ifm IO-Link devices are the inputs and outputs of the master modules

Create Date: 2024-8-30 12:03:23|Source: IFM/ifm

The new IO-Link I/O modules make it easy and cost-effective to add robust digital inputs and outputs to ifm's IO-Link master modules for use in the field.

                                  ifm IO-Link devices are the inputs and outputs of the master modules

●Through IO-Link and binary signal acquisition, the distributed switching digital output is completed

● Add up to 20 digital inputs and outputs to the IO-Link master module

●It is suitable for industrial use and can be supplied with new types for hygienic environments

●The output current of each power channel is up to 1.8A

●The input signal is preprocessed by the digital input filter

Inputs and outputs are switched decentrally via IO-Link

Typical missions include distributed switching of loads and actuators, or acquisition and processing of digital signals. For this purpose, the device has six or ten M12 ports, each with two digital inputs or outputs.

use

The module is available in two designs: the orange field module of the Cooling Resistant Series is oil and coolant resistant and is suitable for general industrial use. Thanks to the special housing material, the grey modules are ideal for hygiene and food use. It has a degree of protection up to IP 68 / IP 69K.

Input module

These modules can interface with up to 20 conventional sensors. With the unshielded M12 connection cable, IO-Link transmits signals to any IO-Link master or PLC. A special feature of the module is that the input signal can be pre-processed by different filters before it is transmitted via IO-Link. The filters that can be used include: denoising filter (pressing the noise signal), stretching filter (lengthening the signal), and inverting filter. This ensures reliable detection of signals with a minimum length of 1.5 ms.

The distributed arrangement of the modules reduces cabling costs and eliminates the need for messy cabling wiring. In contrast to bus architectures, IO-Link does not require any equipment or addressing, thus simplifying the installation. Pins 2 and 4 of each M12 socket are equipped as binary inputs. As a result, dual sensors can be connected without any problems. The inputs are fully protected against overload and short circuits.

Output module

The output is powered by two independent electrically blocked power supplies. The M12 socket on the left is powered by pins 1 and 3 of the power plug, and the M12 socket on the right is powered by pins 2 and 4. Both power supplies can support a maximum 1.8A load. The output current is distributed to the output according to the connected load, and the total current per channel is limited to 1.8A.
More on that
Precautions for the selection of level transmitters – ifm Precautions for the selection of level transmitters – ifm

The differential pressure transmitter is a transmitter that measures the pressure difference between the two ends of the transmitter, and outputs a standard signal (such as 4-20mA, 1-5V). The difference between the differential pressure transmitter and the general pressure transmitter is that they have 2 pressure interfaces, and the differential pressure transmitter is generally divided into positive pressure end and negative pressure end.

IFM M12 DC Connectors & Cables Features: IFM M12 DC Connectors & Cables Features:

IFM M12M12 DC connectors and cables ·“ OK in place" coupling nuts to withstand intense vibrations and shocks Damage to fluoroelastomer o-rings caused by over-tightening can be avoided · Construction data, tested ...

Tips for setting CAN parameters for ifm controllers Tips for setting CAN parameters for ifm controllers

1. ifm controller CAN parameters: communication cycle In some applications, it is possible to set the monitoring time for SYNC packets generated by the master here. Note that this moment is larger than the SYNC moment of the master. To go through the experiment ...

Attention to the selection of industrial sensors – ifm Attention to the selection of industrial sensors – ifm

1. According to the measurement object and measurement environment In order to carry out a detailed measurement operation, it is necessary to consider the principle of the sensor first, which needs to analyze many factors before confirmation. Because, even if the same physical quantity is measured, there are sensors with multiple principles to choose from.

Steps to install a dynamic torque sensor – ifm Steps to install a dynamic torque sensor – ifm

1. According to the connection form of the shaft and the length of the dynamic torque sensor, confirm the interval between the prime mover and the load, adjust the separation of the axis of the prime mover and the load relative to the reference plane, so that the coaxiality of their axis is less than Φ 0.03mm, and fix the prime mover and the load on the reference plane. ...

How ifm inductive sensors work How ifm inductive sensors work

How an inductive sensor works: An inductive sensor consists of three parts: an oscillator, a switching circuit, and an amplified output circuit. The oscillator produces an alternating magnetic field. When a metal target approaches this magnetic field and reaches the sensing distance, eddy currents are generated within the metal target, resulting in ...

