding emissions, many ships are transitioning to liquefied natural gas (LNG) or liquefied petroleum gas (LPG) as their primary fuel source due to low sulfur emissions. However, this shift has given ...
|
|
Rosemount/Rosemount 2410 Tank Hub
Introduction: Rosemount/Rosemount 2410 Tank Hub, the Rosemount 2410 handles data communication between field devices and the control room and is available in single and multi-tank versions. Control room communication options include Modbus, IEC 62591 (WirelessHART® protocol) ...
|
|
Rosemount/Rosemount 148 Temperature Transmitter 4-20mA Simulation
Summary: The Rosemount 148 temperature transmitter is a standard unit that can be used with a variety of sensor type inputs and can be cost-effectively installed with higher measurement accuracy than direct-wire solutions. The transmitter is available in a DIN B top-mount configuration and has a ...
|
|
Rosemount/Rosemount Liquid Ultrasonic Flow Meter USM381406 Pressure range 0 – 155 Bar
Description: The Rosemount/Rosemount Liquid Ultrasonic Flow Meter USM381406, a new custody transfer meter with excellent linearity over the flow range, further reducing product loss and unspecified loss. A new generation of electronics optimizes the operation of the flow meter, and the full-bore design ensures that the flow meter is ...
|
|
Rosemount/Rosemount Explosion Proof Transmitter 5081 Power Supply 12VDC
Introduction: Rosemount/Rosemount Explosion Proof Transmitter 5081, the Rosemount 5081 Explosion Proof Transmitter is a single-channel loop-powered device that can receive pH/ORP sensors, conductivity sensors (contact and ring) sensors, and amperometers (dissolved oxygen, chlorine, and ozone sensors).
|
|
Rosemount/Rosemount Electromagnetic Flowmeter 8750W025 Caliber 0.15-8in
Description: The Rosemount/Rosemount Electromagnetic Flowmeter 8750W025, with its reliable, all-welded coil housing and lightweight sensor design (IP68 rating) ensures that the meter is compatible with all utility, water and wastewater applications. Certified for drinking water.
Product Features ...
|
|
Rosemount/Rosemount Slurry Electromagnetic Flowmeter Sensor 8705080 15-900mm diameter
Introduction: The Rosemount/Rosemount Slurry Electromagnetic Flowmeter sensor is 8705080, with an all-welded construction that provides an airtight port for moisture and contaminant protection, while the junction box is removable and replaceable for easy field service.
Features:
For maximum protection ...
|
|
Rosemount/Rosemount Clamp-on Electromagnetic Flowmeter Sensor 8711040
Introduction: The Rosemount/Rosemount Clip-on Electromagnetic Flowmeter sensor 8711040 provides a compact, lightweight alternative to flanged magnetic flowmeters. Alignment gasket kit for easy installation.
Features:
Flange structure, dimensions and ...
|
|
Rosemount/Rosemount Conventional Manifold 304 90° Transmitter
Introduction: The Rosemount/Rosemount Conventional Manifold 304 is available in a combination of 2-, 3-, and 5-valve configurations and can be connected to the transmitter using conventional or collinar flanges. Available in conventional and clamp versions, the manifold is factory connected to the transmitter and leak tested, calibrated, and installed ...
|
|
Rosemount/Rosemount General Purpose pH/ORP Sensor 389
Introduction: Rosemount/Rosemount General Purpose pH/ORP Sensor 389, The Rosemount 389 pH/ORP sensor with integrated cable uses a molded Tefzel™ body and Viton™ O-rings to make it extremely difficult to damage and highly chemically resistant. Encapsulation eliminates the need for additional pH/O ...
|
|
Rosemount/Rosemount Level and Flow Transmitter 1408A Communication Protocol: 4-20mA
Introduction: Rosemount/Rosemount Level & Flow Transmitter 1408A, The Rosemount 1408A Level Transmitter provides reliable, continuous level measurement. The radar enables excellent surface tracking, accurate level measurement, and open channel flow calculations. With a compact design and open-air certification ...
|
|
The Rosemount/Rosemount Hygienic Pressure Transmitter 2051HT offers a turndown ratio of up to 50:1
Introduction: The Rosemount/Rosemount Hygienic Pressure Transmitter 2051HT provides a reliable solution for gauge and absolute pressure measurements in the life sciences and food and beverage industries. The transmitter features Emerson's reliable pressure sensor technology and industry-standard process connections ...
|
|
Rosemount/Rosemount High Performance pH & ORP Sensor 3300HTVP
Introduction: Rosemount/Rosemount High Performance pH and ORP Sensor 3300HTVP, Rosemount 3300HTVP PERpH-X High Performance pH/ORP Sensor is designed to be durable and can significantly extend the life of the sensor in a variety of complex applications. This retrofittable sensor is used in high ...
|
|