Take you to know the proximity sensor - ifm Take you to know the proximity sensor - ifm

Proximity sensor is a general term for sensors that replace touch detection systems such as limit switches and aim at detecting objects without touching them. It converts the moving and possessive messages of the detected target into electrical signals. ...

The access point for load cell dashboards – ifm The access point for load cell dashboards – ifm

Key points of maintenance of electronic crane scales, automobile weighbridges, electronic forklift scales, unique effect electronic scales, and the outer dial of Dongguan electronic weighbridge weight sensor: The detection and analysis of problems in the application of load cells, and the common problems of the weighing appearance of automation technology have been in the end of the system software.

Selection rules for pressure transmitters Selection rules for pressure transmitters

Pressure transmitter is the most commonly used sensor in industrial practice, which is widely used in various industrial automatic control environments, touching water conservancy and hydropower, railway transportation, intelligent buildings, production automation, aerospace, military industry, petrochemical, oil wells, electric power, ships, machine tools, pipelines and many other occupations. ...

The difference between ifm inductive and capacitive sensors The difference between ifm inductive and capacitive sensors

There are many different series under ifm sensors, including inductive and capacitive sensors. So what's the difference between the two sensors? ifm inductive sensors are essential in industrial use.

Quality monitoring via the Y-link of ifm Quality monitoring via the Y-link of ifm

Through selective data collection on your machine, you are able to increase the overall power of your machine. DISPLAYS THE ACTUAL VALUE OF THE DEVICE'S PERFORMANCE AND HAS BEEN OPTIMIZED BY THE LINERECORDER MODULE MDE. Possibility of use: ...

The reason why the measurement results of the dynamic torque sensor do not match the accuracy – ifm The reason why the measurement results of the dynamic torque sensor do not match the accuracy – ifm

In the motor test system, the measurement of torque is often achieved by dynamic torque sensors. The motor under test is connected to the dynamic torque sensor through the coupling, and the other end of the sensor is connected to the load motor through the coupling. When the system is operating, the motor under test is operating in the speed ring ...

Moisture-proof method for sensors – ifm Moisture-proof method for sensors – ifm

As an accurate detection device, if the sensor is damp, it will be troublesome, the sensor will affect its accuracy and stability when it is damp, and it will form a problem if the sensor is used in a more important place, then the loss of the formation is very heavy. In '08 there was a ...

Structural classification of UV sensors Structural classification of UV sensors

1. Spherical cathode structure: In order to fully avoid the tip effect and make the photoelectron emission more stable and uniform, it is necessary to fix the operating area on the cathode, because the ultraviolet tube relies on photoelectron emission and gas multiplication to complete the conversion of the optical signal into an electrical signal and amplify it.

Common faults and maintenance methods of IFM pressure sensors Common faults and maintenance methods of IFM pressure sensors

1. When the pressure goes up, the output of the transmitter can't go up In this case, you should first check whether the pressure interface is leaking or blocked, if you confess that it is not, check the wiring method and check the power supply, if the power supply is normal, then briefly pressurize ...

Introducing the ifm flow sensor SI5000 Introducing the ifm flow sensor SI5000

ifm, a multinational conglomerate that has been researching, producing and selling components and systems for signal detection, control and processing on a global scale for more than 30 years, attended the 2007 Beijing FA/PA and brought their latest flow sensor S...

Features of fibre optic sensors – ifm Features of fibre optic sensors – ifm

1. High degree of activity; 2. A few shapes have multi-faceted adaptability, and can be made into arbitrary shape of optical fiber sensors; 3. It can manufacture devices that sense various physical information (sound, magnetism, temperature, rotation, etc.); 4. It can be used for high voltage, electrical noise, ...

Current sensor features – ifm Current sensor features – ifm

1. High sensitivity. The strength of the detected signal is getting weaker and weaker, which requires a significant increase in the sensitivity of magnetic sensors. The use includes current sensors, angle sensors, gear sensors, and space environment measurement. 2、 ...

The difference between fiber optic sensors and photoelectric sensors – ifm The difference between fiber optic sensors and photoelectric sensors – ifm

Optical fiber sensors and photoelectric sensors are two typical sensors, which are widely used in production and measurement, so what is the difference between the two? Next, we will analyze the differences between the two from the perspective of principle and use. ...

The criterion for judging vibration sensors – ifm The criterion for judging vibration sensors – ifm

1. The size of the measured oscillation; 2. The frequency scale of the oscillating signal; 3. The environment of the oscillation test site; 1) Selection and measurement scale of the sensitivity of the oscillation sensor Estimating the amount of oscillation will help ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top